Assessment of the EndoR System in ESD for Colorectal Lesions
NCT07405203 · Status: ACTIVE_NOT_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 6
Last updated 2026-02-12
Summary
Gastrointestinal (GI) cancers are common and significant causes of cancer death worldwide. GI cancers grow from the mucosal layer. If pre-malignant and early cancers are removed en bloc at an early stage before they spread to lymph nodes, survival rates can be improved.
Endoscopic mucosal resection (EMR) and endoscopic submucosal dissection (ESD) were developed as minimally invasive, organ-sparing methods for removing pre-malignant and early GI cancers. While EMR is suitable for smaller lesions, ESD is typically required for larger lesions. ESD offers the advantage of a higher rate of complete, single-piece resection, which is associated with a lower risk of local recurrence compared to EMR. However, ESD is a technically complex procedure with a higher risk of complications, such as perforation and bleeding.
Conventional ESD is performed using a flexible endoscope with a single instrument channel to access the GI tract. This setup presents several challenges, including difficulty in maintaining the endoscope in a stable position, limited ability to provide effective tissue traction, and frequent intraprocedural bleeding. As a result, ESD demands a high level of technical skills from surgeons.
The EndoR Surgical System was developed to address these challenges, aiming to allow surgeons to operate two surgical instruments with enhanced dexterity and a broader range of motions. Both pre-clinical ex-vivo studies and in-vivo studies were conducted in the development of this surgical system.
Six pre-clinical ex-vivo studies were conducted in porcine stomach between 2015 and 2023 and eleven pre-clinical in-vivo studies were conducted in live porcine models with the lesion sites at stomach, rectum and left colon between 2016 and 2024. These pre-clinical studies were conducted in LASEC-PWH, MISSC-PWH and Hybrid Operating Room of Multi-Scale Medical Robotics Center (MRC) accordingly.
Based on data from the ex-vivo and in-vivo experiments, two key conclusions can be drawn:
i) After several training sessions, the operator's performance became more consistent and efficient.
ii) The dissection rate increased as the dissection area grew-a phenomenon not observed in conventional procedures using a single endoscope and dissection tool.
From the results demonstrated from the pre-clinical studies, the EndoR Surgical System allows for greater dexterity and precision in manipulating instruments, which is particularly advantageous for larger lesions. This precision can lead to more effective dissection and reduced damage to surrounding tissues. This may also reduce the risk of complications associated with ESD. By minimizing trauma to adjacent structures, the likelihood of adverse events, such as bleeding or perforation, may be significantly lowered. Patients may experience faster recovery times, contributing to improved patients' satisfaction and outcomes. As the risk of complications decreases, endoscopic procedures like ESD could become accessible to a broader patient population.
While performing ESD is generally considered safe, it still remains a technically demanding procedure with the assistance of the surgical robotic system. The use of surgical robots introduces the risk of equipment malfunctions, which can lead to complications during the procedure. Additionally, any technical issues may result in delays, potentially compromising patient safety.
The attending physicians will monitor and examine the subjects as necessary and appropriate and work carefully to ensure their safety. In the event of an adverse reaction, countermeasures will be taken as appropriate, and focus will be placed on ensuring the safety of the subjects while the cause of the reaction is investigated.
The objective of this study is to assess the safety and performance of the EndoR Surgical System for the treatment of patients with colorectal malignant lesions. Technical success, clinical success and any adverse events shall be recorded.
Conditions
- Colorectal Lesions
Interventions
- DEVICE
-
EndoR Surgical System
The EndoR Surgical System is a master-slave robotic platform designed for endoscopic surgery, featuring flexible dual arms and cognitive control system.
