Comminuted Fractures of the Midshaft of the Tibia; (Interlocking Nail +/- Blocking Screws or Locked Plating With Predicted Distribution of Locking Screws) Choice Based on Finite Element Analysis Correlated With Clinical Outcome and Union.

NCT04388462 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 20

Last updated 2020-05-14

No results posted yet for this study

Summary

study is to assess the clinical and radiological results of Comminuted fractures of the midshaft of the tibia; treated with interlocking nail +/- blocking screws or locked plating with predicted distribution of locking screws, choice based on finite element analysis correlated with clinical outcome and union.

Conditions

  • Comminuted Fracture Tibia

Interventions

OTHER

Finite element analysis

Biomechanical study to describe micromotion

Sponsors & Collaborators

  • Cairo University

    lead OTHER

Eligibility

Min Age
25 Years
Max Age
45 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2018-01-05
Primary Completion
2019-03-01
Completion
2020-05-02

Countries

  • Egypt

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.