Randomized Cross-Over Comparison of Medium Cut-Off and High-Flux Hemodialysis Membranes
NCT07679763 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 30
Last updated 2026-07-01
Summary
Patients receiving maintenance hemodialysis are at increased risk of cardiovascular disease, chronic inflammation, endothelial dysfunction, and impaired quality of life. Medium cut-Off (MCO) hemodialysis membranes have been developed to enhance the removal of middle-molecular-weight uremic toxins compared with conventional high-flux membranes, which may improve inflammatory status and cardiovascular health.
The aim of this study is to compare the effects of MCO and high-flux hemodialysis membranes on inflammatory biomarkers and cardiovascular function in adult patients receiving maintenance hemodialysis. The primary outcomes are changes in serum interleukin-6 (IL-6) and vascular cell adhesion molecule-1 (VCAM-1) levels. Secondary outcomes include arterial stiffness assessed by pulse wave velocity (PWV), body composition assessed by Body Composition Monitor (BCM), handgrip strength, and patient-reported outcomes including quality of life, pruritus, and pain scores.
This is a prospective, randomized, open-label, two-sequence, two-period crossover study conducted at Gazi University Faculty of Medicine. Thirty adult hemodialysis patients will be randomized to one of two treatment sequences. Participants in Sequence A will receive MCO dialysis membranes for the first 3 months followed by high-flux membranes for the next 3 months. Participants in Sequence B will receive high-flux membranes for the first 3 months followed by MCO membranes for the next 3 months. Blood samples and clinical assessments will be performed at baseline, month 3, and month 6.
The study is expected to provide evidence regarding the effects of different dialysis membrane technologies on inflammation and cardiovascular health and may contribute to optimizing membrane selection in routine hemodialysis practice.
Conditions
- End Stage Kidney Disease (ESKD)
- Hemodialysis
- Cardiovascular Diseases (CVD)
- Inflammation
Interventions
- DEVICE
-
Medium Cut-Off Hemodialysis Membrane
Medium cut-off (MCO) hemodialysis membrane used as part of routine maintenance hemodialysis treatment. MCO membranes are designed to enhance the clearance of larger middle-molecular-weight uremic toxins while maintaining clinically acceptable albumin retention. Participants assigned to MCO treatment periods will receive thrice-weekly hemodialysis according to standard clinical practice. In this study, MCO treatment will be delivered using the ELISIO™ MCO series (Nipro).
- DEVICE
-
High-Flux Hemodialysis Membrane
High-flux hemodialysis membrane used as part of routine maintenance hemodialysis treatment. High-flux membranes represent the current standard dialysis technology and provide effective clearance of small solutes and selected middle molecules. Participants assigned to high-flux treatment periods will receive thrice-weekly hemodialysis according to standard clinical practice. In this study, high-flux treatment will be delivered using the ELISIO™ HF series (Nipro).
Sponsors & Collaborators
-
Nipro Medical Corporation
collaborator INDUSTRY -
Gazi University
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- CROSSOVER
Eligibility
- Min Age
- 18 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2026-07-31
- Primary Completion
- 2027-01-31
- Completion
- 2027-01-31
Countries
- Turkey (Türkiye)
Study Locations
More Related Trials
-
12 Weeks of Hemodialysis With Medium Cut-Off Filter Compared to Hemodiafiltration With Standard High-flux Filter.
NCT03416192 ·Status: WITHDRAWN ·Phase: NA
-
The Effect of Combining Medium Cut Off Dialysis Membrane and Diet Modification on Reducing of Inflammation Response
NCT04260412 ·Status: UNKNOWN ·Phase: NA
-
Combination of Medium Cut-off Dialyzer Membrane and Diet Modification to Alleviate Residual Uremic Syndrome of Dialysis Patients
NCT04247867 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of Biocompatibility and Performances of 4 Dialyzers in Different Mode Treatments
NCT03262272 ·Status: COMPLETED ·Phase: NA
-
A Comparative Study of Two Kinds of Hemodialysis Filters
NCT05899283 ·Status: COMPLETED ·Phase: NA
-
Cardiovascular and Bone Mineral Markers in Dialysis Patients and Healthy Controls
NCT07686978 ·Status: NOT_YET_RECRUITING
-
Effect of Nephral 400 ST Dialysis Membrane on Coagulation in Hemodialysis
NCT00594607 ·Status: COMPLETED ·Phase: NA
-
Effect of Dialysis Dose and Membrane Flux in Maintenance Hemodialysis
NCT00004285 ·Status: COMPLETED ·Phase: NA
-
Continuous Hemodialysis With an Enhanced Middle Molecule Clearance Membrane
NCT01067313 ·Status: COMPLETED ·Phase: PHASE2/PHASE3
-
Comparative Effects Of Dialysate Flow Rate And Membrane Packing On The Performance Of Dialyzers Used For Hemodialysis
NCT00636077 ·Status: COMPLETED ·Phase: NA
-
Dialysis Membranes and Hemodynamic Tolerance
NCT01898234 ·Status: COMPLETED ·Phase: NA
-
Functional Proteomics of Uremic Retention Solutes Associated With Immunosenescence, Inflammation and Impaired Adaptive Stress Response
NCT07265635 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Effect of a Medium Cut-Off Dialyzer - Medical Device on ESA Resistance in 110 Hemodialysis Patients (EXPAND)
NCT03874819 ·Status: UNKNOWN ·Phase: NA
-
Efficacy and Safety of Repeated-use Middle Cut Off Membrane Dialyzers in Hemodialysis Patients
NCT06950944 ·Status: COMPLETED ·Phase: NA
-
PERCI- Medium Cut Off (MCO)
NCT02084381 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Contact Phase Activation During Hemodialysis
NCT03090984 ·Status: COMPLETED ·Phase: NA
-
Comparison of Hemodialysis With Medium Cut-off Dialyzer (Theranova) and High Flux Dialyzer
NCT03211676 ·Status: COMPLETED ·Phase: NA
-
Improvement of Humoral Immune Response With Hemodialysis on BK-F Membrane: Correlation to Soluble CD40 Clearing
NCT01066559 ·Status: COMPLETED ·Phase: NA
-
Investigation on the Middle Size Molecule Elimination Characteristics of the FXCorDiax 100 in Relation to the FX 100 and the Polyflux 210 H Dialyser
NCT01578421 ·Status: COMPLETED ·Phase: NA
-
High Flux Hemodialysis Thrice Versus Once
NCT00714662 ·Status: UNKNOWN ·Phase: PHASE3
-
Carotid Intima-media Thickness as Cardiovascular Mortality Predictor in Peritoneal Dialysis Patients
NCT02938767 ·Status: COMPLETED
-
Investigation of the Effects of Medium Cut-off Dialyzers Versus High-Flux Dialyzers on Clinical and Laboratory Parameters of Prevalent Hemodialysis Patients
NCT05698420 ·Status: COMPLETED
-
Efficacy and Safety of Heparin-coated Surface-treated Polyacrylonitrile Membrane Hemofilter in Critical Ill CRRT Patients
NCT02355873 ·Status: COMPLETED ·Phase: PHASE4
-
First Evaluation of the Moda-Flx Hemodialysis System™ in Real World Clinical Settings
NCT06581393 ·Status: COMPLETED ·Phase: NA
-
Immunomodulatory Biomimetic Device to Treat Myocardial Stunning in End-stage Renal Disease Patients
NCT03539861 ·Status: TERMINATED ·Phase: NA