Clinical Validation of Non-Contact Vital Signs
NCT07362641 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 112
Last updated 2026-01-23
Summary
Vital signs are critically important to modern emergency medical care. These metrics (heart rate (HR), respiratory rate (RR), blood pressure, temperature, and pulse oximetry) have been shown to predict a patient's morbidity, mortality, need for ICU-level admission, and suitability for discharge. As such, vital signs are used at multiple points of emergency department (ED) care, from triage through treatment through disposition.
Unfortunately, the acquisition of vital signs can be a time-intensive process. Time-and-motion studies have shown the measurement and recording of vital signs may take over five minutes per patient and longer with interruptions.5 Increased crowding, lack of available staff, and length-of-stay have all been shown to delay or decrease the frequency of vital sign measurements. Some studies have shown a majority of both children and adults may be missing vital signs during their ED stays. Other studies have shown repeat vital signs to be taken less frequently every two hours. With increasing boarding and crowding in ED settings, the frequency of vital sign acquisition may be significantly worse than this reported data.
Many emergency departments have sought to improve vital sign acquisition through various quality improvement initiatives. Some researchers have also evaluated alternative means of vital sign acquisition. Telemedical providers, for instance, have evaluated the accuracy of patients' self-reported vital signs. Device studies have also looked at non-contact vital signs via radar and thermal imaging. More recently, studies have evaluated the feasibility of acquiring vital signs using cameras.
These studies of camera-acquired vital signs have shown promise, though they are limited by small sample sizes. Here, we present the clinical validation of camera-acquired vital signs obtained from commercially available products over a larger sample size.
Conditions
- Vital Sign Evaluation
Interventions
- DEVICE
-
SmartSpectra Vital Signs Monitor measurement
The objective of the study was to evaluate the safety and effectiveness of the SmartSpectra Vital Signs Monitor version 1.0.0 vis-a-vis standard-of-care, FDA-cleared Philips Intellivue MX450 patient monitor device (FDA Clearance K130849)("MX450"). The MX450 measures end-tidal CO2 ("EtCO2") and three-lead electrocardiogram ("ECG") waveforms.
Sponsors & Collaborators
-
Presage Technologies, Inc.
lead INDUSTRY
Eligibility
- Min Age
- 18 Years
- Max Age
- 75 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2025-03-28
- Primary Completion
- 2025-04-21
- Completion
- 2025-04-21
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Non-invasive Technology for Early Signal Detection of Hypoxemia With ORI During Intubation
NCT03600181 ·Status: COMPLETED
-
Comparison of Nasal and Forehead Oximetry in Critically Ill Patients at Risk for Decreased Peripheral Perfusion
NCT02382133 ·Status: COMPLETED ·Phase: NA
-
Camera-based Measurement of Respiratory Rates
NCT02837341 ·Status: COMPLETED ·Phase: NA
-
Respiratory Rate Validation Study - RS001.2 Respiree Cardio-Respiratory Monitor
NCT05210712 ·Status: COMPLETED
-
N600X Low Saturation Accuracy Validation
NCT05532670 ·Status: COMPLETED
-
Desaturation Validation of INVSENSOR00028
NCT03704636 ·Status: COMPLETED ·Phase: NA
-
VRES Study in Two Phases to Monitor Cardiac Surgical Patients Following Discharge From ICU
NCT02427828 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Continuous SpO2 Measurement in Adults
NCT01183338 ·Status: WITHDRAWN
-
Accuracy and Precision of Different Devices for the Monitoring of Pulsed Oxygen Saturation
NCT02832817 ·Status: UNKNOWN
-
Automated Respiration Rate to Improve Accuracy of the Electronic Cardiac Arrest Risk Triage Score (eCART) Algorithm
NCT02399930 ·Status: COMPLETED
-
Technical Feasibility Study of a Novel Wearable Capnograph (MARIE) in an Emergency Care Environment, Part 1
NCT06905613 ·Status: COMPLETED ·Phase: NA
-
Calibration and Evaluation of an Audio Pulse Oximeter Sensor (AudioOx) at Ascent and Descent From Simulated Altitude
NCT01732029 ·Status: COMPLETED ·Phase: NA
-
A Pilot Study to Assess the Feasibility and Tolerability of the AccuFlow Perfusion Sensor for Intrapartum Hemorrhage
NCT04370639 ·Status: COMPLETED ·Phase: NA
-
Remote Investigation and Assessment of Vital Signs
NCT05022264 ·Status: RECRUITING
-
Hypoxia Blood Validation in Multiple Pulse Oximeters
NCT00881829 ·Status: UNKNOWN
-
Noncontact Vital Sign Monitoring Using IR-UWB Radar
NCT03622996 ·Status: UNKNOWN
-
Respiration Rate V2.0 in Healthy Volunteers
NCT01804062 ·Status: COMPLETED
-
Pulse Contour Analysis and Tissue Oxymetry in Changing Vascular Tone
NCT00583687 ·Status: COMPLETED ·Phase: NA
-
Assessment of Stroke Volume and Cardiac Output in Response to Varying Heart Rates
NCT03446326 ·Status: RECRUITING ·Phase: NA
-
End-tidal Oxygen Can Reliably Predict the Arterial Partial Pressure of Oxygen Among Emergency Department Patients
NCT03842306 ·Status: COMPLETED
-
Cerebral Oximetry and NIRS in Cardiac Arrest Patients
NCT03769740 ·Status: UNKNOWN
-
Determination of the Accuracy of a Non-Invasive Continuous Blood Pressure Device
NCT01311128 ·Status: TERMINATED
-
Methods for the Measurement of Respiratory Rate
NCT02672007 ·Status: COMPLETED ·Phase: NA
-
SurePulse Oximeter - a Targeted Oxygenation Observation
NCT05756816 ·Status: COMPLETED ·Phase: NA
-
Perceptual, Hemodynamic and Cardiovascular Responses of Two Different BFR Training Protocols
NCT05145335 ·Status: COMPLETED ·Phase: NA