Feasibility of an Analgesic Device Enabling Local Anesthetic Delivery and Neuromodulation After Shoulder/Foot Surgery

NCT06818708 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 20

Last updated 2025-11-18

Study results available
· View outcomes & findings →

Summary

Postoperative pain remains undertreated with inadequate analgesic options. Opioids have well-known limitations for both individuals and society; single-injection and continuous peripheral nerve blocks provide intense analgesia but are limited in duration to 24-72 hours; and current neuromodulation options-with a duration measured in weeks and not hours-are prohibitively expensive and require an additional procedure. One possible solution is a device currently under investigation to treat postoperative pain. The RELAY system (Gate Science, Moultonborough, New Hampshire) is comprised of a basic catheter-over-needle device to allow administration of a single-injection of local anesthetic via the needle (or catheter) followed by a perineural local anesthetic infusion via the remaining catheter (when desired). Subsequent to the local anesthetic administration, instead of removing the catheter as with all previous continuous peripheral nerve block equipment, electric current may be delivered via the same catheter and an integrated pulse generator for up to 28 days. This is potentially revolutionary because it would allow an anesthesiologist to deliver (1) a single-injection peripheral nerve block; (2) a continuous peripheral nerve block; and (3) neuromodulation using a single device that can theoretically be placed in the same amount of time required for a single-injection peripheral nerve block. Instead of providing fewer than 24 hours of postoperative analgesia, up to 28 days of pain control could be delivered without disruption of existing practice patterns. The ultimate objective of the proposed investigation is to prepare for a randomized clinical trial investigating the use of the RELAY device to provide postoperative analgesia.

This feasibility study will be a series of participants all receiving both local anesthetic and electric current via a single device (RELAY, Gate Science, Moultonborough, New Hampshire). The purpose will be to optimize the insertion approach and stimulation administration during the first 7 days following foot and shoulder surgery as well as training the clinical investigators.

Conditions

  • Rotator Cuff Injuries
  • Shoulder Disease
  • Hallux Valgus
  • Ankle Arthropathy

Interventions

DEVICE

Experimental Treatment

Percutaneous peripheral nerve stimulation with a frequency between 1-250 Hz, a pulse duration of 1-200 µs, and a current of 0.001-10 mA (1-10,000 µA). If the same pattern holds for the RELAY device as for previously tested peripheral nerve stimulators, we will maximize frequency, minimize pulse duration, and have participants adjust the amplitude, as needed.

Sponsors & Collaborators

Principal Investigators

  • Brian M Ilfeld, MD, Ms · University of California, San Diego

Study Design

Allocation
NA
Purpose
TREATMENT
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2025-03-20
Primary Completion
2025-06-12
Completion
2025-06-26
FDA Device
Yes

Countries

  • United States

Study Locations

More Related Trials

Entities

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT06818708 on ClinicalTrials.gov