Towards a More Standardized Bicuspid Aortic Valve Repair: Rationale and Design of CONTOUR Trial - a Randomized Trial
NCT06869954 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 100
Last updated 2025-10-07
Summary
Background: Between one-third and one-half of patients with bicuspid aortic valve (BAV) disease develop significant aortic regurgitation (AR) at a young age, leading to cardiomyopathy and heart failure. Aortic valve repair is an evolving and still underused strategy in BAV patients with AR. The lack of sufficient standardization remains the main limitation of current repair techniques, resulting in an increased risk of AR recurrence and reoperation. The most controversial issue is the stabilization of the BAV annulus. The CONTOUR trial aims to compare two different BAV annuloplasty concepts in a prospective randomized study.
Methods: CONTOUR is a multicenter, randomized controlled trial designed to enroll 100 consecutive BAV patients with AR across four sites in Germany. BAV AR patients with an asymmetric configuration and without concomitant root aneurysm will be randomized 1:1 to undergo aortic valve repair using an internal HAART 200 annuloplasty device (i.e., INTERNAL group) (n=50) or external annuloplasty (i.e., double external ring annuloplasty) in the EXTERNAL group (n=50). 4D flow MRI will be performed preoperatively (t1), postoperatively at discharge (t2), and at 1-year follow-up (t3) for rater-blinded assessment of hemodynamic profiles (i.e., flow eccentricity) and regurgitation fraction at the MRI core-lab. Two hierarchically ordered primary endpoints will be considered: (1) postoperative reduction of flow eccentricity at hospital discharge and (2) regurgitation fraction (%) at 1-year follow-up.
Discussion: The CONTOUR trial is designed to test the hypothesis that an internal annuloplasty device, creating a completely symmetric post-repair BAV geometry, achieves superior aortic valve repair outcomes compared to external annuloplasty. If our hypothesis is confirmed, our study will significantly influence aortic valve repair practice and contribute to the refinement of guideline recommendations in the management of BAV patients with AR.
Conditions
- Bicuspid Aortic Valve (BAV)
- Aortic Regurgitation Disease
Interventions
- DEVICE
-
Internal HAART 200 annuloplasty device
For the INTERNAL group, the HAART 200 internal annuloplasty ring (CorCym, London, UK), specifically designed for BAV morphology, will be used for all patients. Intraoperative sizing for the internal ring is based on the geometric orientation and size of the non-fused cusp. A standard ball sizer is used for the measurement of the non-fused cusp to assess commissural orientation and surface area of the non-fused cusp. Sizing typically results in values of 23mm or 25mm, with other sizes being very rare. Both commissural posts of the internal annuloplasty ring are fixed using two subcommissural sutures \[10\]. A modified technique for placement of transannular looping sutures will be used to secure the internal ring in the subannular position, as recently published \[21\]. Cusp maneuvers (i.e., shaving, thinning of the raphe, central plication sutures) will be performed to achieve an effective height of 8-10 mm. When indicated (i.e., for ascending aortic diameter \> 45mm or aiming to achieve th
- DEVICE
-
double external ring annuloplasty
For the EXTERNAL group, all study patients will undergo double external Dacron ring annuloplasty by simultaneous stabilization of the basal virtual ring and the STJ \[22\]. The surgical technique of double external annuloplasty, detailed by the Lansac group \[22\], involves aortic annulus sizing with a Hegar dilator to select the sizes of the external subannular annuloplasty ring and STJ ring (same size). After deep dissection of the aortic root, 6-7 2-0 pledgeted U sutures are placed circumferentially at the level of the virtual basal ring for external subannular ring implantation. Cusp maneuvers are performed similar to those in the INTERNAL group. STJ stabilization is achieved using an external STJ ring or ascending aortic replacement with a vascular tube graft (e.g., in cases with a high offspring of the right coronary artery). Treatment of the tubular ascending aorta is identical to the INTERNAL group.
