Trial to Assess Non-inferiority of an Orbital Atherectomy Only Versus a Calcium-tailored Debulking Approach
NCT07105930 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 310
Last updated 2026-03-27
Summary
Some patients with coronary artery disease have severely calcified vessels. In these cases, placing a stent - a small tube that helps keep the artery open - can be very difficult. Calcium build-up in the artery wall may prevent the stent from expanding properly, increasing the risk of complications or failure of the treatment.
To prepare these vessels before stenting, doctors use special techniques to modify or remove the calcium. These techniques are known as plaque modification strategies and can include devices such as atherectomy systems, scoring balloons, or intravascular lithotripsy. However, there is no clear standard as to which strategy is best.
Purpose of the Study:
This study compares two different approaches to treating calcified coronary arteries before stenting:
* A uniform approach using only the orbital atherectomy system (Diamondback 360®, Abbott), which sands away the calcium with a rotating crown
* A tailored approach, where the operator chooses from various available methods (e.g., rotational atherectomy, scoring or cutting balloons, or shockwave therapy) based on the patient's specific type of calcium The goal is to determine whether the uniform orbital atherectomy approach is not worse (non-inferior) than the individualized method when it comes to how well the stent expands inside the artery.
This is a randomized, controlled clinical trial. Patients will be randomly assigned to one of the two groups.
Randomization ensures fair comparison between both groups. The decision to implant a stent and to use additional techniques is at the discretion of the interventional cardiologist.
Conditions
- Orbital Atherectomy
Interventions
- DEVICE
-
Debulging approach using the orbital atherectomy system
A uniform approach using only the orbital atherectomy system (Diamondback 360®), which sands away the calcium with a rotating crown
- PROCEDURE
-
Debulging using rotational atherectomy, scoring or cutting balloons, or shockwave therapy
A tailored approach, where the operator chooses from various available methods based on the patient's specific type of calcium
Sponsors & Collaborators
-
IHF GmbH - Institut für Herzinfarktforschung
lead OTHER
Principal Investigators
-
Marco Ochs, PD Dr. · Universitäres Herz- und Gefäßzentrum Frankfurt ZIM - Med. Clinic 3 - Cardiology and Angiology
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2025-10-30
- Primary Completion
- 2027-01-31
- Completion
- 2027-03-31
Countries
- Germany
Study Locations
More Related Trials
-
Stentys Coronary Stent System Clinical Trial in Patients With Acute Myocardial Infarction
NCT01732341 ·Status: TERMINATED ·Phase: PHASE3
-
DCB vs DES for Severe Coronary Calcification After Optimal Modification Assessed by QFR
NCT07277114 ·Status: RECRUITING ·Phase: NA
-
ILUMIEN IV: OPTIMAL Percutaneous Coronary Intervention (PCI)
NCT03507777 ·Status: COMPLETED ·Phase: NA
-
Thin Strut Sirolimus-eluting Stent in All Comers Population vs Everolimus-eluting Stent
NCT02870140 ·Status: COMPLETED ·Phase: NA
-
Study of the Orsiro Drug Eluting Stent System
NCT01356888 ·Status: UNKNOWN ·Phase: NA
-
Optical Coherence Tomography Guided Percutaneous Coronary Intervention With Stent Implantation
NCT02272283 ·Status: COMPLETED ·Phase: NA
-
The Value of IVL Compared To OPN Non-Compliant Balloons for Treatment of RefractorY Coronary Lesions (VICTORY) Trial
NCT05346068 ·Status: RECRUITING ·Phase: NA
-
Absorb Bioresorbable Scaffold vs. Drug Coated Balloon for Treatment Of In-Stent-Restenosis
NCT03529006 ·Status: UNKNOWN ·Phase: NA
-
Intracoronary Stenting and Restenosis - Randomized Trial of Drug-eluting Stent Implantation or Drug-coated Balloon Angioplasty According to Neointima Morphology in Drug-eluting Stent Restenosis 5
NCT05544864 ·Status: RECRUITING ·Phase: NA
-
Clinical Performance of CRE8 Drug Eluting Stent in All Comer Population
NCT01556126 ·Status: COMPLETED ·Phase: NA
-
Efficacy and Safety of New Generation Drug Eluting Stents Associated With an Ultra Short Duration of Dual Antiplatelet Therapy. Design of the Short Duration of Dual antiplatElet Therapy With SyNergy II Stent in Patients Older Than 75 Years Undergoing Percutaneous Coronary Revascularization.
NCT02099617 ·Status: COMPLETED ·Phase: NA
-
Stenting With or Without Coating Compared With Angioplasty in Non-benestent Disease
NCT00192881 ·Status: UNKNOWN ·Phase: NA
-
Adhesiveness of Coronary Drug-Eluting Stents to the Delivery Balloon-Catheter: A Randomized Comparison
NCT00279006 ·Status: UNKNOWN ·Phase: NA
-
Ultrathin Strut Sirolimus-eluting Stent With Bioabsorbable Polymer in Patients Receiving Chronic Oral Anticoagulation
NCT06863155 ·Status: RECRUITING
-
The TRIMAXX Coronary Stent Trial
NCT00596661 ·Status: COMPLETED ·Phase: PHASE1
-
Efficacy CompariSon of Pre-stenting Atherectomy Versus Scoring ballooN for calcifieD Coronary Lesions Coronary Lesions
NCT02819531 ·Status: UNKNOWN ·Phase: NA
-
Efficacy Study of Stenting, Paclitaxel Eluting Balloon or Atherectomy to Treat Peripheral Artery Disease
NCT00986752 ·Status: UNKNOWN ·Phase: PHASE4
-
Safety and Effectiveness of the Orsiro Sirolimus Eluting Coronary Stent System in Subjects With Coronary Artery Lesions
NCT02389946 ·Status: COMPLETED ·Phase: NA
-
Endothelial Progenitor Cells-capture Stents in Acute Coronary Syndromes
NCT00494247 ·Status: COMPLETED ·Phase: PHASE4
-
Observational Study to Evaluate Short and Long-term Safety of the ABSORB Scaffold
NCT02066623 ·Status: COMPLETED
-
Xience or Vision Stent Management of Angina in the Elderly
NCT02198716 ·Status: COMPLETED ·Phase: NA
-
Treatment of Coronary In-Stent Restenosis
NCT01735825 ·Status: COMPLETED ·Phase: NA
-
Drug-Coated Balloon Coronary Angioplasty Versus Stenting for Treatment of Disease Adjacent to a Chronic Total Occlusion.
NCT04881812 ·Status: UNKNOWN ·Phase: NA
-
10-Years Follow-up of the EXAMINATION Trial
NCT04462315 ·Status: COMPLETED
-
The Study to Assess AMI Treated With Balloon Angioplasty.
NCT00232830 ·Status: COMPLETED ·Phase: PHASE3