Elastic Nail Versus Screw for Intramedullary Fixation of Displaced Fractures of the Fifth Metacarpal Neck
NCT06449755 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 46
Last updated 2024-06-10
Summary
The goal of this clinical trial is to compare two different intramedullary fixation technique in patient diagnosed with deplased fifth metacarpal neck fracture. The main questions it aims to answer are:
* Can percutaneous screw application be a more stable fixation method than intramedullary elastic nail application?
* Can screw application create a significant difference in the recovery of grip strength in the early period compared to elastic nail application? Patients will be followed up at the 1st week, 1st month and 3rd month postoperatively. Functionality will be evaluated with Quick DASH score at the 3rd month. At the 1st and 3rd month controls, grip strength will be evaluated. At the same time, metacarpal shortening and angulations will be measured on x-ray. Researchers will compare percutaneous screw and elastic nail group to see grip strength, healing time and radiologic parameter difference.
Conditions
- Metacarpal Fracture
- Boxer's Fracture
Interventions
- DIAGNOSTIC_TEST
-
Radiologic examination
Posoperative first week, month and third month On the x-ray of Hand AP view: metacarpal shortening On the x-ray of Hand 30 degree pronation view: dorsal angulation
- PROCEDURE
-
Grip Strength
Postoperative first month and third month grip streng compare with Cambry hand dinamometer.
- OTHER
-
Quick DASH Questionnaire
Quick DASH is an 11-question questionnaire that assesses upper extremity functionality.
Sponsors & Collaborators
-
Istanbul University
lead OTHER
Principal Investigators
-
Serkan MD Bayram, MD · Assistant Professor
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 60 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2023-09-01
- Primary Completion
- 2025-01-01
- Completion
- 2025-02-01
Countries
- Turkey (Türkiye)
Study Locations
More Related Trials
-
Comparison of New Suture Anchor Technique for Bony Mallet Injury Versus Conservative Treatment
NCT03228849 ·Status: COMPLETED ·Phase: NA
-
Comparison of Short Segment Mono-axial and Poly-axial Pedicle Screw Fixation for Thoracolumbar Fractures
NCT04032054 ·Status: UNKNOWN
-
Comparative Study Between Micro Plate Fixation and Blocking k.Wire in Management of Acute Bony Mallet Finger : Randomized Controlled Clinical Trial Study
NCT06398483 ·Status: RECRUITING ·Phase: NA
-
Headless Screw Fixation for Metacarpal Fractures in Adults.
NCT06543485 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Comparison of Dynamic Versus Static Lag Screw Modes for Cephalomedullary Nails Used to Fix Intertrochanteric Fragility Fractures
NCT04441723 ·Status: UNKNOWN ·Phase: NA
-
Syndactyly Versus Closed Reduction in 5th Metacarpal Neck Fracture
NCT03434587 ·Status: COMPLETED ·Phase: NA
-
Fixation of Shaft Femure Fracrture by Ender Versus Plate
NCT07067333 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Headless Screws x Bouquet in Boxer's Fracture
NCT03607045 ·Status: UNKNOWN ·Phase: NA
-
Comparison Different Method Treatment in Tuberosity Fractures of the Proximal Fifth Metatarsal
NCT04168411 ·Status: COMPLETED ·Phase: NA
-
Fixation of Displaced Distal Ulna Fractures in Adults by Flexible Intramedullary Nail
NCT05173181 ·Status: UNKNOWN ·Phase: NA
-
Femoral Neck Locking Plate Vs Multiple Cannulated Cancellous Screws in Treatment of Femoral Neck Fractures in Young Adults: Randomized Controlled Clinical Trial Study
NCT06162637 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Is the Expert Nail With Poller Screws Superior to the Distal Tibial Locked Plate in the Management of Short Oblique Distal Tibial Fractures?
NCT06436365 ·Status: COMPLETED ·Phase: NA
-
The Clinical and Radiological Outcomes of the Use of Titanium Elastic Nail in The Fixation of Fresh Non-comminuted Fracture Mid-shaft Clavicle
NCT05315284 ·Status: UNKNOWN ·Phase: NA
-
Buried Intramedullary K-wire Fixation Compared With Plate and Screw Fixation for Metacarpal Fractures in Unstable Extra-Articular Metacarpal Fractures
NCT02718170 ·Status: TERMINATED ·Phase: NA
-
Comminuted Fractures of the Midshaft of the Tibia; (Interlocking Nail +/- Blocking Screws or Locked Plating With Predicted Distribution of Locking Screws) Choice Based on Finite Element Analysis Correlated With Clinical Outcome and Union.
NCT04388462 ·Status: COMPLETED
-
Compartmental Overpressures Associated to Reamed Intramedullary Nails
NCT00842101 ·Status: COMPLETED
-
Study Comparing Intramedullary Nailing, Plate Fixation, and Non-operative Treatment of Clavicle Fractures
NCT01311219 ·Status: WITHDRAWN ·Phase: NA
-
Reconstruction Plate Compared With Flexible Intramedullary Nailing for Midshaft Clavicular Fractures
NCT01410032 ·Status: COMPLETED ·Phase: PHASE2
-
Cast Immobilization for Non-Displaced Scaphoid Fractures
NCT00916539 ·Status: COMPLETED ·Phase: NA
-
A Randomized Trial Comparing Conventional Plaster and Thermoplastic Splints to Treat Pediatric Boxer's Fractures
NCT01759758 ·Status: COMPLETED ·Phase: NA
-
A Multicenter Randomized Trial Comparing IM Nails and Plate Fixation in Proximal Tibial Fractures
NCT00429585 ·Status: COMPLETED ·Phase: NA
-
A Novel Splint Technique for Distal Radius Treatment
NCT04432740 ·Status: COMPLETED ·Phase: NA
-
A Comparative Study Between Positional and Lag Screws for the Fixation of Medial Malleolar Fractures
NCT05573516 ·Status: UNKNOWN ·Phase: NA
-
Three Cancellous Screws Versus Four Cancellous Screws for Femoral Neck Fixation
NCT04869332 ·Status: RECRUITING ·Phase: NA
-
Percutaneous Screw Fixation for Acute Scaphoid Fractures Through K-wire-assisted Reduction and Maintenance
NCT04482868 ·Status: COMPLETED ·Phase: NA