The SEQUENCE Trial: Evaluating Diagnostic Yield of Robotic-assisted Bronchoscopy When Staging EBUS is Performed First or Second in the Same Procedure
NCT06676956 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 320
Last updated 2024-11-06
Summary
Robotic-assisted bronchoscopy (RaB) has afforded proceduralists the ability to accurately reach the periphery of the lung for biopsy of pulmonary nodules1. This has paved the way for patients to undergo both biopsy of a peripheral nodule and a staging linear endobronchial ultrasound (EBUS) in the same anesthesia event, promoting quicker throughput from discovery of a lesion to guideline-adherent treatment2. Further, introduction and mainstream utilization of cone-beam CT (CBCT) has provided the bronchoscopist the ability to refine needle position with tool-in-lesion confirmation3. While there are no randomized clinical trials promoting efficacy of RaB and CBCT in comparison with other bronchoscopic methods, in single center retrospective studies, diagnostic yield has consistently proven to be in the 70-85% range, superior to prior technologies4-6.
One of the limitations of utilization of RaB and CBCT is the detrimental effect that atelectasis plays in the bronchoscopy procedure. This can lead to false positive radial EBUS (rEBUS) signals and non-diagnostic procedures7. This incidence of atelectasis has been evaluated prospectively, using a protocol featuring 8-10 cmH2O of PEEP and limiting hyperoxia8, and results suggest this ventilator strategy does an adequate job preventing intraprocedural lung collapse. However, this study only evaluated incidence of atelectasis and did not elaborate on its impact on diagnostic yield.
Further unknown is the optimal sequence of performance of RaB and a staging linear EBUS in patients with a radiographically normal mediastinum. Starting with either the RaB or Linear EBUS both have their pros and cons. The benefit to performance of a linear EBUS first is the potential to obviate the need for peripheral nodule biopsy by obtaining rapid, on-site pathologic feedback of occult nodal disease, reducing some of the risk of the procedure (i.e. bleeding and pneumothorax).6 Conversely, the pitfalls to performing linear EBUS first is the possible contribution of atelectasis resultant of the increased time from intubation to peripheral nodule biopsy, blood in the airway causing bronchospasm, and resorption atelectasis from hyperoxia9. There are no prospective data evaluating this in a randomized fashion, but one Monte Carlo simulation (with assumption of diagnostic yield from navigational bronchoscopy of 70% when performed first and 60% when performed second) suggested a higher diagnostic yield and less need for repeat procedure in the navigation first group, despite a 10% assumption of occult nodal disease10.
As outlined in the specific aims above, the overarching goals of this study are to assess in a multicenter, randomized clinical trial performed by members of the Interventional Pulmonary Outcomes Group (IPOG), whether sequence of staging EBUS plays a role in diagnostic yield, incidence of atelectasis, and safety outcomes in patients undergoing RaB.
Conditions
- Pulmonary Nodules
Interventions
- PROCEDURE
-
Order of bronchoscopy procedures for peripheral nodule biopsy
Patient scheduled to undergo peripheral nodule biopsy of the lung under bronchoscopy typically get both a nodule biopsy as well as a linear EBUS of the lymph nodes to assess for any disease spread. This procedure will randomize patients to either getting the peripheral nodule first or linear EBUS of the lymph nodes first and assess overall diagnostic yield as the primary outcome.
