Precision of Patient Specific 3D Printed Occlusal Stent, Surgical Guide, and Patient Specific Titanium Plates in Management of Mandibular Fracture (Case Series)
NCT07499726 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 6
Last updated 2026-04-03
Summary
This study evaluates the accuracy of preoperative fully computerized occlusal stents, surgical guide, and patient-specific titanium plates in guided mandibular fracture reduction and fixation. The research question is: Does the use of patient-specific three-dimensional (3D) printed occlusal stents, surgical guides, and titanium plates accurately reduce mandibular fractures regarding guided fracture reduction, fixation, and occlusion? Mandibular fractures are among the most common maxillofacial fractures observed in the emergency room. The evaluation, diagnosis, and management of these fractures remain challenging despite improved imaging technology and fixation techniques. Depending on the type and location of the fractures, various open and closed surgical reduction techniques can be utilized. There are several critical and inherent limitations to the current standard approach of mandibular fracture reduction and fixation.
The anatomical term "body fractures" is used in the present study. It refers to the tooth-bearing area of the mandible including symphyseal, parasymphyseal, and body fractures. Anatomically, the mandible consists of a curved horizontal portion (the body) with the alveolar process on top, and two perpendicular portions (the rami), which unite with the ends of the body nearly at right angles.
Conventionally, surgical plates are mass-produced with universal configurations that must be manually bent to match individual bone anatomy. The plate bending procedure can be time-consuming and technically demanding, especially for inexperienced surgeons. In complex cases, surgical plates may need to be bent repeatedly, which induces internal stress concentration. The stressed plates may suffer from fatigue under in vivo masticatory loading, resulting in complications including plate fracture, corrosion, screw loosening, and bone resorption.
Three-dimensional (3D) printing involves additive manufacturing techniques used to build structures layer by layer. This technology has been adapted to a wide range of surgical applications. It has been used to print patient-specific anatomic models, implants, prosthetics, external fixators, splints, surgical instrumentation, and surgical cutting guides. The utility of this technology in surgery explains its rapid adoption.
There are no comparators in this study because it is a case series. Objectives: This study aims to evaluate the accuracy of preoperative fully computerized occlusal stents, surgical guides, and patient-specific titanium plates in guided mandibular fracture reduction and fixation.
Primary Objectives:
* To achieve anatomical reduction with accurate post-operative occlusion
* To reduce intra-operative time with subsequent reduction in post-operative pain and edema Hypothesis: We hypothesize that preoperative fully computerized occlusal stents, surgical guides, and patient-specific titanium plates are an accurate method for mandibular fracture reduction and fixation.
Trial Design: This is a prospective case series study conducted on adult patients with mandibular fractures.
PIO:
* Population: Patients with mandibular fracture requiring open reduction internal fixation (ORIF)
* Intervention: Preoperative fully computerized occlusal stents, surgical guides, and patient-specific titanium plates
* Outcome: Accuracy of reduction and occlusion
Conditions
- Mandibular Fractures
Interventions
- PROCEDURE
-
Patient-Specific 3D Printed Occlusal Stent, Surgical Guide, and Titanium Plates
Patients underwent preoperative virtual surgical planning using Mimics software. Patient-specific three-dimensional (3D) printed occlusal stents, surgical guides, and titanium plates (2.0 mm thickness, Grade 4 titanium) were fabricated. Surgical procedure included intraoral or extraoral approach as indicated, fracture reduction using custom guides, fixation with patient-specific plates, and standard postoperative care including antibiotics and soft diet for 4-6 weeks. Postoperative computed tomography (CT) scan was obtained at 4 weeks for accuracy assessment via superimposition analysis.
Sponsors & Collaborators
-
Cairo University
lead OTHER
Eligibility
- Min Age
- 18 Years
- Max Age
- 65 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2024-07-06
- Primary Completion
- 2025-07-09
- Completion
- 2025-07-10
Countries
- Egypt
Study Locations
More Related Trials
-
A Comparative Study Between Three Different Plating Techniques in Management of Mandibular Parasymphyseal Fractures.