Sponsors & Collaborators
-
Chinese University of Hong Kong
lead OTHER
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Max Age
- 85 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2026-01-01
- Primary Completion
- 2027-12-31
- Completion
- 2028-06-30
Countries
- Hong Kong
Study Locations
More Related Trials
-
Endoscopic Submucosal Dissection Versus Laparoscopic Resection for Early Colorectal Neoplasms
NCT01112046 ·Status: UNKNOWN ·Phase: PHASE3
-
Magnetic Guided Counetrtraction During Endoscopic Submucosal Dissection
NCT06962293 ·Status: RECRUITING ·Phase: NA
-
Efficacy and Safety of Robot-assisted Endoscopic Submucosal Dissection for Colorectal Neoplasm
NCT06973083 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Endoscopic Submucosal Dissection for Gastrointestinal Neoplasms
NCT01378507 ·Status: UNKNOWN ·Phase: NA
-
Full Thickness Resection or Endoscopic Submucosal Dissection for Difficult Colorectal Lesions.
NCT05502276 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Endoscopic Submucosal Dissection (ESD) Efficacy
NCT01879904 ·Status: COMPLETED ·Phase: NA
-
Follow-up Protocol of Colorectal Endoscopic Mucosal Resection Scars
NCT04239365 ·Status: COMPLETED ·Phase: NA
-
Modified Double Snare Assisted EMR (mDS-EMR) VS ESD for Rectal Neuroendocrine Tumors Smaller Than 1cm
NCT07373015 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Endoscopic Submucosal Dissection (ESD) and Endoscopic Mucosal Band Ligation (EMBL) for Early Cancer
NCT02952794 ·Status: UNKNOWN
-
Diagnostic Value of Endocytoscopy for Colorectal Lesions
NCT06324097 ·Status: COMPLETED
-
A Novel Robotic System for Single Port and Natural Orifice Transluminal Endoscopic Surgery
NCT03010813 ·Status: COMPLETED ·Phase: NA
-
Endoscopic Resection for Small Rectal Neuroendocrine Tumors
NCT05429216 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Real-time AI-assisted Endocyroscopy for the Diagnosis of Colorectal Lesions
NCT06791395 ·Status: COMPLETED
-
An Endoscopic Barbed-clips Suturing for Colorectal ESD
NCT05045911 ·Status: UNKNOWN ·Phase: NA
-
ESD for Colorectal LSL Using a Selective Strategy - a Prospective Cohort Study
NCT04008407 ·Status: RECRUITING ·Phase: NA
-
Endoscopic Ultrasound Guided Colorectal ESD and Traditional Colorectal ESD Surgery
NCT06076382 ·Status: RECRUITING ·Phase: NA
-
Clinical Study on the Accuracy of Real-time AI-assisted Endocytoscopy in the Diagnosis of Colorectal Diminutive Polyps
NCT06791408 ·Status: RECRUITING
-
Transanal Tube Drainage in Endoscopic Submucosal Dissection of the Colorectal Tumor
NCT02973490 ·Status: UNKNOWN ·Phase: NA
-
Validation of AI-ENDO System in Endoscopic Submucosal Dissection
NCT07392268 ·Status: RECRUITING ·Phase: NA
-
Prospective Study of Using Novel Bipolar Scissors in Colorectal Endoscopic Submucosal Dissection
NCT06715332 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Endoscopic Treatment of Rectal Neuroendocrine Tumor(NET) Less Than 10mm
NCT03982264 ·Status: UNKNOWN ·Phase: NA
-
Endoscopic Mucosal Resection Versus Endoscopic Submucosal Dissection for Colorectal Laterally Spreading Lesions.
NCT04593407 ·Status: RECRUITING ·Phase: NA
-
Brief Title : Optimized Endoscopic Submucosal Dissection With Snaring for Colorectal Neoplasm
NCT01944540 ·Status: UNKNOWN ·Phase: NA
-
Outcomes of Perforation After Colorectal Endoscopic Submucosal Dissection
NCT05728710 ·Status: UNKNOWN
-
French Colorectal ESD Cohort in Experts Centers
NCT04592003 ·Status: RECRUITING