Sponsors & Collaborators
- lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2024-11-10
- Primary Completion
- 2026-11-01
- Completion
- 2027-04-01
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Feasibility of a Minimally Invasive Thoracoscopic Ultrasound for Localization of Pulmonary Nodules
NCT02665078 ·Status: COMPLETED
-
Confocal Laser Endomicroscopy Guided Cryobiopsy in the Diagnosis of Interstitial Lung Disease
NCT06741826 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
EBUS-TBNA vs Transbronchial Mediastinal Cryobiopsy for Adequacy of Next Generation Sequencing
NCT06105801 ·Status: RECRUITING ·Phase: PHASE4
-
Preoperative Lymph Node Staging With EBUS-TBNA in Clinical N0 Non Small-cell Lung Cancer
NCT04828850 ·Status: UNKNOWN ·Phase: NA
-
Technique for Localization of Pulmonary Nodules Using Spy Thoracoscope System
NCT02090660 ·Status: COMPLETED ·Phase: PHASE2
-
Radial-Probe Endobronchial Ultrasound in Detecting Atelectasis in Patients Undergoing Peripheral Bronchoscopy
NCT03523689 ·Status: COMPLETED
-
ROSE for Improved Molecular Marker Testing Via EBUS
NCT04945317 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
A Trial of Radial EBUS Versus VBN for the Peripheral Pulmonary Lesions
NCT05739695 ·Status: RECRUITING ·Phase: NA
-
Evaluate the Diagnostic Value of Puncture Biopsy for PPL Under the Guidance of Navigation and Radial EBUS: a Real-World Study
NCT04692038 ·Status: UNKNOWN
-
Predictive Diagnostic Criteria for Diagnosis of Transbronchial Biopsies, Echo-guided by Mini-probe in Peripheral Lung Lesions
NCT03132870 ·Status: COMPLETED
-
Clinical Impact of EUS in Staging NSCLC
NCT00577746 ·Status: COMPLETED
-
The Analysis of the EBUS Scope as a Hybrid Bronchoscope
NCT02360306 ·Status: COMPLETED ·Phase: NA
-
iNod™ Ultrasound-Guided Needle Biopsy System Study
NCT05804435 ·Status: WITHDRAWN ·Phase: NA
-
The Diagnostic Yield and Safety of Transbronchial Cryobiopsy in The Pulmonary Periphral Nodule
NCT04661956 ·Status: UNKNOWN ·Phase: NA
-
Bronchoscopic Navigation Robot-guided Dye Marking-assisted Thoracoscopic Pulmonary Nodule Resection
NCT06821451 ·Status: RECRUITING ·Phase: NA
-
Endobronchial Ultrasound Guided Transbronchial Needle Aspiration (EBUS-TBNA) for Mediastinal Re-staging of Non-small Cell Lung Cancer(NSCLC)
NCT00859742 ·Status: WITHDRAWN ·Phase: NA
-
Diagnostic Value of EBUS-Guided Transbronchial Mediastinal Cryobiopsy Versus Conventional Bronchoscopic Approaches for Stage I/II Sarcoidosis
NCT07246876 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
EBUS TBNA After PET/CT in Diagnosing Patients With Stage I-IIA Non-small Cell Lung Cancer Evaluated for Stereotactic Body Radiation Therapy
NCT02719847 ·Status: COMPLETED
-
AI-EBUS-Elastography for LN Staging
NCT04816981 ·Status: COMPLETED ·Phase: NA
-
Endobronchial Ultrasound- Transbronchial Needle Aspiration (EBUS-TBNA) Versus Mediastinoscopy for Mediastinal Lymph Node Staging of Non-small Cell Lung Cancer (NSCLC)
NCT01079520 ·Status: COMPLETED ·Phase: NA
-
The Comparison of Navigational Bronchoscopic and CT-Guided Preoperative Markings in Minimally Invasive Thoracic Surgery
NCT06957600 ·Status: COMPLETED ·Phase: NA
-
Endobronchial Ultrasound Needle Aspiration With and Without Suction
NCT05110950 ·Status: UNKNOWN ·Phase: NA
-
A Comparison Between EBUS-GS and CT-guided Lung Biopsy in Diagnosis of Peripheral Pulmonary Lesions.
NCT02740400 ·Status: UNKNOWN ·Phase: NA
-
Value of Rapid on Site Evaluation During EBUS-guided TBNA in the Diagnosis of Mediastinal Lesions
NCT02690610 ·Status: COMPLETED ·Phase: NA
-
EUS-FNA in the Pre-Operative Evaluation of Patients With Lung Cancer
NCT00119470 ·Status: COMPLETED ·Phase: PHASE2