NCT06323122 ·Status: COMPLETED
-
Radiographic Assessment of Three Dimensional Mandibular Position Using Splint-less Patient Specific Implant
NCT06160661 ·Status: RECRUITING ·Phase: NA
-
CAD/CAM Angle Fracture Reduction/Plate Guide and Customized 3D Grid Plate Versus Champy's Technique
NCT06392204 ·Status: COMPLETED ·Phase: NA
-
3D Interlocking Miniplates in Fixation of Mandibular Fractures in the Mental Foramen Region: A Split-mouth Study
NCT06939010 ·Status: COMPLETED ·Phase: PHASE4
-
Computer Guided Simultaneous Implant Placement With Tri-cortical Ridge Augmentation Using Chin Cortical Bone Struts in Anterior Atrophic Maxilla: A Case Series
NCT05731063 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of Modified Omega Plate in the Management of Mandibular Fractures Compared With Conventional Fixation
NCT07206134 ·Status: COMPLETED ·Phase: NA
-
Custom-Made 3D PEEK for Fixation of Mandibular Angle Fractures.
NCT07156812 ·Status: COMPLETED ·Phase: PHASE4
-
Evaluation of a Combined Ridge Expansion Technique With Simultaneous Dental Implant Placement
NCT05685576 ·Status: COMPLETED ·Phase: NA
-
Computer Guided Buccal Cortical Plate Separation for Removal of Calcified Benign Odontogenic Tumors Affecting Mandibular Angle Region
NCT05329974 ·Status: COMPLETED ·Phase: NA
-
Comparison Between Two Techniques to Reposition the Maxilla After le Fort 1
NCT06132906 ·Status: COMPLETED ·Phase: NA
-
Computer Guided Screw Holes Locating Guide and Custom-made Plates
NCT05647460 ·Status: UNKNOWN ·Phase: NA
-
Marginal Bone Changes in Fixed All-on-Four Mandibular Prosthesis Using OT Bridge Attachment System
NCT05924386 ·Status: RECRUITING ·Phase: NA
-
Posterior Mandibular Ridge Augmentation Using Mineralized Plasmatic Matrix Versus Autogenous Bone Graft
NCT02998632 ·Status: UNKNOWN ·Phase: NA
-
Patient Centered Outcomes and Marginal Bone Changes in CAD/CAM Metallic and (PEEK) Partial Denture Frameworks
NCT05622448 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Z-shaped Bone Plates in Management of Mandibular Fractures
NCT07184762 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Evaluation of the Accuracy of Patient Specific Implant in Fixation of Mandibular Sagittal Split Osteotomy
NCT07222904 ·Status: COMPLETED ·Phase: NA
-
Splinted and Unsplinted OT Bridge Systems in Screw Retained Implant Restoration
NCT05031156 ·Status: UNKNOWN ·Phase: NA
-
Stryker's Surgeon iD Mandible Reconstruction Plates: A Retrospective Post Market Follow Up
NCT07221916 ·Status: COMPLETED
-
Clinical and Radiographic Evaluation of Three Different Modalities for Management of Distal Extension Atrophied Mandibular Ridge: A One Year Prospective Study
NCT05978115 ·Status: UNKNOWN ·Phase: NA
-
Mandibular Reconstruction Bone Plate
NCT06099431 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Evaluation of Autogenous Demineralized Dentin Graft for Ridge Preservation With and Without Injectable Platelet Rich Fibrin
NCT05437172 ·Status: COMPLETED ·Phase: NA
-
Implant Placement in Mandibular Molar Xenograft Versus PRF
NCT03177356 ·Status: UNKNOWN ·Phase: NA
-
Skeletal Stability of Le Fort I Osteotomy Using Patient-specific Osteosynthesis Compared to Mini-plate Fixation for Patients With Dentofacial Disharmony
NCT05340036 ·Status: UNKNOWN ·Phase: NA
-
Prosthetic Management of All on Four Versus All on Six to Rehabilitate Completely Edentulous Maxillary Ridge Opposed by Natural Teeth
NCT06114069 ·Status: COMPLETED ·Phase: NA
-
The Influence of 3D Surgical Template on the Contour of Bone Augmentation, in Patient With Labial Alveolar Ridge Defect and Simultaneous Implantation
NCT06312384 ·Status: ACTIVE_NOT_RECRUITING ·Phase: PHASE3