Research Based on IOLMaster700 Cataract Diagnosis and Classification System
NCT07022444 · Status: NOT_YET_RECRUITING · Type: OBSERVATIONAL · Enrollment: 2000
Last updated 2025-06-15
Summary
Cataract is a major cause of blindness due to eye diseases. Methods for evaluating the degree of lens opacification in cataracts are divided into subjective and objective methods. The commonly used subjective method is the Lens Opacification Classification System (LOCS Ⅲ), while the objective methods mainly include the Dysfunctional Lens Index (DLI) of the Ray Tracing aberration analysis system, the PNS score of the Pentacam anterior segment analysis system, etc. Subjective diagnosis may lead to certain misjudgments, which have affected clinical diagnosis and treatment. There is an urgent need to add objective diagnostic measures to assist clinical work. The Scanning Source Optical Coherence Tomography (SS - OCT) biometer - IOL Master 700 forms an OCT imaging of the eye based on the swept - source optical coherence tomography (OCT) biometric technology. It can visually show the longitudinal section of the entire lens, and the clear display of the patient's lens tomographic OCT image is obtained through image visualization measurement.
The main purpose of this study is to analyze the lens images obtained by the IOLmaster 700. Based on the current mainstream algorithm models such as ResNet - 34 and XGBoost, develop a heterogeneous accelerated artificial intelligence algorithm according to our research needs to accurately calculate the degree of lens opacification. And write image analysis software by ourselves to automatically calculate the required indicators and output them. Establish a heterogeneous accelerated artificial intelligence - assisted lens opacification grading and prediction system, supporting software for biometer equipment, and a cataract lens image database. The software provides online service functions, and all researchers can use the image analysis function of the software after logging in, truly realizing the sharing of large instrument supporting software operations. Thereby improving the accuracy and efficiency of clinical diagnosis and treatment, the prognostic prediction level of patients after cataract surgery, guiding clinical diagnosis and treatment more accurately, and at the same time, it can be used as a tool for community screening.
Conditions
- Cataract
- Artificial Intelligence (AI)
Interventions
- DEVICE
-
IOL-MASTER 700
patients who were diagnosed cataract would go through tests with IOL-MASTER 700 to achieve ocular biometry parameters.
Sponsors & Collaborators
-
Shanghai 10th People's Hospital
lead OTHER
Eligibility
- Min Age
- 40 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2025-06-15
- Primary Completion
- 2025-08-31
- Completion
- 2025-12-31
More Related Trials
-
Intraocular Lens Calculation Using Artificial Intelligence
NCT07202767 ·Status: NOT_YET_RECRUITING
-
IOLMASTER 700 Central Topography Workflow Study.
NCT04875247 ·Status: COMPLETED
-
A Multi Focal Visual Outcome Study Using Different Near Additions
NCT00960700 ·Status: TERMINATED
-
The Application of Lens Dysfunction Index (DLI) in the Timing of Age-related Cataract Surgery
NCT04711395 ·Status: UNKNOWN
-
Neural Compensation, Visual Function and Visual Quality After Monofocal or Multifocal Intraocular Lens Implantation
NCT02644720 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of Visual Acuity in Myopic Cataract Patients Using Trifocal Intraocular Lens
NCT04927117 ·Status: UNKNOWN
-
Dysfunctional Lens Index Serves as a Novel Surgery Decision Maker for Age-related Cataracts
NCT03340389 ·Status: UNKNOWN ·Phase: NA
-
Performance of Large Language Models for Structured Recognition and Refractive Prediction
NCT07183891 ·Status: RECRUITING
-
Zeiss® IOLMaster 700 Corneal Topography Module Comparison With Schwind's Sirius Corneal Topography®
NCT05414773 ·Status: UNKNOWN ·Phase: NA
-
Refractive Outcomes Utilizing Two SS-OCT Biometers for IOL Power Calculations
NCT06801678 ·Status: RECRUITING
-
Multifocal vs Monofocal IOL in Congenital Cataract Surgery
NCT04872829 ·Status: COMPLETED
-
Clinical Investigation of the Multifocal IOL POD F GF in Cataracteous Eyes
NCT04699266 ·Status: COMPLETED ·Phase: NA
-
Development of an IT Tool Able to Identify Ocular Conditions
NCT05973617 ·Status: WITHDRAWN
-
Assessment of Visual Function and Optics in Intraocular Lenses
NCT01654159 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Prospective Clinical Study of Preoperative and Postoperative Unilateral Mild Cataract Patients
NCT04266847 ·Status: UNKNOWN ·Phase: NA
-
Visual Performance of Functional Intraocular Lenses in Cataracts
NCT05581888 ·Status: UNKNOWN ·Phase: NA
-
CAtaract ASSessment of IntrOcular Lens Objective PErformancE
NCT06168617 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Clinical Evaluation of the FluidVision Accommodating Intraocular Lens (AIOL)
NCT02049567 ·Status: COMPLETED ·Phase: NA
-
Bicentric Clinical Investigation to Assess Safety and Performance of LuxHighAdd IOL
NCT06446817 ·Status: RECRUITING ·Phase: NA
-
AcrySof® IQ ReSTOR® +2.5 D Multifocal Intraocular Lens (IOL) Model SN6AD2 [SV25T0] in Japan
NCT01605877 ·Status: COMPLETED ·Phase: NA
-
Patients Outcomes of a Monofocal Intraocular Lens Designed for Monovision
NCT06528678 ·Status: COMPLETED
-
Visual Performance of Four Types of Multifocal Intraocular Lenses
NCT03454334 ·Status: TERMINATED ·Phase: NA
-
Multi-formula Optimization of Second Eye Refinement According to Direction of the Prediction Error of the First Eye
NCT02270879 ·Status: COMPLETED
-
Evaluation of Toric Intraocular Lens(IOL) Combined With Capsular Tension Ring(CTR) in Patients With Cataract Combined With High Myopia
NCT06571773 ·Status: ACTIVE_NOT_RECRUITING
-
Potential Risk Factors and Predictive Model Construction of OBL During SMILE
NCT06577012 ·Status: COMPLETED