A Study to Evaluate the Safety and Performance of LuX-Valve Plus System for Tricuspid Replacement
NCT05436028 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 161
Last updated 2025-05-21
Summary
This is a prospective, single-arm, multi-center trial to evaluate the LuX-Valve Plus system for treating symptomatic at least severe TR in patients who are deemed high risk for tricuspid surgery.
Treatment with the LuX-Valve Plus system may enable patients with tricuspid regurgitation to have a complete tricuspid valve replacement with a minimally invasive approach.
Up to 150 subjects will be implanted at up to 24 institutions worldwide. No single institution will be allowed to register more than 25% of total subjects. There is no minimum number of subjects to be registered at any site.
Up to3 per site, may be implanted by operators without prior experience using the LuX-Valve Plus device to gain hands-on experience.Each site has a maximum of 3 roll-in cases. The data of roll-in subjects will not count towards the overall enrollment cap. Safety and performance results of roll-in subjects will be analyzed in subgroups.
All subjects will be evaluated at baseline, procedure, discharge, 30 days, 6 months, 1 year, 2 years, 3 years, 4 years, and 5 years post-procedure.
Conditions
- Tricuspid Regurgitation
Interventions
- DEVICE
-
Transcatheter Tricuspid Valve Intervention
Due to unsustainable effect of medical therapy and high risks of surgical treatment, transcatheter tricuspid valve intervention (TTVI) has been a major field of study in the world in the last 10 years. TTVI could potentially reduce TR with lower periprocedural risk and improve the patient's clinical status and prognosis. Per the ESC guidelines for surgical and interventional treatment of tricuspid regurgitation (2021 ESC/EACTS Guidelines for the Management of Valvular Heart Disease), Transcatheter intervention for symptomatic secondary severe TR may be considered in inoperable patients at a Heart Valve Centre with expertise in the treatment of tricuspid valve disease (Class IIb). Transcatheter tricuspid treatment options can be divided into categories based on their mechanism of action: coaptation enhancement (edge-to-edge repair and spacer device), annuloplasty devices, caval valve implantation and valve replacement.
Sponsors & Collaborators
-
Jenscare Scientific
lead INDUSTRY
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 50 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2023-05-23
- Primary Completion
- 2024-11-30
- Completion
- 2024-11-30
Countries
- France
Study Locations
More Related Trials
-
Safety and Feasibility of the Transcatheter Tricuspid Valve Repair System (Trialign)
NCT04936802 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of Tricuspid Valve Percutaneous Repair System in the Treatment of Severe Secondary Tricuspid Disorders
NCT04646811 ·Status: COMPLETED ·Phase: NA
-
Transcatheter Aortic Valve Implantation Versus Standard Surgical Aortic Valve Replacement
NCT05261204 ·Status: ENROLLING_BY_INVITATION
-
Transcatheter Aortic Valve Replacement for Pure Severe Aortic Valve Regurgitation
NCT06381271 ·Status: RECRUITING
-
Safety and Effectiveness Study of DragonFly-T System for Severe Tricuspid Regurgitation
NCT05556460 ·Status: RECRUITING ·Phase: NA
-
Evaluate the Transcatheter Artificial Aortic Valve and Transcatheter Artificial Heart Values Delivery System
NCT03788590 ·Status: UNKNOWN ·Phase: NA
-
Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients
NCT02701283 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Feasibility Study of the DragonFly-T System for Severe Tricuspid Regurgitation
NCT05671640 ·Status: UNKNOWN ·Phase: NA
-
Bicuspid Aortic Valve Replacement: Evaluation of Transcatheter Versus Surgery-Pilot Trial
NCT06817148 ·Status: RECRUITING ·Phase: NA
-
J-Valve TF Early Feasibility Study
NCT06034028 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Comparison of a Single Versus Double Perclose Technique for TAVR
NCT06173115 ·Status: RECRUITING ·Phase: NA
-
TARGET Study: Safety and Performance of the Cardiovalve TR Replacement System
NCT05486832 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Prospective Evaluation of Programmed Ventricular Stimulation Before Pulmonary Valve Replacement in Patients With Tetralogy of Fallot
NCT04205461 ·Status: UNKNOWN
-
Prizvalve Transcatheter Aortic Valve in Failing Bioprosthetic Valves
NCT07122050 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
TARGET 2.0 Study: Safety and Performance of the Cardiovalve TR Replacement System
NCT07334691 ·Status: RECRUITING ·Phase: NA
-
TAVR for Aortic Valve Disease
NCT05439863 ·Status: RECRUITING
-
TAVIS Registry - Trilogy Heart Valve System for Management of Patients With Aortic Valve Disease
NCT05536310 ·Status: NOT_YET_RECRUITING
-
Minimally Invasive Tricuspid Surgery vs Medical Treatment for Severe TR
NCT04339192 ·Status: UNKNOWN ·Phase: NA
-
Treatment of Severe Secondary TRIcuspid Regurgitation in Patients With Advance Heart Failure With CAval Vein Implantation of the Edwards Sapien XT VALve (TRICAVAL)
NCT02387697 ·Status: TERMINATED ·Phase: PHASE2/PHASE3
-
Retrospective Prospective Multicentric Clinical Follow up of Patients After Being Treated With TricValve®
NCT05114850 ·Status: RECRUITING
-
Expanded Study of the HighLife 28mm Trans-septal Trans-catheter Mitral Valve in Patients With Moderate-severe or Severe Mitral Regurgitation and at High Surgical Risk
NCT04029363 ·Status: RECRUITING ·Phase: NA
-
The JenaValve ALIGN-AR LVAD Registry
NCT06594705 ·Status: RECRUITING ·Phase: NA
-
Hemodynamic Matched Comparison of the Balloon-Expandable Transcatheter Heart Valves Myval and Sapien-3 for the Treatment of Aortic Stenosis
NCT04548726 ·Status: COMPLETED
-
Transcatheter Aortic Valve Replacement to UNload the Left Ventricle in Patients With ADvanced Heart Failure (TAVR UNLOAD)
NCT02661451 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
The Safety and Effectiveness of Transcatheter Aortic Valve Raplacemet in Intermediate Risk Patients With Bicuspid Aortic Stenosis
NCT03163329 ·Status: UNKNOWN ·Phase: PHASE2