Optimizing HFrEF Patients Using BaroStim and CardioMems
NCT07399587 · Status: RECRUITING · Phase: PHASE2/PHASE3 · Type: INTERVENTIONAL · Enrollment: 15
Last updated 2026-02-10
Summary
The goal of this study is to utilize CardioMems (measurement of pulmonary artery diastolic pressure) to assess BaroStim. At the time of CardioMems insertion, patients will be screened for candidacy to receive a BaroStim device. Patients will be followed for 3 months after the CardioMems insertion before undergoing insertion of a Barostim. Patients who have undergone a CardioMems, will be eligible for enrollment after 3 months of medication management and optimization. Patients will be followed for 1 year after insertion of Barostim.
Conditions
- Heart Failure NYHA Class III
Interventions
- DEVICE
-
BaroStim
BaroStim NEO or BaroStim NEO2 will be used in this study. The device consists of a Carotid sinus lead 2 mm in thickness and an implantable pulse generator. The study intervention is monitoring of CardioMems reading while titrating the BaroStim device.
Sponsors & Collaborators
-
Northwell Health
lead OTHER
Principal Investigators
-
John Kassotis, MD · Northwell Health
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2025-01-17
- Primary Completion
- 2028-12-31
- Completion
- 2029-12-31
Countries
- United States
Study Locations
More Related Trials
-
Real-World Experience - Barostim™ Advancing the Level of Clinical Evidence (REBALANCE Registry)
NCT04502316 ·Status: ACTIVE_NOT_RECRUITING
-
CardioMEMS HF System Real-World Evidence Post-Approval Study
NCT06306573 ·Status: ENROLLING_BY_INVITATION
-
Evaluation of a Diagnostic Feature in a Cardiac Resynchronization Therapy (CRT) Device
NCT00957541 ·Status: COMPLETED ·Phase: PHASE2
-
Investigation to Optimize Hemodynamic Management of Left Ventricular Assist Devices Using the CardioMEMS™
NCT03247829 ·Status: COMPLETED
-
Restoration of Chronotropic Competence in Heart Failure Patients With Normal Ejection Fraction
NCT00670111 ·Status: TERMINATED ·Phase: NA
-
Validation of CardioMEMS HF System Cardiac Output Algorithm IDE
NCT05428384 ·Status: COMPLETED
-
Interventricular Delay of Lumax HF-T for Heart Failure
NCT00508391 ·Status: COMPLETED ·Phase: PHASE2
-
Heart Failure Optimization Study
NCT03016754 ·Status: COMPLETED
-
Multiple Cardiac Sensors for the Management of Heart Failure
NCT03237858 ·Status: COMPLETED ·Phase: NA
-
Cardiac Resynchronization Therapy (CRT) Based Heart Failure Monitoring Study
NCT00632372 ·Status: COMPLETED
-
PROSPECT: Predictors of Response to Cardiac Re-Synchronization Therapy
NCT00253357 ·Status: COMPLETED
-
Heart Failure Management for Patient With CIED Remotely Monitored
NCT07247032 ·Status: RECRUITING ·Phase: NA
-
Registry of Patients With CardioMEMS
NCT02729922 ·Status: COMPLETED
-
RESpiration deTection From Implanted Cardiac Devices in Subjects With Heart Failure (REST-HF)
NCT03087084 ·Status: UNKNOWN ·Phase: NA
-
PREVENT-HF: Prevention of Heart Failure Events With Impedance Cardiography Testing
NCT00409916 ·Status: UNKNOWN ·Phase: PHASE4
-
A Study Testing a New Heart Scan Method to Improve Pacemaker Treatment for Heart Failure
NCT07084467 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
An Early Feasibility Study Evaluation of an Implant Free Interatrial Shunt to Improve Heart Failure
NCT06859970 ·Status: RECRUITING ·Phase: NA
-
REsynchronization reVErses Remodeling in Systolic Left vEntricular Dysfunction (REVERSE)
NCT00271154 ·Status: COMPLETED ·Phase: NA
-
REmodeling the Left Ventricle With Atrial Modulated Pacing
NCT03210402 ·Status: COMPLETED ·Phase: NA
-
CardioMEMS HF System OUS Post Market Study
NCT02954341 ·Status: COMPLETED
-
CardioMEMS HF System Post Approval Study
NCT02279888 ·Status: COMPLETED
-
TARGET-LOAD Pilot Study Comparing Hemodynamics-guided LVAD Unloading Vs. Standard of Care
NCT04977310 ·Status: WITHDRAWN ·Phase: NA
-
INvestigation on Routine Follow-up in CONgestive HearT FAilure Patients With Remotely Monitored Implanted Cardioverter Defibrillators (ICD) SysTems
NCT01200381 ·Status: COMPLETED ·Phase: NA
-
Diagnostic Device Risk Management of Atrial Fibrillation and Heart Failure
NCT01486316 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Left Ventricular AutoThreshold
NCT00812201 ·Status: COMPLETED