Dysfunctional Lens Index Serves as a Novel Surgery Decision Maker for Age-related Cataracts
NCT03340389 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 60
Last updated 2017-11-13
Summary
To study the correlations among the dysfunctional lens index (DLI), Lens Opacities Classification System III (LOCS III) nuclear opalescence grading score, preoperative corrected distance visual acuity (CDVA), the objective scatter index (OSI) and Scheimpflug based average lens density in age-related cataracts. To investigate the potential of the DLI as a novel surgery decision maker via the Operating Characteristic (ROC) curve analysis.
Conditions
- Age-related Cataract
Interventions
- PROCEDURE
-
a ray-tracing aberrometry
The Dysfunctional Lens Index is obtained by a ray-tracing aberrometry
Sponsors & Collaborators
-
Wenzhou Medical University
lead OTHER
Study Design
- Allocation
- NA
- Purpose
- SCREENING
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2017-09-01
- Primary Completion
- 2018-05-01
- Completion
- 2018-12-01
Countries
- China
Study Locations
More Related Trials
-
Study of Subluxation Lens Biometrics and Postoperative Intraocular Lens Stability
NCT04685122 ·Status: UNKNOWN
-
Visual Performance of Multifocal Intraocular Lenses
NCT04913792 ·Status: UNKNOWN
-
Assessment of Visual Function and Optics in Intraocular Lenses
NCT01654159 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Spherical Aberration and Contrast Sensitivity in IOLs
NCT00576485 ·Status: COMPLETED ·Phase: PHASE4
-
Full 3D Eye Modeling in the Diagnosis and Treatment of Lens Diseases With Eye Structures Disorders
NCT07321769 ·Status: RECRUITING
-
Measurement of Refractive SE Following Implantation of LS313 MF30 IOL
NCT03292614 ·Status: COMPLETED
-
Effective Lens Position After Cataract Surgery
NCT04443101 ·Status: UNKNOWN
-
Evaluation Of Deep Anterior Lamellar Keratoplasty By Anterior Segment Ocular Coherence Tomography
NCT05345652 ·Status: UNKNOWN
-
Wavefront Analisys and Contrast Sensitivity of Spherical and Aspherical Intraocular Lenses
NCT00347243 ·Status: COMPLETED ·Phase: PHASE4
-
Subjective and Objective Refraction in Pseudophakic Patients
NCT04319497 ·Status: COMPLETED ·Phase: NA
-
Study on the Diagnostic Efficacy of ICL Selection and Prediction Depth Model Based on Eye Images
NCT06669728 ·Status: RECRUITING
-
Evaluation of a Monofocal Intraocular Lens
NCT06428955 ·Status: RECRUITING ·Phase: PHASE4
-
CAtaract ASSessment of IntrOcular Lens Objective PErformancE
NCT06168617 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Comparative Study of Two Multifocal Intraocular Lens With Different Add Power
NCT02424162 ·Status: COMPLETED ·Phase: NA
-
The Influence of Different Preoperative Decision Schemes on the Visual Quality After Toric Intraocular Lens Implantation
NCT04006912 ·Status: UNKNOWN ·Phase: NA
-
Multifocals and Accommodating/Bilateral Implantation of Different Multifocal Intraocular Lens (IOLs)
NCT00934960 ·Status: TERMINATED
-
Reduction of Corneal Astigmatism With Toric Intraocular Lens Implantation in Congenital Cataract
NCT02040129 ·Status: COMPLETED ·Phase: NA
-
Visual Outcomes of a Segmental Refractive Multifocal Intraocular Lens
NCT03452969 ·Status: COMPLETED
-
Evaluation of the Rotational Stability of The AcrySof Toric Intraocular Lens in the Capsular Bag in High Myopic Subjects
NCT01351233 ·Status: COMPLETED ·Phase: NA
-
Effect of 1.8-mm Steep-axis Clear Corneal Incision on the Posterior Corneal Astigmatism in Candidates for Toric IOL Implantation
NCT04924231 ·Status: COMPLETED
-
Aberrometry and Straylight Measurements as an Indication for Cataract Surgery
NCT06257914 ·Status: ENROLLING_BY_INVITATION
-
Evaluating Presbyopia-Correcting IOLs in Complex Cataract Cases With Anterior Segment Abnormalities
NCT07321756 ·Status: RECRUITING ·Phase: NA
-
Prospective Clinical Study of Unilateral or Bilateral Implantation of Intraocular Lens in Cataract Patients
NCT04265820 ·Status: UNKNOWN ·Phase: NA
-
The Impact of Light Conditions on the Efficacy of Multifocal Intraocular Lens Implantation in Activities of Daily Living
NCT05359380 ·Status: COMPLETED
-
Clinical Study to Evaluate the RxSight Light Adjustable Lens With the Light Delivery Device in Subjects With Preoperative Corneal Astigmatism
NCT03771352 ·Status: COMPLETED ·Phase: NA