IntraOperative UltraSound Guided vs Wire Guided vs Magnetic Seed Guided Breast-Conserving Surgery for Non-palpable Tumors
NCT07185568 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 1302
Last updated 2026-03-24
Summary
This is a multi-center, randomized, open-label clinical trial that will enroll 1302 adult patients with non-palpable breast lesions. Participant eligible for the study will be randomized in a 1:1:1 ratio to one of the pre-surgery lesion localization: IOUS HydroMark™ (experimental arm A), magnetic Sirius Pintuition Seed® (experimental arm B) and the wire localization technique (control arm). The randomization will be stratified by lesion type (solid non-palpable (type B); non-solid non-palpable (e.g., microcalcification clusters, architectural distortive areas) (type C); post-NACT residual lesions (type D), and clinical center.
Conditions
- Breast Cancer
- Breast-Conserving Surgery
Interventions
- PROCEDURE
-
IOUS HydroMark™
IOUS HydroMarkTM allows marking the tissue during percutaneous breast biopsy. This is a sterile, single-use marker made of resorbable hydrogel, which expands upon contact with bodily fluids and is then gradually absorbed. The hydrogel is visible on ultrasound. Inside the hydrogel, there is a metallic spiral (titanium/steel) that remains permanently visible in radiographic and MRI examinations even after the hydrogel has been fully absorbed. The HydroMARK Breast Biopsy Site Marker is made of a resorbable hydrogel that expands with fluid and is then resorbed. The hydrogel material is visible under ultrasound. Embedded in the hydrogel is a coiled metallic wire that will be permanently visible under x-ray and MRI when the hydrogel is resorbed. The HydroMARK Biopsy Site Marker is a permanent implant and is not intended to be removed unless the marked tissue is determined to require surgical removal. The marker is supplied pre-loaded in applicator devices designed.
- PROCEDURE
-
Magnetic Sirius Pintuition Seed®
The Pintuition Localization System is intended as a magnetic soft tissue localization system. The magnetic Pintuition Seed is indicated for preoperative percutaneous implantation into soft tissue (glandular, fibrous or fatty tissue of breast; lymph nodes in the axillary and inguinal region; subcutaneous tissue and skeletal muscle tissue) for temporary marking (\<180 days) of a tissue of interest (e.g. tumor or a suspected lesion) indicated for surgical removal. Using the Pintuition Detector as magnetic guidance or, alternatively, image guidance (ultrasound or x-ray), the Pintuition Seed can be intra-operatively localized and removed together with the tissue of interest.
- PROCEDURE
-
Wire localization (WL)
Single-use, repositionable needle for preoperative localization of breast nodules with a single hook, equipped with a depth limiter. Designed for the localization of non-palpable breast lesions in the preoperative phase. It includes a fixation clamp to stabilize the positioning of the wire.
Sponsors & Collaborators
-
Istituto Oncologico Veneto IRCCS
lead OTHER
Principal Investigators
-
Massimo Ferrucci, MD PhD · Veneto Institute of Oncology IRCCS
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- FEMALE
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2026-05-04
- Primary Completion
- 2027-09-30
- Completion
- 2027-12-31
Countries
- Italy
Study Locations
More Related Trials
-
Quality of Life and Cosmetic Outcomes of Breast-Conserving Surgery According to Localization Method
NCT06186011 ·Status: RECRUITING ·Phase: NA
-
ROLL Versus Magnetic Seed for Preoperative Localization of Non-palpable Breast Lesion: Comparison Between Techniques.
NCT05942092 ·Status: ACTIVE_NOT_RECRUITING
-
Breast Cancer Locator Guided vs. Wire Localized Partial Mastectomy for Breast Cancer
NCT04397185 ·Status: COMPLETED ·Phase: NA
-
International Prospective REgistry on Pre-pectorAl Breast REconstruction
NCT05817175 ·Status: RECRUITING
-
The Oncological Safety and Cosmetic Outcome of Areola Sparing Mastectomy : a Single Arm, Prospective, Cohort Study
NCT03105570 ·Status: UNKNOWN ·Phase: NA
-
Radiofrequency Identification Technology in Locating Non-palpable Breast Lesions in Patients Undergoing Surgery
NCT03202472 ·Status: COMPLETED ·Phase: NA
-
Surgery With or Without Lymph Node Removal in Treating Older Women With Stage I Breast Cancer
NCT00002720 ·Status: COMPLETED ·Phase: PHASE3
-
Prospective Clinical Investigation Comparing Standard Wound Closure Technique With Drains (Control) to Standard Wound Closure Techniques With TissuGlu® and No Drains (Test) in Mastectomy
NCT02958449 ·Status: COMPLETED ·Phase: NA
-
Comparing the Safety and Cosmetic Outcomes Between Laparoscopic Versus Traditional Open Breast-conserving Surgery
NCT06671249 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Local and Regional Radiotherapy for Nipple Sparing Mastectomy With Implant
NCT05213962 ·Status: ENROLLING_BY_INVITATION
-
Scarless Advanced Breast Extended Oncoplasty: The ScarABEO Study
NCT06906237 ·Status: RECRUITING
-
A Trial of a New Magnetic Breast Marking Clip
NCT02378558 ·Status: TERMINATED ·Phase: NA
-
Tumour Localisation With Magnetic Clip Before Neoadjuvant Chemotherapy.
NCT06463600 ·Status: RECRUITING ·Phase: NA
-
"The Efficacy of 'Radioguided Occult Lesion Localization' (ROLL) Versus 'Wire-guided Localization' (WGL) in Breast Conserving Surgery for Non-palpable Breast Cancer: a Randomized Clinical Trial"
NCT00539474 ·Status: COMPLETED ·Phase: PHASE3
-
Ideal Marker for Targeted Axillary Dissection
NCT04580251 ·Status: COMPLETED
-
Locoregional Control With Radiotherapy of Breast Cancer Patients With MACrometastases Treated With MAstectomy (MACMA)
NCT06378294 ·Status: ACTIVE_NOT_RECRUITING
-
Reducing Pain and Disability After Breast Cancer Surgery
NCT01089933 ·Status: COMPLETED ·Phase: NA
-
Post Market Clinical Follow Up to "Patient Reported Outcome" Using a Titanised Polypropylene Mesh (TiLOOP® Bra Pocket)
NCT03868514 ·Status: COMPLETED
-
Robot-assisted vs. Open Nipple-sparing Mastectomy With Immediate Breast Reconstruction
NCT05490433 ·Status: RECRUITING ·Phase: NA
-
Electrosurgical Bipolar Systems Versus Conventional Electrocautery After SLNBx
NCT06426810 ·Status: RECRUITING ·Phase: NA
-
Study of the Outcomes of Intraoperative Margin Assessment With MarginProbe
NCT02456649 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Ultrasonic Scissors and Diathermy for Axillary Clearance in Breast Cancer Patients
NCT05901064 ·Status: RECRUITING ·Phase: NA
-
Ultrasound Guided Percutaneous Microwave Ablation for Breast Lesions
NCT02860104 ·Status: UNKNOWN ·Phase: PHASE2/PHASE3
-
Surgical and Patient Reported Outcomes of Robotic Nipple-Sparing Mastectomy
NCT04151368 ·Status: SUSPENDED ·Phase: NA
-
The Impact of Surgeon-Interpreted Intraoperative Margin Assessment During Breast Conserving Surgery on Postoperative Treatment
NCT07140965 ·Status: SUSPENDED