Vapocoolant Spray's Role in Reducing Pain During Capillary Glucose Testing
NCT06789055 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 80
Last updated 2026-05-05
Summary
Capillary blood glucose measurement is a routine procedure in emergency departments, but it may cause pain and discomfort because it requires fingertip puncture. Vapocoolant spray is a rapid, noninvasive, and inexpensive method of topical analgesia that may reduce pain during minor procedures. However, its effectiveness during capillary blood glucose testing has not been sufficiently studied. This study aims to evaluate whether vapocoolant spray reduces pain during capillary blood glucose measurement compared with placebo in adult emergency department patients requiring at least two clinically indicated glucose measurements. In this randomized, placebo-controlled crossover trial, participants receive both vapocoolant spray and placebo in a randomized sequence before two separate capillary glucose measurements. Pain is assessed immediately after each procedure using a 100 mm Visual Analog Scale. The findings may help inform practical strategies to improve patient comfort during routine glucose testing in emergency care settings.
Conditions
- Visual Analog Pain Scale
Interventions
- OTHER
-
Vapocoolant Spray
Before the capillary blood glucose measurement, vapocoolant spray will be applied to the measurement site from a distance of 30 cm for 10 seconds. Following this, the area will be cleansed with an antimicrobial swab for 10 seconds using a circular motion, starting from the center and moving outward. Subsequently, the fingertip will be punctured with a lancet to obtain a blood sample. The first drop of blood will be wiped away with cotton, and the glucose measurement will be performed using the subsequent drop utilizing the Standard GlucoNavii GDH device. The patient will then be asked to assess their pain during the procedure using the Visual Analog Scale (VAS) for pain evaluation.
- OTHER
-
Placebo
Before the capillary blood glucose measurement, placebo will be applied to the measurement site from a distance of 30 cm for 10 seconds. Following this, the area will be cleansed with an antimicrobial swab for 10 seconds using a circular motion, starting from the center and moving outward. Subsequently, the fingertip will be punctured with a lancet to obtain a blood sample. The first drop of blood will be wiped away with cotton, and the glucose measurement will be performed using the subsequent drop utilizing the Standard GlucoNavii GDH device. The patient will then be asked to assess their pain during the procedure using the Visual Analog Scale (VAS) for pain evaluation.
Sponsors & Collaborators
-
Abant Izzet Baysal University
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- SUPPORTIVE_CARE
- Masking
- QUADRUPLE
- Model
- CROSSOVER
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2025-03-10
- Primary Completion
- 2025-03-14
- Completion
- 2025-03-14
Countries
- Turkey (Türkiye)
Study Locations
More Related Trials
-
Epidermal Adhesive Sensors to Enhance Continuous Glucose Measurement in Patients With Diabetes: The EASE Study
NCT04088201 ·Status: UNKNOWN ·Phase: NA
-
Validation of a 13C Glucose Breath Test Compared With the Euglycaemic Clamp Test
NCT04623320 ·Status: UNKNOWN
-
A Trial Investigating the Accuracy and Precision of the BGStar® and iBGStar® Blood Glucose Meter in Subjects With Type 1 Diabetes
NCT01730885 ·Status: COMPLETED ·Phase: PHASE4
-
Afamin in Gestational Diabetes Mellitus
NCT04054843 ·Status: COMPLETED
-
Pregnancy on Oral Glucose Tolerance Test Implementation Status, Knowledge, and Anxiety Level
NCT05686694 ·Status: COMPLETED ·Phase: NA
-
Use of Continuous Glucose Monitoring Devices Among People Living With Type 1 Diabetes in Kenya.
NCT05944731 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Effect of Short Peripheral Electrical Stimulation (PES) on Blood Glucose
NCT02727790 ·Status: COMPLETED ·Phase: NA
-
Effects of Novel Flash Glucose Monitoring System on Glycemic Control in Adult Patients With Type 1 Diabetes Mellitus
NCT03522870 ·Status: COMPLETED ·Phase: NA
-
Continuous Glucose Monitor Use in Pregnancy
NCT05317585 ·Status: RECRUITING ·Phase: NA
-
Performance and Safety Evaluation of a Novel Non-invasive Glucose Monitoring Device and Evaluation of the Instructions for Use
NCT04033042 ·Status: COMPLETED ·Phase: NA
-
Evaluation of a Flash Glucose Monitoring System in Ambulatory Patients With Type 1 Diabetes
NCT02677454 ·Status: COMPLETED ·Phase: NA
-
Accuracy, Satisfaction and Usability of a FGM System Among Children and Adolescents Attending a Diabetes Summer Camp
NCT03368586 ·Status: COMPLETED
-
Strawberry Candy Twists as an Alternative Screen for Gestational Diabetes: A Prospective Trial
NCT02610179 ·Status: RECRUITING ·Phase: NA
-
Diabetes in African Youth
NCT05454176 ·Status: RECRUITING ·Phase: PHASE4
-
Performance of an Investigational Blood Glucose Monitoring System
NCT01824355 ·Status: COMPLETED ·Phase: NA
-
Evaluating Use of Continuous Glucose Monitors in a Short-term 2x2-Crossover Study
NCT04424888 ·Status: COMPLETED ·Phase: NA
-
STUDY OF GLUCOSE IN DIALYSIS WATER WITH REGARD TO BLOOD PRESSURE AND QUALITY OF LIFE
NCT00278057 ·Status: COMPLETED ·Phase: PHASE4
-
Effect of Continuous Glucose Monitoring on Course of Glucose in Type 1 Diabetes
NCT00467688 ·Status: COMPLETED ·Phase: NA
-
A Trial Comparing Continuous Glucose Monitoring With and Without Routine Blood Glucose Monitoring in Adults With Type 1 Diabetes
NCT02258373 ·Status: COMPLETED ·Phase: NA
-
Effects of Neuromuscular Electrical Stimulation on Glucose Variability in Patients With Type 2 Diabetes
NCT03256747 ·Status: COMPLETED ·Phase: NA
-
Flash Glucose Monitoring in Gestational Diabetes Mellitus: Study Protocol for a Randomized Controlled Trial
NCT04422821 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Accuracy and Safety of A Novel Real-Time Continuous Glucose Monitoring System
NCT07092761 ·Status: RECRUITING ·Phase: NA
-
Evaluating System Accuracy of Blood Glucose Monitoring Systems for Self-testing in Managing Diabetes Mellitus
NCT01729546 ·Status: COMPLETED ·Phase: NA
-
System Accuracy and User Performance of Blood Glucose Monitoring Systems for Self-Testing in Managing Diabetes Mellitus
NCT02290067 ·Status: COMPLETED ·Phase: NA
-
Tolerability, Acceptance, and Utility of Intermittent CGM Use in Youth With Prediabetes
NCT05505565 ·Status: COMPLETED ·Phase: NA