Prospective Study on the Effectiveness and Safety of Bi-polar Pulse-field Tip-catheter Ablation for Atrial Fibrillation in China(POTENTIAL-AF)
NCT07627685 · Status: NOT_YET_RECRUITING · Type: OBSERVATIONAL · Enrollment: 30000
Last updated 2026-06-04
Summary
POTENTIAL-AF is a prospective, multicentre, observational registry study evaluating the real-world effectiveness and safety of bi-polar pulse-field tip-catheter ablation (PFA) for atrial fibrillation (AF) in China. The study will enrol 30,000 adult patients with symptomatic paroxysmal or persistent AF who have failed at least one antiarrhythmic drug (Class I or III) and are planned to undergo PFA using the Jinjiang LEAD-PFA system with PulsedFA catheter at participating centres across China.
All procedural decisions, including energy settings, ablation targets, and peri-procedural management, are made by the treating physician per routine clinical practice. The study prospectively collects baseline clinical characteristics, intraoperative ablation parameters, and follow-up outcomes at 3 months, 6 months, 12 months, and every 6 months thereafter, for up to 10 years.
The primary endpoint is all-cause mortality at 10 years. Secondary endpoints (observed over 5 years) include ischaemic stroke, haemorrhagic stroke, transient ischaemic attack (TIA), cardiovascular death, cardiovascular hospitalisation, systemic embolism, thromboembolic death, major bleeding, and clinically relevant non-major bleeding (CRNMB).
By capturing large-scale, standardised, long-term data across diverse Chinese centres, POTENTIAL-AF aims to describe real-world procedural practice patterns, identify predictors of clinical outcomes, and provide evidence to support the safe and effective application of the Jinjiang bi-polar tip PFA catheter in Chinese AF patients.
Conditions
Interventions
- DEVICE
-
Bi-polar Pulse-field Ablation (PFA) - LEAD-PFA System with PulsedFA catheter
Participants undergo catheter ablation for atrial fibrillation using the Jinjiang bi-polar pulse-field ablation (PFA) system, comprising the LEAD-PFA generator and PulsedFA circular catheter (Jinjiang Electronic Medical Technology Co., Ltd., Sichuan, China). Catheter size (15 mm, 18 mm, or 25 mm) is selected by the operator based on individual anatomy. All patients undergo pulmonary vein isolation (PVI) as the mandatory ablation target. A minimum of 12 PFA applications are delivered per pulmonary vein (≥ 48 applications in total). Energy is delivered in bipolar mode at 2.0 kV, with each application comprising 5 pulse sequences over 2.5 seconds, non-synchronised to the QRS complex. Electrophysiological verification of entrance block (and exit block where applicable) is performed after PVI; additional applications are permitted if acute conduction recovery is observed.
Sponsors & Collaborators
-
Beijing Anzhen Hospital
lead OTHER
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2026-09-01
- Primary Completion
- 2036-09-01
- Completion
- 2036-09-30
Countries
- China
Study Locations
More Related Trials
-
Pulsed Field Ablation Versus Radiofrequency Ablation for Persistent Atrial Fibrillation
NCT06791629 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Catheter Ablation and Surgical Ablation of Persistent Atrial Fibrillation With Severe Atrial Fibrosis
NCT05153486 ·Status: UNKNOWN ·Phase: NA
-
Comparison of Different Ablation Surgeries on Left Atrial Reverse Remodeling in Patients With Atrial Fibrillation
NCT06307860 ·Status: RECRUITING
-
Pulsed Field Ablation Versus Radiofrequency Ablation: Effects of Pulmonary Vein Isolation Combined With Left Atrial Posterior Wall Isolation on Postoperative Gastric Motility in Patients With Persistent Atrial Fibrillation
NCT07612241 ·Status: NOT_YET_RECRUITING
-
Optimal Ablation Strategies for Persistent AF With HF
NCT07153718 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Comparison Between Upgraded '2C3L' vs. PVI Approach for Catheter Ablation of Persistent Atrial Fibrillation
NCT04497376 ·Status: COMPLETED ·Phase: NA
-
Clinical Efficacy of Left Bundle Branch Area Pacing for Patients With Permanent Atrial Fibrillation and Heart Failure
NCT05549544 ·Status: RECRUITING ·Phase: NA
-
Left Atrium Substrate Based Ablation Plus Circumferential Pulmonary Vein Isolation to Treat Chronic Atrial Fibrillation
NCT01716143 ·Status: UNKNOWN ·Phase: NA
-
Comparative Efficacy and Safety of Extensive Electro-Anatomical Guided Pulsed Field Ablation Versus Radiofrequency Ablation in Persistent Atrial Fibrillation
NCT06745167 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
A Multicenter Study of Pulsed Field Ablation for Paroxysmal Supraventricular Tachycardia
NCT05820035 ·Status: COMPLETED ·Phase: NA
-
Unipolar Voltage Mapping for Personalized Atrial Fibrillation Ablation
NCT07630857 ·Status: RECRUITING ·Phase: NA
-
PFA-based Bi-atrial Maze-like Catheter Ablation for PeAF
NCT06952023 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Node and Atrial Fibrillation Ablation for Persistent Atrial Fibrillation
NCT01057485 ·Status: UNKNOWN ·Phase: NA
-
A Study on the Therapeutic Value of Additional Left Atrial Posterior Wall Isolation Guided by Voltage Mapping in Persistent Atrial Fibrillation.
NCT07590661 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Wide Area Circumferential Ablation With Contact Force Versus Cryoballoon Ablation
NCT03564925 ·Status: UNKNOWN ·Phase: NA
-
Prospective Cohort Study of the Risk of Recurrent Atrial Fibrillation After Radiofrequency Ablation
NCT05638841 ·Status: RECRUITING
-
Study Comparing Pulmonary Vein Isolation With the Cryoballoon and Radiofrequency Energy(Contact Force) in the Treatment of Persistent Atrial Fibrillation (AF) (Cryo Vs CF in PerAF)
NCT03053570 ·Status: UNKNOWN ·Phase: NA
-
Safety-and-effectiveness Clinical Evaluation of Nanosecond-pulse Ablation for Atrial Fibrillation
NCT06039722 ·Status: COMPLETED ·Phase: NA
-
A Randomized Controlled Study of Ablation Pursuing Atrial Fibrillation Termination as a Procedural Endpoint in Patients With Persistent Atrial Fibrillation
NCT05921734 ·Status: COMPLETED ·Phase: NA
-
SAfety and eFfectiveness of cathetER Ablation for Atrial Fibrillation With Intracranial Hemorrhage (SAFER-AF)
NCT07316270 ·Status: RECRUITING ·Phase: NA
-
Safety And FEasibility of a Simplified Deep Sedation Protocol for Pulsed-Field Ablation
NCT07633548 ·Status: ENROLLING_BY_INVITATION
-
Radiofrequency Ablation for Polymorphic Ventricular Tachycardia With Heart Failure (RFCA for PMVT-HF)
NCT07130175 ·Status: COMPLETED ·Phase: NA
-
Atrial Fibrillation with Heart Failure with Preserved Ejection Fraction: Treatment Strategies-Catheter Ablation Vs. Anti-Atrial Arrhythmia Drugs
NCT06740539 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Study on the Ablation of Persistent Atrial Fibrillation Using Pulsed Electric Fields Under Different Surgical Procedures
NCT06671197 ·Status: NOT_YET_RECRUITING
-
Atrial Remodeling After PFA Substrate Modification for Persistent AF (PeAF)
NCT07675395 ·Status: NOT_YET_RECRUITING ·Phase: NA