Single-Lead ECG Conduction Interval Algorithm
NCT07667465 · Status: RECRUITING · Type: OBSERVATIONAL · Enrollment: 50
Last updated 2026-07-21
Summary
The goal of this prospective, single-center and observational study is to develop and validate an optimization algorithm for single-lead ECG conduction intervals via the wearable ECG patches combined with synchronized heart sound data, and evaluate its agreement with the clinical gold standard (12-lead ECG) in adult patients. The main question: Does the optimized algorithm, based on ECG patches and synchronous heart sound recordings, improve the detection accuracy of PR interval, QRS duration, and QT interval compared with standard 12-lead ECG? It aims to answer: Participants (age ≥18 years, BMI \<35 kg/m², stable sinus rhythm with at least one abnormal conduction interval) will first undergo a 2-minute session of simultaneous ECG patches and digital stethoscope recordings, followed by standard 12-lead ECG, and then the repeated ECG patches and 2-minute heart sound recording session. Data will be used for algorithm training and validation. The primary endpoint is the accuracy of the optimized PR interval, QRS duration, and QT interval detection via the Vivalink ECG patches compared with the 12-lead ECG.
Conditions
- Conduction of Electrocardiogram
Sponsors & Collaborators
-
Second Affiliated Hospital, Zhejiang University, School of Medicine
collaborator OTHER -
Vivalink
lead INDUSTRY
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2026-07-16
- Primary Completion
- 2027-02-28
- Completion
- 2027-05-31
Countries
- China
Study Locations
More Related Trials
-
Analysis of the Efficacy and Stability of a Wearable ECG Monitor
NCT06546046 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Evolution of Intracardiac Electrograms Recorded by Left Bundle Branch Pacing Lead in Patients With ICD or CRT-D
NCT06745778 ·Status: RECRUITING
-
Performance and Accuracy of an AI Enhanced Smart Watch Single Lead ECG
NCT05450809 ·Status: COMPLETED
-
Validation of ECG Waveform and Arrhythmia Diagnosis Concordance for Pediatric Patients Using ECG Monitoring Patch
NCT05756309 ·Status: RECRUITING ·Phase: NA
-
Narrow QRS HF Patients Assessed by ECG Belt
NCT03367104 ·Status: COMPLETED
-
Correlating QLV Interval to Left Ventricular (LV) Lead Position in Patients Receiving Cardiac Resynchronization Therapy.
NCT02166762 ·Status: COMPLETED ·Phase: NA
-
Immediate Electrophysiological Effects of Different Atrial Pacing Sites on P-Wave Characteristics
NCT07603648 ·Status: RECRUITING ·Phase: NA
-
Evaluation of a Test Algorithm for Use to Analyze ECG Data Collected From a Test Device of a 24-hour Simulated Use Period
NCT07188129 ·Status: COMPLETED ·Phase: NA
-
Electrophysiological Optimization of Left Ventricular Lead Placement in CRT
NCT02346097 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Detection of Atrial Fibrillation by a Wearable Dynamic ECG Recorder
NCT04462653 ·Status: UNKNOWN ·Phase: NA
-
Safety and Effectiveness of Left Bundle Branch Area Pacing Versus Conventional Cardiac Resynchronization Therapy in Heart Failure
NCT07069738 ·Status: RECRUITING ·Phase: NA
-
The CT-verified Data Collection Study to Investigate the Correlation Between the Leadless Pacemaker Tip Location and Echo, ECG
NCT06910059 ·Status: ACTIVE_NOT_RECRUITING
-
LV Endocardial CRT for Patients With Intermediate QRS Width
NCT03573427 ·Status: WITHDRAWN
-
Evaluation of a Single-lead ECG Patch-based Telemetry System for In-hospital Monitoring
NCT07260721 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Smart Textile ECG Monitoring
NCT06870175 ·Status: RECRUITING ·Phase: NA
-
Comparison of 7-Day ECG Patches
NCT07564349 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Remote ECG Monitoring of TAVI Patients
NCT03810820 ·Status: UNKNOWN ·Phase: NA
-
Empiric Versus Imaging Guided Left Ventricular Lead Placement in Cardiac Resynchronization Therapy
NCT01323686 ·Status: COMPLETED ·Phase: NA
-
Electrocardiogram Clinical Validation Study
NCT03492554 ·Status: COMPLETED ·Phase: NA
-
Optimizing CRT With ECGI
NCT03492788 ·Status: TERMINATED ·Phase: NA
-
Intravascular ECG During Insertion of Peripheral Inserted Central-venous Catheters: Replacement for Chest X-ray?
NCT03197246 ·Status: COMPLETED ·Phase: NA
-
Telemetric Arrhythmia and Syncope Diagnosis - Evaluation of Arrhythmia Treatment Efficacy
NCT01265303 ·Status: UNKNOWN ·Phase: NA
-
The Application of a Portable Multichannel ECG System for the Patients Suspected to Have Possible CAD or ACS
NCT04787796 ·Status: UNKNOWN ·Phase: NA
-
Electrocardiogram (ECG) Guided Peripherally Inserted Central Catheter (PICC) Placement
NCT00742053 ·Status: TERMINATED ·Phase: NA
-
Optimizing Diagnostics Of Syncope Events Using Intelligent Telemetric Solutions.
NCT01265290 ·Status: UNKNOWN ·Phase: NA