SMILE vs. LASIK Using Contoura With Phorcides
NCT05844397 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 56
Last updated 2025-02-27
Summary
Subjects will undergo SMILE surgery in one eye and LASIK using Contoura with Phorcides on the contralateral eye to correct myopia.
Conditions
- Myopia
- Astigmatism
Interventions
- DEVICE
-
WaveLight EX500 Excimer Laser System
LASIK Refractive Surgery Using Contura with Phorcides
- DEVICE
-
VisuMax Surgical Laser
SMILE Refractive Surgery
Sponsors & Collaborators
-
59th Medical Wing
lead FED
Principal Investigators
-
Charisma B Evangelista, MD · 59th Medical Wing
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 21 Years
- Max Age
- 50 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2023-05-09
- Primary Completion
- 2024-05-14
- Completion
- 2024-05-14
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Patient Reported Satisfaction With Contoura LASIK Utilizing the Phorcides Analytic Software
NCT05848817 ·Status: COMPLETED
-
SMILE (Small Incision Lenticule Extraction) in the DoD (Department of Defense)
NCT04072289 ·Status: UNKNOWN ·Phase: NA
-
Contoura With Phorcides Compared to Wavefront Optimized LASIK
NCT05486546 ·Status: RECRUITING ·Phase: NA
-
Patient Reported Outcomes With WaveLight Plus LASIK
NCT07084844 ·Status: RECRUITING
-
Patient Reported Outcomes With WaveLight LASIK
NCT06668909 ·Status: COMPLETED
-
Comparison of Contoura Vision Outcomes Programmed Using the Manifest Refraction Verses Using Phorcides Planning Software in Patients With Oblique Astigmatism
NCT05888337 ·Status: TERMINATED
-
Contralateral Comparison of Three Excimer Laser Systems in Performing LASIK
NCT00821236 ·Status: COMPLETED ·Phase: PHASE4
-
Using the VisuMax Femtosecond Laser System to Perform SMILE Optimized for Presbyopia by Modulation of Postoperative Spherical Aberration
NCT05684237 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Clinical Results of Small Incision Lenticule Extraction (SMILE) for the Correction of High Myopia
NCT04110067 ·Status: RECRUITING
-
Clinical Investigation of the WaveLight® EX500 Excimer Laser
NCT04805593 ·Status: COMPLETED ·Phase: NA
-
Prospective Clinical Trial of the LensAR Laser System
NCT01014702 ·Status: UNKNOWN ·Phase: PHASE2/PHASE3
-
Visual Outcomes and Contrast Sensitivity After Myopic LASIK
NCT01746589 ·Status: COMPLETED ·Phase: PHASE4
-
Wavefront-guided LASIK Surgery Compared to Ray Tracing-Guided LASIK Surgery
NCT07078799 ·Status: RECRUITING ·Phase: NA
-
Customized Laser Ablation: Comparing Results of LADAR Vision and VISX Platforms
NCT00344838 ·Status: COMPLETED
-
Clinical and Refractive Outcomes After Contoura® Refractive Surgery Planned Using Phorcides Surgery Planning Software
NCT04495829 ·Status: COMPLETED
-
Association Between ORA and Residual Refractive Astigmatism After SMILE
NCT05604872 ·Status: COMPLETED
-
Evaluation of Toric Soft Contact Lenses Containing a Chromophore to Block High-Energy Visible Light
NCT05344560 ·Status: COMPLETED ·Phase: NA
-
Corneal Flap Thickness Planed vs Measured After LASIK by Using Tree Different Systems Cut
NCT00558324 ·Status: TERMINATED ·Phase: NA
-
Evaluation of Visual Outcomes of Monovision Patients Bilaterally Implanted With Nanoflex Intraocular Lenses
NCT01279122 ·Status: UNKNOWN ·Phase: PHASE4
-
Comparison of Clinical Outcomes of Small-incision Lenticule Extraction (SMILE) Between Different Cap Thickness.
NCT03584555 ·Status: COMPLETED ·Phase: NA
-
Patient Satisfaction With Contoura Vision Topography-Guided LASIK
NCT04903301 ·Status: COMPLETED ·Phase: NA
-
Contralateral Study of Topography Guided LASIK Versus Small Incision Lenticule Extraction
NCT05611294 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
An Evaluation of Outcomes Following Wavefront Optimized or Wavefront Guided Lasik Procedure in Low to Moderate Myopic Patients
NCT01173198 ·Status: COMPLETED ·Phase: PHASE4
-
WaveLight® Refractive Myopic Study
NCT01941498 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Visual Acuity of the Envista One-piece Acrylic Toric IOL MX60ET
NCT05739656 ·Status: COMPLETED