Assessment of a Wearable Ultrafiltration Device
NCT06832696 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 18
Last updated 2026-04-29
Summary
Kidney failure is common. In some people the ability of the kidneys to clean poisons out of the blood gets so low they need to be hooked up to a machine three times a week to do it for them. This is called dialysis. Unfortunately, although this treatment removes those waste products, people who need dialysis die much more often than people who don't need dialysis. Dialysis causes extreme stress on the body and leads to many organs being damaged.
Removing fluid from the body quickly causes the equivalent of repeated little heart attacks or little strokes in the brain. Many patients struggle to tolerate having all the fluid that they have drunk since their last dialysis session removed- without unpleasant symptoms of dangerously low blood pressure (which makes the damage worse).
Dialysis treatments can be done more slowly or more often, but that means having to spend a lot more time at the hospital and is difficult for the health system to be able to provide the extra treatment time.
Could extra fluid be removed in between dialysis sessions? Up to now there has not been a way to effectively do this. Investigators have now designed and built an entirely new, very small and very simplified, device that can do part of what a dialysis machine does. It doesn't clean the blood or replace the need for conventional dialysis sessions, but it can provide additional and gentle removal of fluid which wasn't able to be taken off during a standard treatment session.
If this study is successful, it will be the first time that a wearable device has been successfully built and used to take off extra fluid when dialysis patients are not in the hospital. The ability to do this opens up the possibility of, 1) helping to treat patients (both making people feel better and live longer) who can't tolerate getting off all the fluid in the short 3-4 hours they are on the dialysis machine in the hospital, and 2) helping patients who feel OK having the fluid taken off but are silently being subjected to damage to their organs due to the rapid removal, have reduced damage.
Conditions
- Hemodialysis
- Ultrafiltration
Interventions
- DEVICE
-
RUF-D
We have developed a simplified fluid removal device (RUF-D) to address the challenges that patients face with being unable to remove the fluid they need with standard dialysis. Participants 01-09 will receive one week of baseline observation (three HD treatments) with two weeks of supervised intervention using RUF-D post HD on Mondays and Wednesdays for up to six hours (total three-week study). Participants 10-18 will receive one week of baseline observation, two weeks of intervention (identical to cohort one above), with an additional week of intervention (total four weeks) where participants will be fitted with the RUF-D (ensuring functionality) before going home with the device in operation for up to six hours twice weekly.
Sponsors & Collaborators
-
London Health Sciences Centre Research Institute OR Lawson Research Institute of St. Joseph's
lead OTHER
Principal Investigators
-
Dr. Christopher McIntyre, MBBS DM · London Health Sciences Centre
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2026-07-01
- Primary Completion
- 2027-12-31
- Completion
- 2027-12-31
Countries
- Canada
Study Locations
More Related Trials
-
Effect of Expanded Dialysis on Patient Reported Symptoms Using LEVIL
NCT03640858 ·Status: COMPLETED ·Phase: NA
-
Reduction Ratio and Clearance During Hemodialysis With MCO-filter Compared to HDF With Standard High-flux Filter
NCT03437538 ·Status: COMPLETED ·Phase: NA
-
Product Evaluation for the Effectiveness of the ClearGuard™ HD End Cap
NCT02604264 ·Status: COMPLETED ·Phase: NA
-
A Comparative Study of Two Kinds of Hemodialysis Filters
NCT05899283 ·Status: COMPLETED ·Phase: NA
-
12 Weeks of Hemodialysis With Medium Cut-Off Filter Compared to Hemodiafiltration With Standard High-flux Filter.
NCT03416192 ·Status: WITHDRAWN ·Phase: NA
-
A Performance Analysis of the Peritoneal Ultrafiltration (PUF) Achieved With the Carry Life® UF
NCT03724682 ·Status: COMPLETED ·Phase: NA
-
Product Evaluation for the Effectiveness of the ClearGuard® HD End Cap
NCT02593149 ·Status: COMPLETED ·Phase: NA
-
Comparison Study of Daily Ultrafiltration and Twice-weekly Hemodialysis
NCT00825318 ·Status: COMPLETED ·Phase: NA
-
A Clinical Study of the Safety and Efficacy of a Wearable Device (CLS UF) That Delivers Continuous Administration of Glucose to Recirculated Peritoneal Dialysis Fluid for the Purpose of Ultrafiltration in Patients With Congestive Heart Failure
NCT02772146 ·Status: TERMINATED ·Phase: NA
-
Comparing the Hemodiafiltration On-line and Conventional Hemodialysis in Terms of Cost-benefit
NCT02374372 ·Status: COMPLETED ·Phase: NA
-
Solute Removal With High Volume Hemodiafiltration Versus Long High Flux Hemodialysis
NCT01445366 ·Status: COMPLETED ·Phase: NA
-
Expanded Hemodialysis Versus High-Volume Online Hemodiafiltration for Uremic Toxin Removal
NCT07348536 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Ultrafiltration Profiling and Outcomes Among Individuals on Maintenance Hemodialysis
NCT03301740 ·Status: COMPLETED ·Phase: NA
-
Hemodynamic Responses in Hemodialysis Patients to Blood Flow Restriction Using Non-pneumatic Anti-shock Garments
NCT02915627 ·Status: COMPLETED ·Phase: NA
-
The Effect of On-line Hemodiafiltratrion on Nutritional Status and Body Composition
NCT03190629 ·Status: COMPLETED ·Phase: NA
-
Reduction of Oxalate and Inflammation by Hemodiafiltration vs. Hemodialysis
NCT02684656 ·Status: COMPLETED ·Phase: NA
-
Catheter Dysfunction Rate in Patients Undergoing Kidney Replacement Therapy. Evaluation of the Safety and Efficacy of Anti-reflux Valves Without Heparin Lock Solution
NCT06259266 ·Status: WITHDRAWN ·Phase: NA
-
Clotting With Different Dialyzer Membranes
NCT02546037 ·Status: COMPLETED
-
Impact of Different Dialysis on Sleep Apnea in Patients With Renal Failure
NCT00380848 ·Status: UNKNOWN ·Phase: NA
-
Water Soluble Vitamins and Trace Elements Loss in Hemodiafiltration Patients
NCT05099185 ·Status: COMPLETED
-
Effects of On-Line Hemodiafiltration(HDF) on Vascular Health in Chronic Hemodialysis Patients
NCT00532597 ·Status: UNKNOWN ·Phase: PHASE4
-
Increasing the Removal of Protein-Bound Solutes During Extended Hours Hemodialysis
NCT01892839 ·Status: UNKNOWN ·Phase: NA
-
Effect of a Pre Heparin Coated Dialysis Filter on Coagulation During Hemodialysis
NCT01388270 ·Status: COMPLETED ·Phase: PHASE4
-
An Extension to Assess the Effect of Expanded Dialysis on Patient Reported Symptoms Using LEVIL
NCT06032208 ·Status: RECRUITING ·Phase: NA
-
Sodium Chloride and Protein-Bound Toxin Removal in Hemodiafiltration
NCT01923961 ·Status: COMPLETED ·Phase: NA