Influence of Zirconia Abutments on Peri-Implant Tissues in Single-Tooth Restorations
NCT07456163 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 71
Last updated 2026-03-17
Summary
Objectives:
To compare the influence of pre-fabricated titanium abutments and customized milled zirconia abutments on implant biocompatibility and the peri-implant region, as well as on radiographic bone loss and oral health-related quality of life.
Detailed Methodology:
This study is a randomized controlled clinical trial designed to evaluate the biological and clinical behavior of standardized titanium abutments compared with customized anatomical zirconia abutments in single implant-supported posterior restorations. The present investigation represents the prosthetic phase of a previously conducted randomized clinical trial that evaluated dimensional changes following different alveolar preservation protocols in posterior regions (CAAE: 59208422.8.0000.5418). In the previous phase, participants underwent tooth extraction and alveolar preservation procedures, followed by implant placement with Morse Taper (CM) implants (Biomorse XP, Bionnovation Biomedical) after a six-month healing period. After implant osseointegration, participants eligible for prosthetic rehabilitation will be randomly allocated to one of two parallel groups using a computer-generated randomization sequence (Sealedenvelope.com). The allocation ratio will be 1:1. Sample size calculation was performed using GPower software to ensure adequate statistical power. The intervention consists of prosthetic rehabilitation with either standardized titanium abutments (TiB group) or customized anatomical zirconia abutments (ZiT group), both supporting single zirconia crowns in posterior regions. All prosthetic and laboratory procedures will follow standardized clinical protocols. Clinical and laboratory assessments will be conducted at prosthesis delivery (baseline) and at 1-, 3-, 6-, and 12-month follow-up visits. Data collection will include peri-implant crevicular fluid (PICF) and biofilm sampling for biomolecular analysis, comprehensive periodontal clinical parameters, measurement of keratinized mucosa thickness, standardized periapical radiographs for marginal bone level assessment, and intraoral digital scanning for volumetric and soft tissue analysis. The primary objective is to compare peri-implant tissue stability and biological response between titanium and zirconia abutments. Secondary outcomes include clinical parameters, marginal bone level changes, and soft tissue dimensional stability over a 12-month follow-up period. This study aims to contribute to the understanding of how abutment material and design may influence peri-implant health and long-term tissue stability in posterior implant-supported restorations.
Conditions
- Peri-Implant Health
- Implant Complication
- Prosthesis and Implants
Interventions
- DEVICE
-
Pre-fabricated standardized titanium abutments
Participants receive prosthetic rehabilitation with manufacturer-provided pre-fabricated standardized titanium abutments connected to previously osseointegrated Morse Taper implants. After abutment placement, single zirconia crowns are installed following standardized digital prosthetic procedures.
- DEVICE
-
Customized anatomical zirconia abutments
Participants receive prosthetic rehabilitation with CAD/CAM-fabricated customized anatomical zirconia abutments connected to previously osseointegrated Morse Taper implants. After abutment placement, single zirconia crowns are installed following standardized digital prosthetic procedures.
Sponsors & Collaborators
-
University of Campinas, Brazil
lead OTHER
Principal Investigators
-
Renato Casarin, Associate Professor · University of Campinas, Brazil
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 70 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2025-04-30
- Primary Completion
- 2026-05-30
- Completion
- 2027-12-01
Countries
- Brazil
Study Locations
More Related Trials
-
A Comparison Between Protemp and Flowable Light Cure Composite Material for Creating Optimal Gingival Emergence Profile Around Implant
NCT07196293 ·Status: COMPLETED ·Phase: NA
-
Abutment Macro Design and Peri-implant Tissues
NCT02546713 ·Status: COMPLETED ·Phase: NA
-
Comparing Cobalt-Chromium Versus PEEK Secondary Telescopic Crowns on Implant Retained Mandibular Overdenture.
NCT06637930 ·Status: COMPLETED ·Phase: NA
-
Prosthetic Outcomes and Clinical Performance of Implant Supported Zirconia Crowns
NCT06417632 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Natural Dentition, Prosthesis and Antagonist Wear 3D Analysis
NCT05637619 ·Status: RECRUITING
-
Aesthetic Outcomes of Single Tooth Implant Using Metal Ceramic Restorations With Either Zirconia or Titanium Abutments
NCT02315794 ·Status: COMPLETED ·Phase: PHASE2
-
Implant Retained Rehabilitation With Surgical and Prosthetic Digital Workflow
NCT04066309 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Bacterial Microleakage and Bone Loss in Internal Connection Dental Implants Based on the Type of Abutment Used in Zirconia Partial Fixed Prosthesis: in Vivo Study
NCT06156111 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Dimensional Changes of Peri-implant Tissue in Immediate Implants With Individualized Healing Abutments
NCT06455436 ·Status: RECRUITING ·Phase: NA
-
Evaluation of Occlusal Adjustment Material Removal on Monolithic Zirconia Blocks: An In Vitro Study
NCT07280130 ·Status: NOT_YET_RECRUITING
-
Single-retainer Lithium Di-silicate Versus Zirconia Resin Bonded Bridge for Replacement of an Anterior Missing Tooth.
NCT05861921 ·Status: COMPLETED ·Phase: NA
-
Effect of Abutment Configuration on Peri-implant Soft and Hard Tissue in the Esthetic Zone - Randomized Clinical Trial
NCT06407271 ·Status: RECRUITING ·Phase: NA
-
Zirconia Based Fixed Dental Prostheses
NCT02220764 ·Status: COMPLETED ·Phase: NA
-
Removable Partial Denture Abutments Restored With Monolithic Zirconia Crowns
NCT03283709 ·Status: TERMINATED ·Phase: NA
-
Properties and Clinical Performance of Zirconia-based Dental Ceramics
NCT00737308 ·Status: COMPLETED ·Phase: NA
-
Intraoral vs Extraoral Cementation of Zirconia Bridges on Ti-Bases: Microstrain Evaluation
NCT07448701 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Comparative Clinical Study of Conventional vs Customized Healing Abutments in Dental Implantology
NCT07031232 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Evaluation of the Abutment Type Following Oral Implants in Terms of the Surrounding Bone Height
NCT05350293 ·Status: COMPLETED ·Phase: NA
-
Study of the Integration Success of an Implant System With a Novel Abutment Attachment Design in Immediate Loading Cases
NCT01529866 ·Status: COMPLETED ·Phase: NA
-
Three Years Radiographic Evaluation of Different Implant Retained Complete Over Denture Attachments (In Vivo Study)
NCT06962358 ·Status: COMPLETED
-
Bio-HPP vs Cast Co-cr as Implant Framework
NCT05861388 ·Status: COMPLETED ·Phase: NA
-
Zirconia Bars for Mandibular Implant Overdentures
NCT06471881 ·Status: COMPLETED ·Phase: NA
-
Randomized Controlled Clinical Trial of CAD/CAM and Conventionally Fabricated Singl Implant Abutments.
NCT01229995 ·Status: UNKNOWN ·Phase: NA
-
Patient Satisfaction, Peri-implant Parameters and Crestal Bone Evaluation of PEEK (Polyetheretherketone) Abutments Versus Zirconium Abutments Restored With PEEK Based Superstructure
NCT03714074 ·Status: UNKNOWN ·Phase: NA
-
Comparison Between Injection Molded PEEK Framework and Cobalt Chromium Framework in Removable Partial Denture Regarding Retention
NCT03777280 ·Status: UNKNOWN ·Phase: NA