Clinical Study to Evaluate the Impact of the Accu-Chek SmartGuide CGM Solution on the Mean Change in Time in Range Compared With Self-Monitoring of Blood Glucose in Participants With Type 1 and Type 2 Diabetes Mellitus
NCT06704672 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 270
Last updated 2026-05-14
Summary
This is an open label, two-arm, randomized multi-center clinical device study in adult subjects with Type 1 diabetes (T1D) or insulin-dependent Type 2 diabetes (T2D) on a multiple daily injection (MDI) regime.
The goal of the study is to investigate the impact of the Accu-Chek SmartGuide CGM solution on the change in overall time in range (TIR) of blood glucose concentrations of 70-180 mg/dl compared with that using self-monitoring of blood glucose (SMBG).
Conditions
- Type 1 Diabetes Mellitus
- Type 2 Diabetes Mellitus
Interventions
- DEVICE
-
Accu-Chek SmartGuide CGM Solution
The Accu-Chek SmartGuide CGM solution is used for real-time continuous glucose monitoring (CGM) in the interstitial fluid. It consists of the Accu-Chek SmartGuide device and two smartphone applications (apps): the Accu-Chek SmartGuide app and the Accu-Chek SmartGuide Predict app. The Accu-Chek SmartGuide device contains a CGM sensor pre-assembled in a sensor applicator. It has connectivity to the smartphone that is running the Accu-Chek apps. The Accu-Chek SmartGuide app is the primary display of the real-time glucose values. The Accu-Chek SmartGuide Predict app is an information management tool that further visualizes and analyzes diabetes data from the Accu-Chek SmartGuide device.
- DEVICE
-
Accu-Chek SmartGuide Sensor and Blinded Apps
The participants in the SMBG control group will wear a SmartGuide sensor with blinded SmartGuide apps intermittently, i.e., during the assessment periods. It is not possible to read out the glucose data from the blinded app, hence neither the SmartGuide app nor the SmartGuide Predict functionalities can be accessed by the participants in this group.
- DEVICE
-
SMBG Device
With the SmartGuide apps in blinded mode, participants in the SMBG control group will continue using their own SMBG device or they may use the Accu-Chek Instant meter that will be provided for calibration of the SmartGuide device.
Sponsors & Collaborators
-
Roche Diabetes Care
collaborator INDUSTRY - lead INDUSTRY
Principal Investigators
-
Clinical Trials · Hoffmann-La Roche
Study Design
- Allocation
- RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2025-04-14
- Primary Completion
- 2026-06-15
- Completion
- 2026-12-31
Countries
- Poland
- Turkey (Türkiye)
Study Locations
More Related Trials
-
Effect of Switching From Intermittently Scanned to Real-time Continuous Glucose Monitoring on Diabetes Management in Adults With Type 2 Diabetes (Switch CGM T2D)
NCT06805786 ·Status: RECRUITING
-
Continuous Glucose Monitoring & Management In Type 2 Diabetes (T2D)
NCT03620357 ·Status: COMPLETED ·Phase: NA
-
To Evaluate the Change in Glucose Parameters in Adult Patients With Type 1 or Type 2 Diabetes From Europe Using the iCan o3 CGM System for 60 Days Period
NCT06904846 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Accu-Chek missiOn: SMBG in Patients With diAbetes on inSulin Study (COMPASS) - Multiple Center, Open, and Non-randomized Study
NCT01130480 ·Status: COMPLETED ·Phase: NA
-
Comparison of Real-tiMe ContInuous gLucosE moNitoriNg With Self-monitorIng of Blood Glucose in Young AduLts With Type 1 diabeteS
NCT03445377 ·Status: COMPLETED ·Phase: NA
-
Evaluating System Accuracy of Blood Glucose Monitoring Systems for Self-testing in Managing Diabetes Mellitus
NCT01729546 ·Status: COMPLETED ·Phase: NA
-
Comparison of Real-time CGMS With Intermittently-scanned CGMS in Adolescents and Adults With Type 1 Diabetes Mellitus
NCT05928260 ·Status: UNKNOWN ·Phase: NA
-
Develop Novel Methods to Display, Report and Analyze CGM Data for Clinical Decision-Making in People With Diabetes
NCT00465881 ·Status: COMPLETED
-
Steno2tech - Continuous Glucose Monitoring and Type 2 Diabetes.
NCT04331444 ·Status: COMPLETED ·Phase: NA
-
Effect on HbA1c of the Initiation of CGM in Adults With Type 2 Diabetes Treated With Basal Insulin in Finland
NCT06268821 ·Status: TERMINATED ·Phase: NA
-
Accuracy of Two CGM Systems Tested Simultaneously in Ambulatory Patients With Type 1 Diabetes
NCT02159638 ·Status: COMPLETED ·Phase: NA
-
System Accuracy Evaluation of 6 CE-marked Blood Glucose Monitoring System Following ISO 15197:2013
NCT02531386 ·Status: COMPLETED ·Phase: NA
-
Effects of Novel Flash Glucose Monitoring System on Glycemic Control in Adult Patients With Type 1 Diabetes Mellitus
NCT03522870 ·Status: COMPLETED ·Phase: NA
-
User Performance Evaluation of Contour Plus, Accu-Chek Active, Accu-Chek Performa and OneTouch Select Simple Blood Glucose Monitoring Systems Following ISO 15197:2013
NCT02461394 ·Status: COMPLETED ·Phase: NA
-
Secondary Care - Continuous Glucose Monitoring
NCT03487887 ·Status: COMPLETED
-
Continuous Glucose Monitoring Self-Monitored Blood Glucose Type 2 Therapy Matrix Definition
NCT01390610 ·Status: COMPLETED
-
Performance and Safety Evaluation of a Novel Non-invasive Glucose Monitoring Device and Evaluation of the Instructions for Use
NCT04033042 ·Status: COMPLETED ·Phase: NA
-
To Evaluate the Efficacy and Safety of Multi-parameter Non-Invasive Glucose Sensors for for Blood Glucose Measurement
NCT06017349 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Accuracy and Safety of A Novel Real-Time Continuous Glucose Monitoring System
NCT07092761 ·Status: RECRUITING ·Phase: NA
-
Self-monitoring of Blood Glucose in Insulin-treated Patients With Type 2 Diabetes
NCT01460459 ·Status: UNKNOWN ·Phase: NA
-
An Evaluation of a Novel Glucose Sensing Technology in Type 2 Diabetes
NCT02082184 ·Status: COMPLETED ·Phase: NA
-
Successfully Achieving and Maintaining Euglycemia During Pregnancy for Type 2 Diabetes Through Technology and Coaching
NCT05662462 ·Status: RECRUITING ·Phase: NA
-
Self-Monitoring of Blood Glucose Study#1: The Ability of People With Diabetes to Use OneTouch(R) Ultrasmart(tm)
NCT00333853 ·Status: COMPLETED ·Phase: NA
-
Type 2 Diabetes (T2D) Basal Insulin Users: The Mobile Study (MOBILE)
NCT03566693 ·Status: COMPLETED ·Phase: NA
-
A Proof of Concept (PoC), Randomized, Controlled Study to Validate the Algorithm and Evaluate the Accuracy, Safety and Pain Level of the Smartest-AE in Comparison to Self-measure Blood Glucose Levels
NCT06587087 ·Status: NOT_YET_RECRUITING ·Phase: NA