Prospective Study on the Effectiveness and Safety of Bi-polar Pulse-field Tip-catheter Ablation for Atrial Fibrillation in China(POTENTIAL-AF)

NCT07627685 · Status: NOT_YET_RECRUITING · Type: OBSERVATIONAL · Enrollment: 30000

Last updated 2026-06-04

No results posted yet for this study

Summary

POTENTIAL-AF is a prospective, multicentre, observational registry study evaluating the real-world effectiveness and safety of bi-polar pulse-field tip-catheter ablation (PFA) for atrial fibrillation (AF) in China. The study will enrol 30,000 adult patients with symptomatic paroxysmal or persistent AF who have failed at least one antiarrhythmic drug (Class I or III) and are planned to undergo PFA using the Jinjiang LEAD-PFA system with PulsedFA catheter at participating centres across China.

All procedural decisions, including energy settings, ablation targets, and peri-procedural management, are made by the treating physician per routine clinical practice. The study prospectively collects baseline clinical characteristics, intraoperative ablation parameters, and follow-up outcomes at 3 months, 6 months, 12 months, and every 6 months thereafter, for up to 10 years.

The primary endpoint is all-cause mortality at 10 years. Secondary endpoints (observed over 5 years) include ischaemic stroke, haemorrhagic stroke, transient ischaemic attack (TIA), cardiovascular death, cardiovascular hospitalisation, systemic embolism, thromboembolic death, major bleeding, and clinically relevant non-major bleeding (CRNMB).

By capturing large-scale, standardised, long-term data across diverse Chinese centres, POTENTIAL-AF aims to describe real-world procedural practice patterns, identify predictors of clinical outcomes, and provide evidence to support the safe and effective application of the Jinjiang bi-polar tip PFA catheter in Chinese AF patients.

Conditions

Interventions

DEVICE

Bi-polar Pulse-field Ablation (PFA) - LEAD-PFA System with PulsedFA catheter

Participants undergo catheter ablation for atrial fibrillation using the Jinjiang bi-polar pulse-field ablation (PFA) system, comprising the LEAD-PFA generator and PulsedFA circular catheter (Jinjiang Electronic Medical Technology Co., Ltd., Sichuan, China). Catheter size (15 mm, 18 mm, or 25 mm) is selected by the operator based on individual anatomy. All patients undergo pulmonary vein isolation (PVI) as the mandatory ablation target. A minimum of 12 PFA applications are delivered per pulmonary vein (≥ 48 applications in total). Energy is delivered in bipolar mode at 2.0 kV, with each application comprising 5 pulse sequences over 2.5 seconds, non-synchronised to the QRS complex. Electrophysiological verification of entrance block (and exit block where applicable) is performed after PVI; additional applications are permitted if acute conduction recovery is observed.

Sponsors & Collaborators

  • Beijing Anzhen Hospital

    lead OTHER

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
Yes

Timeline & Regulatory

Start
2026-09-01
Primary Completion
2036-09-01
Completion
2036-09-30

Countries

  • China

Study Locations