A Prospective Observational Study of Transcranial Doppler Ultrasound in the Assessment of Cerebral Blood Flow After Polyetheretherketone Cranioplasty
NCT06642532 · Status: RECRUITING · Type: OBSERVATIONAL · Enrollment: 10
Last updated 2024-11-15
Summary
Polyetheretherketone has become one of the most important material choices for cranioplasty surgery. It has been shown that conventional ultrasound can be performed through the polyetheretherketone material for the examination of brain tissue and ventricular morphology. Transcranial doppler ultrasound can obtain good images of cerebral hemodynamic parameters in patients through polyetheretherketone-covered temporal window. This trial is a clinical prospective observational study in which cases treated with polyetheretherketone cranioplasty, and transcranial doppler ultrasonography is performed preoperatively and 10 days postoperatively, and data were collected mainly including bilateral hemodynamic parameters of middle cerebral artery(MCA), terminal internal carotid artery(TICA), (anterior communicating artery)ACA, and posterior cerebral artery(PCA) (Vs, Vd, Vm, PI index, RI index) from temporal window.
Conditions
- Cranial Defect
- TCD
Interventions
- DEVICE
-
TCD group
Transcranial Doppler ultrasound to examine bilateral hemodynamic parameters of middle cerebral artery(MCA), terminal internal carotid artery(TICA), (anterior communicating artery)ACA, and posterior cerebral artery(PCA) (Vs, Vd, Vm, PI index, RI index) from temporal window
Sponsors & Collaborators
-
RenJi Hospital
lead OTHER
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2024-06-01
- Primary Completion
- 2024-12-31
- Completion
- 2024-12-31
Countries
- China
Study Locations
More Related Trials
-
A Comparison Between Two Techniques for Performing Decompressive Craniectomy
NCT02594137 ·Status: COMPLETED ·Phase: NA
-
Accuracy of TCD Monitoring in Predicting Cerebral Hyperperfusion Syndrome After Carotid Endarterectomy
NCT01799070 ·Status: UNKNOWN
-
The Safety and Efficacy of Peri-procedure Blood Pressure Management of Revascularization
NCT03256513 ·Status: UNKNOWN ·Phase: NA
-
Parameters of Cerebral Perfusion
NCT02806492 ·Status: COMPLETED ·Phase: NA
-
A Prospective Randomized Controlled Trial on the Use of Cerebral Oximetry in Adult Chinese Patients Undergoing Liver Transplantation
NCT04122027 ·Status: UNKNOWN ·Phase: NA
-
Carotid Artery Corrected Flow Time Measured by Ultrasonography as a Predictor of Hypotension After Induction of General Anesthesia
NCT02891772 ·Status: WITHDRAWN
-
Postoperative Temperature Monitoring In Brain Trauma
NCT03068143 ·Status: UNKNOWN
-
Non-invasive Monitor in Endoscopic Invasive Procedure
NCT03292627 ·Status: COMPLETED
-
Corrected Flow Time in the Carotid Artery as a Predictor of Fluid Responsiveness in Mechanically Ventilated Patients With Low Tidal Volume in the Intensive Care Unit
NCT04139031 ·Status: COMPLETED
-
Clinical Study of Combined Carotid Artery With Inferior Vena Cava Ultrasonography to Predict Hypotension After Induction of General Anesthesia
NCT05472025 ·Status: UNKNOWN
-
Ability of Changes in End Tidal Carbon Dioxide to Assess the Stroke Volume Effects of a Volume Expansion of 250ml of Crystalloid in the Operating Room
NCT03635307 ·Status: COMPLETED
-
Ultrasound Assessment of Changes in the Diameter of the Common Carotid Artery After Increasing the Preload of the Heart
NCT03412422 ·Status: WITHDRAWN
-
Carotid Artery Corrected Flow Time as a Predictor of Hypotension After Induction of General Anesthesia in Elderly Patients
NCT05628051 ·Status: COMPLETED
-
Cerebral Blood Flow Velocity Changes During Laparoscopic Surgery
NCT04291326 ·Status: UNKNOWN
-
Middle Cerebral Artery Velocity and Oxygen Saturation of the Brain During Carotid Endarterectomy
NCT02665104 ·Status: UNKNOWN
-
Evaluation of Corrected Carotid Artery Flow Time as a Predictor of Fluid Responsiveness in Spontaneous Breathing Patients
NCT02843477 ·Status: COMPLETED
-
Use of Point-of-care Ultrasound in High Risk Surgical Patients
NCT03123536 ·Status: UNKNOWN
-
An Gong Niuhuang Wan Promotes the Postoperative Neurological Function Recovery of Patients With Traumatic Brain Injury
NCT07074938 ·Status: RECRUITING ·Phase: NA
-
Transpharyngeal Doppler Sonography for Cerebral Perfusion Monitoring
NCT03494413 ·Status: COMPLETED ·Phase: NA
-
Cerebral Perfusion Monitoring With Transpharyngeal Ultrasonography
NCT01828411 ·Status: TERMINATED
-
Efficacy of Lung and Inferior Vena Cava Sonography for Fluid Optimization
NCT05400343 ·Status: UNKNOWN ·Phase: NA
-
Autoregulation Assessment During Liver Transplantation
NCT01425385 ·Status: COMPLETED
-
Assessment of Ultrasonographic Measurement of Inferior Vena Cava Collapsibility Index in Prediction of Hypotension Associated With Tourniquet Release in Total Knee Replacement Surgeries Under Spinal Anesthesia
NCT05076929 ·Status: COMPLETED
-
Confirming Permanent Lack of Blood Flow to the Brain During A-NRP DCC Organ Transplant
NCT05884736 ·Status: RECRUITING
-
Consistency of Carotid Doppler Blood Flow and Thermodilution Technique
NCT05944146 ·Status: RECRUITING ·Phase: NA