Comparison of Two Rotational Alignment Methods for Astigmatism Correction in SMILE Surgery
NCT07696468 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 52
Last updated 2026-07-15
Summary
Small incision lenticule extraction (SMILE) is a commonly used corneal refractive procedure for correcting myopia and myopic astigmatism. During astigmatism correction, eye rotation between the upright examination position and the supine surgical position may affect the alignment of the astigmatic treatment axis and may contribute to residual astigmatism after surgery.
Manual limbal marking is a commonly used method to guide cyclotorsion adjustment during refractive surgery. OcuLign is an assisted cyclotorsion control function of the VISUMAX 800 platform that helps identify ocular rotation and guide axis alignment during SMILE. However, direct clinical evidence comparing OcuLign-assisted cyclotorsion control with manual limbal marking during SMILE is limited.
This study is a single-center, prospective, randomized, masked, contralateral-eye non-inferiority trial. Adults aged 18 to 40 years with stable myopia and astigmatism who plan to undergo bilateral SMILE surgery will be enrolled. In each participant, one eye will receive SMILE with OcuLign-assisted cyclotorsion control, and the fellow eye will receive SMILE with manual limbal marking-guided cyclotorsion adjustment. The treatment assigned to the right eye will be determined by randomization.
The primary objective is to compare residual refractive astigmatism at 3 months after surgery between the two methods. Secondary outcomes include visual acuity, refractive predictability and stability, astigmatism vector analysis, higher-order aberrations, contrast sensitivity, patient-reported quality of vision, overall satisfaction, and safety outcomes. Participants will be followed for approximately 6 months after surgery.
Conditions
- Myopia
- Refractive Ametropia
Interventions
- PROCEDURE
-
Device-assisted cyclotorsion control during SMILE
One eye of each participant will undergo SMILE using device-assisted cyclotorsion control with the OcuLign function of the VISUMAX 800 platform. During surgery, OcuLign will assist in identifying ocular rotation and guiding astigmatic axis alignment. Apart from the cyclotorsion adjustment method, the surgical parameters, lenticule design, suction procedure, postoperative medication, and follow-up schedule will be the same as those used for the fellow eye.
- PROCEDURE
-
Manual limbal marking-guided cyclotorsion adjustment during SMILE
The fellow eye of each participant will undergo SMILE using manual limbal marking-guided cyclotorsion adjustment. Limbal reference marks will be made in the upright preoperative position, and intraoperative axis alignment will be manually adjusted according to the limbal marks and the surgical reference direction. Apart from the cyclotorsion adjustment method, the surgical parameters, surgical procedure, postoperative medication, and follow-up schedule will be the same as those used for the contralateral eye.
Sponsors & Collaborators
-
Zhongshan Ophthalmic Center, Sun Yat-sen University
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- DOUBLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 40 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2026-07-13
- Primary Completion
- 2027-06-30
- Completion
- 2027-06-30
Countries
- China
Study Locations
More Related Trials
-
Evaluation of the Rotational Stability of The AcrySof Toric Intraocular Lens in the Capsular Bag in High Myopic Subjects
NCT01351233 ·Status: COMPLETED ·Phase: NA
-
Refractive Accuracy of Toric Intraocular Lens Implantation Using Digital Marking Compared to Conventional Marking
NCT07176897 ·Status: COMPLETED
-
A Randomized Controlled Trial Comparing Clinical Effectiveness of SMILE Versus SMILE Xtra in Myopia
NCT06992011 ·Status: RECRUITING ·Phase: NA
-
A Study of Artificial Intelligence Assisted Small Incision Lenticule Extraction (SMILE) for Surgical Design and Influencing Factors
NCT06229301 ·Status: RECRUITING
-
Comparison Between TICL and ICL+AK for High Myopic Astigmatism
NCT03202485 ·Status: COMPLETED ·Phase: NA
-
Comparison of Femto LDV Z8 Corneal Lenticule Extraction for Advanced Refractive Correction (CLEAR) and Visumax Small Incision Lenticule Extraction (SMILE)
NCT06774651 ·Status: RECRUITING
-
Randomized, Prospective Comparison of the Outcome of Toric Implantable Contact Lens (TICL) and Q-LASIK for the Correction of Myopia With Astigmatism
NCT01088568 ·Status: UNKNOWN ·Phase: NA
-
Influence of Different Toric Intraocular Lenses on IOL-capsular Complex
NCT05263518 ·Status: UNKNOWN ·Phase: NA
-
A Comprehensive Assessment of Anterior Corneal Power by Different Devices
NCT01587287 ·Status: COMPLETED
-
Comparison of the Effect of Capsular Bend on the Rotational Stability Between Two Toric Intraocular Lenses
NCT06707740 ·Status: ACTIVE_NOT_RECRUITING
-
Evaluation of Toric Intraocular Lens(IOL) Combined With Capsular Tension Ring(CTR) in Patients With Cataract Combined With High Myopia
NCT06571773 ·Status: ACTIVE_NOT_RECRUITING
-
SMILE Surgery in One Eye Compared to Ray Tracing-guided LASIK Surgery in the Fellow Eye
NCT07721714 ·Status: RECRUITING ·Phase: PHASE4
-
Rayner Toric IOL Rotational Stability
NCT02393313 ·Status: UNKNOWN ·Phase: NA
-
Comparison of Pre-operative Measurements With Intraoperative Aberrometry in Predicting Correction for Low Toric Lens Correction in Cataract Surgery
NCT04247152 ·Status: COMPLETED ·Phase: NA
-
Effectiveness and Safety of Limbal Relaxing Incisions for Correcting Post Phacoemulsification High Astigmatism
NCT06896357 ·Status: NOT_YET_RECRUITING ·Phase: PHASE1
-
SMILE vs. LASIK Using Contoura With Phorcides
NCT05844397 ·Status: COMPLETED ·Phase: NA
-
Effect of Different Needle Insertion Positions on the Clinical Outcomes of YAMANE Technique
NCT07446829 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
A Three-Phase Contralateral Comparison of Ray-Tracing Guided LASIK Versus Three Other Refractive Surgery Platforms to Correct Myopia or Myopia With Astigmatism
NCT07201298 ·Status: RECRUITING ·Phase: NA
-
Machine Learning Prediction of 1-Year Refractive Error After SMILE
NCT07478419 ·Status: COMPLETED
-
Clinical Study of SMILE 4.0-VISULYZE in Correcting Refractive Errors
NCT06982807 ·Status: RECRUITING ·Phase: NA
-
A Comparison of Corneal Aberrations in Subjects With Contralateral AcrySof IQ Toric Intraocular Lens (IOL) and AcrySof IQ IOL With Limbal Relaxing Incision (LRI)
NCT01045733 ·Status: COMPLETED ·Phase: NA
-
An Evaluation of LASIK, SMILE and PRK Surgery in Physicians
NCT02576483 ·Status: RECRUITING
-
A 2-year Longitudinal Study on the Structural and Optical Effects of Orthokeratology Treatment on Eye
NCT02643342 ·Status: COMPLETED ·Phase: NA
-
Clinical Evaluation of Toric Intraocular Lens
NCT03242486 ·Status: COMPLETED ·Phase: NA
-
Reduction of Corneal Astigmatism With Toric Intraocular Lens Implantation in Congenital Cataract
NCT02040129 ·Status: COMPLETED ·Phase: NA