Indexed Aortic Area in Bicuspid Aortic Valve Aortopathy
NCT04756778 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 69
Last updated 2021-02-16
Summary
This study aims to determine the relationship between the cross-sectional aortic area/patient height ratio (indexed aortic area) and absolute aortic diameter in proximal thoracic aortic aneurysms associated with a bicuspid valve. This will shed light on whether aneurysms with smaller diameters than those recommended for surgical intervention by guidelines are still at risk of aortic complications attending an abnormally high indexed aortic area.
Conditions
- Thoracic Aortic Aneurysm
- Bicuspid Cardiac Valve
Interventions
- PROCEDURE
-
Aortic surgery +/- aortic valve replacement
Replacement of aneurysmal proximal thoracic aorta +/- replacement of diseased bicuspid aortic valve
Sponsors & Collaborators
-
St. George's Hospital, London
lead OTHER
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2017-01-27
- Primary Completion
- 2017-05-15
- Completion
- 2017-08-15
Countries
- United Kingdom
Study Locations
More Related Trials
-
Changes of Ascending Aortic Diameter in Patients Undergoing Transcatheter Aortic Valve Replacement
NCT05739253 ·Status: RECRUITING
-
Efficacy of Self-expandable and Balloon-expandable Valves in Patients With Ascending Aortic Dilation
NCT06743568 ·Status: RECRUITING ·Phase: NA
-
The Early Valve Replacement in Severe ASYmptomatic Aortic Stenosis Study
NCT04204915 ·Status: RECRUITING ·Phase: NA
-
Conventional Versus Mini-Sternotomy for Aortic Valve Surgery
NCT00221663 ·Status: TERMINATED ·Phase: PHASE2/PHASE3
-
Neurocognitive Assessment in TAVI
NCT06120946 ·Status: COMPLETED
-
Sizing-sTrategy of Bicuspid AoRtic Valve Stenosis With Transcatheter Self-expandable Valve
NCT02541877 ·Status: UNKNOWN ·Phase: PHASE3
-
Outcomes of Surgery of Aortic Valve
NCT04277572 ·Status: UNKNOWN
-
MRI in Randomised Cohorts of Asymptomatic AS
NCT05178368 ·Status: RECRUITING
-
Cohort Observing Mechanisms, Progression and Sequelae of Valvular Heart Disease
NCT07267117 ·Status: RECRUITING
-
Early Valve Replacement Guided by Biomarkers of LV Decompensation in Asymptomatic Patients With Severe AS
NCT03094143 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Coronary Artery Bypass Grafting With Ascending Aortic Replacement
NCT07071857 ·Status: COMPLETED ·Phase: NA
-
Early Outcomes of Concomitant Transcatheter Aortic Valve Implantation and Off-pump Coronary Artery Bypass Grafting in Management of Severe Symptomatic Aortic Stenosis and Coronary Artery Disease
NCT04525339 ·Status: UNKNOWN
-
Outcomes for Patients With Ascending Aortic Dilation Who Underwent TAVR
NCT07148973 ·Status: COMPLETED
-
A Multicentre Retrospective Study on Bicuspid Aortic Valve
NCT05818722 ·Status: RECRUITING
-
Regression of Myocardial Fibrosis After Aortic Valve Replacement
NCT02174471 ·Status: COMPLETED
-
Mechanisms of Excess Risk in Aortic Stenosis
NCT04627987 ·Status: RECRUITING
-
Clinical Outcome of Patients With Low-gradient Severe Aortic Stenosis
NCT02010177 ·Status: SUSPENDED
-
Cardiac Amyloidosis in Patients With Aortic Stenosis
NCT07170306 ·Status: NOT_YET_RECRUITING
-
The Role of Ischaemia-reperfusion Injury in the Pathogenesis of Muscle Wasting After Thoracic Aortic Surgery
NCT03354767 ·Status: COMPLETED
-
Portico Valve-in-Valve Retrospective Registry
NCT05002088 ·Status: COMPLETED
-
Retrospective Analysis of Procedural Aspects of Transcatheter Aortic Valve Implantation (TAVI) on Peri-procedural Stroke
NCT02711540 ·Status: UNKNOWN
-
Interest of Pulse Wave Velocity Measurement as a Predictor of Severity of Aortic Stenosis
NCT03140735 ·Status: WITHDRAWN ·Phase: NA
-
Preoperative CT-imaging with Patient-specific Computer Simulation in Transcatheter Aortic Valve Replacement
NCT05788770 ·Status: RECRUITING ·Phase: NA
-
EndoVascular Aortic Dissection Early vs Delayed
NCT07143071 ·Status: ACTIVE_NOT_RECRUITING
-
Risk Factors Associated With Calcification of the Aortic Valve
NCT00375336 ·Status: UNKNOWN