Sponsors & Collaborators
-
Universitätsklinikum Hamburg-Eppendorf
collaborator OTHER -
University Clinic Frankfurt
collaborator OTHER -
Heart Center Leipzig - University Hospital
collaborator OTHER -
University Hospital Augsburg
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2025-05-21
- Primary Completion
- 2027-06-30
- Completion
- 2027-06-30
Countries
- Germany
Study Locations
More Related Trials
-
REpositionable Versus BallOOn-expandable Prosthesis for Trans-catheter Aortic Valve Implantation
NCT02668484 ·Status: COMPLETED ·Phase: NA
-
Everyday Practice With Transcatheter Aortic Valve Implantation
NCT02289339 ·Status: COMPLETED
-
TAVR: The Impact of Prothesis Positioning on Valvular and Coronary Hemodynamics
NCT06896227 ·Status: RECRUITING ·Phase: NA
-
ChAracterization of Patients and Treatment OUtcomes in Severe Tricuspid Regurgitation
NCT06838611 ·Status: RECRUITING
-
TAVIS Registry - Trilogy Heart Valve System for Management of Patients With Aortic Valve Disease
NCT05536310 ·Status: NOT_YET_RECRUITING
-
ARTIST: Aortic Regurgitation Trial Investigating Surgery Versus Trilogy™
NCT06608823 ·Status: RECRUITING ·Phase: NA
-
EASE TRICUSPID Expertise-based Assessment Study on Clinical Efficacy of Contour 3D® in TRICUSPID Valve Annuloplasty
NCT01532921 ·Status: COMPLETED
-
Feasibility, Safety, and Effectiveness of the ACURATE neo2 Transcatheter Heart Valve for Severe Bicuspid Aortic Stenosis
NCT06212050 ·Status: ENROLLING_BY_INVITATION
-
German Registry for Transcatheter Tricuspid Valve Interventions
NCT04653428 ·Status: RECRUITING
-
Bicuspid Aortic Valve Replacement: Evaluation of Transcatheter Versus Surgery-Pilot Trial
NCT06817148 ·Status: RECRUITING ·Phase: NA
-
TriRec - Trileaflet Reconstruction of the Aortic Valve With Autologous Pericardium
NCT03600662 ·Status: RECRUITING ·Phase: NA
-
TARGET 2.0 Study: Safety and Performance of the Cardiovalve TR Replacement System
NCT07334691 ·Status: RECRUITING ·Phase: NA
-
Post-market Clinical Monitoring of the Safety and Efficacy of the Aortic Valve Bioprothesis
NCT05998694 ·Status: RECRUITING
-
accuRate Evaluation of Benefit With Optimal Medical Treatment With or Without Transcatheter Valve Repair of PARADOXical Low Flow Low Gradient Aortic Stenosis
NCT03863132 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
4D- Flow- MRI After Aortic Valve Surgery
NCT04223713 ·Status: UNKNOWN ·Phase: NA
-
Randomized Trial of TAVI vs. SAVR in Patients With Severe Aortic Valve Stenosis at Low to Intermediate Risk of Mortality
NCT03112980 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Treatment of Concomitant Mitral Regurgitation by Mitral Valve Clipping in Patients With Successful Transcatheter Aortic Valve Implantation.
NCT04009434 ·Status: UNKNOWN ·Phase: NA
-
Aortic Stenosis - Prognosis, Risk and Outcomes
NCT06863883 ·Status: NOT_YET_RECRUITING
-
Indexed Aortic Area in Bicuspid Aortic Valve Aortopathy
NCT04756778 ·Status: COMPLETED
-
Study of Transcatheter Tricuspid Annular Repair
NCT03692598 ·Status: RECRUITING ·Phase: NA
-
Treatment of Tricuspid Valve Regurgitation in Patients Undergoing Left Ventricular Assist Device Implantation Study
NCT03775759 ·Status: COMPLETED ·Phase: NA
-
Feasibility of Transcatheter Aortic Valve Replacement in Low-Risk Patients With Symptomatic, Severe Aortic Stenosis
NCT02628899 ·Status: COMPLETED ·Phase: NA
-
A Study of Chinese Congenital Bicuspid Aortic Valve
NCT06802016 ·Status: RECRUITING
-
RanDOmized stUdy Comparing Both Latest Generation Self-Expanding Valves and a Minimalist approaCH vs. Standard Of Care In transCathEter Aortic Valve Implantation
NCT05036018 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
European Association of Cardiovascular Imaging Multiple and Mixed Valvular Disease Study
NCT06235385 ·Status: RECRUITING