Transcatheter Tricuspid Valve Replacement Using the Lux-Valve Plus System
NCT06714500 · Status: ENROLLING_BY_INVITATION · Phase: NA · Type: INTERVENTIONAL · Enrollment: 20
Last updated 2024-12-03
Summary
Tricuspid regurgitation (TR) is a common disease, and the tricuspid valve (TV) is no longer a "forgotten valve". Open heart surgery for isolated TR is uncommonly performed due to high operative risk (8-10% mortality). However, TR is associated with increased morbidity and mortality. There exists an unmet clinical need for less invasive intervention to treat TR. Transcatheter edge to edge repair (TEER) is a technique that is shown to be safe and effective in TR reduction and is associated with significant symptom improvement. However, a significant portion of TV anatomy are not suitable to be treated with TEER (e.g. coaptation gap \>10mm). A wide variety of technologies has been developed in recent years. Transcatheter tricuspid valve replacement (TTVR) is one of the more promising option for tricuspid regurgitation (TR) patients at high risk for surgery. A previous study reported that transcatheter tricuspid devices, which were employed with the radial force between the device and tricuspid annulus, were radial force-dependent. However, this radial force for valve fixation may cause complications, such as conduction block and right coronary artery impingement. The LuX-Valve (Jenscare Biotechnology) is a radial force-independent orthotopic TTVR device. The feasibility and efficacy of this device have been reported by several studies. However, this valve was implanted through right atrial access, where a small incision of the right chest and right atrium is needed. The LuX-Valve Plus valve replacement system is the second-generation version of the LuX-Valve and can be implanted through the jugular vein. The first-in-human implantation was recently performed. The study aims to assess the feasibility, safety and efficacy outcome of the Lux Valve Plus system in a cohort of otherwise no surgical option patients with severe symptomatic tricuspid regurgitation despite optimal medical therapy.
Conditions
- Tricuspid Regurgitation
Interventions
- DEVICE
-
LuxValve PLlus
The LuX-Valve (Jenscare Biotechnology) is a radial force-independent orthotopic TTVR device. The feasibility and efficacy of this device have been reported by several studies (11-13). However, this valve was implanted through right atrial access, where a small incision of the right chest and right atrium is needed. The LuX-Valve Plus valve replacement system is the second-generation version of the LuX-Valve and can be implanted through the jugular vein.
Sponsors & Collaborators
-
Prince of Wales Hospital, Shatin, Hong Kong
lead OTHER
Principal Investigators
-
Kent So, PI · Chinese University of Hong Kong
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 50 Years
- Max Age
- 90 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2023-09-18
- Primary Completion
- 2025-12-31
- Completion
- 2026-06-30
Countries
- Hong Kong
Study Locations
More Related Trials
-
International Multisite Transcatheter Tricuspid Valve Therapies Registry
NCT03416166 ·Status: RECRUITING
-
The Comparison of Tricuspid Replacement and Repair in Patients With Combined Heart Valve Disease
NCT01246141 ·Status: COMPLETED
-
Comparison of a Single Versus Double Perclose Technique for TAVR
NCT06173115 ·Status: RECRUITING ·Phase: NA
-
Feasibility Study of the DragonFly-T System for Severe Tricuspid Regurgitation
NCT05671640 ·Status: UNKNOWN ·Phase: NA
-
Application of Comprehensive Non-invasive Assessment To Phenotype Tricuspid Regurgitation
NCT07042360 ·Status: RECRUITING
-
Treatment of Severe Secondary TRIcuspid Regurgitation in Patients With Advance Heart Failure With CAval Vein Implantation of the Edwards Sapien XT VALve (TRICAVAL)
NCT02387697 ·Status: TERMINATED ·Phase: PHASE2/PHASE3
-
Minimally Invasive Tricuspid Surgery vs Medical Treatment for Severe TR
NCT04339192 ·Status: UNKNOWN ·Phase: NA
-
Transcatheter Aortic Valve Replacement for Pure Severe Aortic Valve Regurgitation
NCT06381271 ·Status: RECRUITING
-
THE TRAVEL TRIAL: Transcatheter Right Atrial-ventricular Valve rEplacement With LuX-Valve
NCT04436653 ·Status: RECRUITING ·Phase: NA
-
Investigation of a Transcatheter Tricuspid Valved Stent Graft in Patients With Carcinoid Heart Disease
NCT05064514 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
The Asia-Pacific Mitral & Tricuspid Valve-in-Valve/Valve-in-Ring Registry
NCT07296016 ·Status: NOT_YET_RECRUITING
-
TARGET 2.0 Study: Safety and Performance of the Cardiovalve TR Replacement System
NCT07334691 ·Status: RECRUITING ·Phase: NA
-
Assessing the Right Heart Remodeling After Transcatheter Tricuspid Edge-to-edge Repair
NCT06309524 ·Status: RECRUITING
-
Study of the Clinical Impact of Surgical Correction of Tricuspid Insufficiency in Implantable LVAD Patients
NCT02537769 ·Status: RECRUITING ·Phase: NA
-
Transcatheter Valve Implantation in Patients With Dysfunctional Left and Right Sided Heart Valves
NCT02119442 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Tricuspid Valve Percutaneous Repair System in the Treatment of Severe Secondary Tricuspid Disorders
NCT04646811 ·Status: COMPLETED ·Phase: NA
-
The TRICURE EU Pivotal Study
NCT06581471 ·Status: RECRUITING ·Phase: NA
-
Cardiac Implantable Electronic Device- Induced Remodelling of Tricuspid Valve and Right Chambers
NCT06914570 ·Status: RECRUITING
-
Prospective Evaluation of Programmed Ventricular Stimulation Before Pulmonary Valve Replacement in Patients With Tetralogy of Fallot
NCT04205461 ·Status: UNKNOWN
-
Percutaneous Edge To Edge Repair for the Treatment of Severe Tricuspid Valve Regurgitation in High-surgical Risk Patients With Systemic Right Ventricle : a Multicentric French Cohort (PETER-TRESRIV)
NCT05052177 ·Status: UNKNOWN
-
The Safety and Efficacy of Tolvaptan for Patients With Tricuspid Regurgitation and Right Heart Failure After Left Heart Valves Replacement
NCT02644616 ·Status: COMPLETED ·Phase: PHASE4
-
Portico TAVI Implant With Transfemoral Delivery System
NCT01493284 ·Status: COMPLETED ·Phase: NA
-
German Registry for Transcatheter Tricuspid Valve Interventions
NCT04653428 ·Status: RECRUITING
-
Electroanatomic Interactions Between Transcatheter Pulmonary Valve Prostheses and Anatomic Isthmuses in Repaired Tetralogy of Fallot
NCT05236153 ·Status: UNKNOWN ·Phase: NA
-
TARGET Study: Safety and Performance of the Cardiovalve TR Replacement System
NCT05486832 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA