Monocentric Retrospective Observational Study; Analysis of Gore Excluder ACS Device Using Numerical Simulation
NCT06428877 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 20
Last updated 2024-05-24
Summary
andated when the risk of rupture is low and interventional treatment is offered to patients at high risk of rupture. Rupture risk is driven by aneurysm diameter and growth rate. Aneurysms with diameter greater than 55 mm and/or growth rate greater than 1 cm per year are at high risk of rupture. Open surgery and endovascular treatment are the two types of interventions. Open repair consists in replacing the aneurysmal part of the aorta using a synthetic fabric prosthesis after the abdomen has been opened and the aorta clamped. This invasive procedure is associated with a 3-10% post-operative mortality. Endovascular repair (EVAR) consists in excluding the aneurysm sac by inserting a self-expanding prosthesis (called stent-graft) through very small groin incisions, without abdominal opening nor aortic clamping. This minimally invasive procedure is associated with a significantly reduced post-operative mortality (around 1%) . However, hostile proximal neck anatomy including high angulation is associated with higher rates of type IA endoleak, reintervention and long-term mortality . For this reason, a conformable design of the Excluder stent-graft has been engineered with initial satisfactory results in patients with highly angulated or short necks . However, these satisfactory results have been obtained in carefully selected patients from experienced centers and a tool demonstrating adequate apposition of the Gore ACS is lacking. Study Device Description Numerical simulation has been used successfully to predict stent-graft behavior during FEVAR . Preliminary studies have also demonstrated to applicability of the technology to standard infrarenal devices , including in the setting of very tortuous anatomies9 . The potential of numerical simulation to predict stent-graft apposition of Gore ACS in highly angulated necks appears very promising to enhance patient selection.
Conditions
- Vascular Diseases
- Surgery
Interventions
- OTHER
-
analyzed on the post-operative scanner
analyzed on the post-operative scanner
Sponsors & Collaborators
-
Hospices Civils de Lyon
lead OTHER
Eligibility
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2023-06-15
- Primary Completion
- 2023-09-15
- Completion
- 2024-04-15
Countries
- France
Study Locations
More Related Trials
-
Use of Artificial Intelligence to Predict Complications Following Abdominal Aortic Surgery
NCT06884397 ·Status: RECRUITING
-
Arterial Properties of Thoracic Aorta Disease
NCT01068691 ·Status: UNKNOWN
-
Solitaire Aneurysm Remodeling Registry
NCT04905303 ·Status: WITHDRAWN
-
GORE® EXCLUDER® Endoprosthesis French Mandatory Registry
NCT02308839 ·Status: COMPLETED
-
Risk of Rupture of Aneurysms of the Thoracic Ascending Aorta (ATA) From the Dynamic Imaging
NCT02538822 ·Status: TERMINATED ·Phase: NA
-
CLARYS: CLinical Assessment of WEB® Device in Ruptured aneurYSms
NCT02687607 ·Status: COMPLETED
-
Mini-laparotomy Versus Mini Lumbotomy
NCT02888613 ·Status: UNKNOWN ·Phase: NA
-
Hemodynamic Changes in the Aorta After Endovascular Treatment of the Aortic Dissection
NCT03669055 ·Status: COMPLETED ·Phase: NA
-
Assessment of the GORE® EXCLUDER® Conformable AAA Endoprosthesis in the Treatment of Abdominal Aortic Aneurysms
NCT02489539 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Treatment in Thoracic Aortic Aneurysm: Surgery vs Surveillance
NCT03536312 ·Status: RECRUITING ·Phase: NA
-
Study of the Large Diameter GORE EXCLUDER® AAA Endoprosthesis in Abdominal Aneurysms
NCT00615069 ·Status: COMPLETED ·Phase: PHASE2
-
Analysis of Respiration-induced Deformities of the Visceral and Renal Arteries Before and After Stenting
NCT04724863 ·Status: COMPLETED ·Phase: NA
-
Measurement of Maximum Diameter of Native Abdominal Aortic Aneurysm by Angio-CT
NCT02875444 ·Status: COMPLETED
-
Incidence of Major Complication in Case of Thoracic Aortic Aneurysm
NCT05395598 ·Status: RECRUITING
-
Outcome Study of the Pipeline Embolization Device With Vantage Technology in Unruptured Aneurysms
NCT05626504 ·Status: ACTIVE_NOT_RECRUITING
-
Biomechanical and Microstructural Properties of Ascending Aortic Aneurysms
NCT03142074 ·Status: RECRUITING
-
Medical & Economical Evaluation of Fenestrated & Branched Stent-grafts to Treat Complex Thoracal Abdominal Aneurysms
NCT01354821 ·Status: UNKNOWN ·Phase: NA
-
Endovascular AAA Intervention Using the GORE® EXCLUDER® Conformable AAA Endoprosthesis or Iliac Branch Endoprosthesis
NCT06218875 ·Status: RECRUITING
-
Venous Distension in Patients With Aneurysmatic Arterial Disease
NCT02867501 ·Status: COMPLETED
-
AI-enhanced Imaging Analysis to Predict Post-EVAR
NCT06592105 ·Status: NOT_YET_RECRUITING
-
Elective Abdominal Aortic Aneurism - Open Versus Endovascular Repair
NCT00224718 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the GORE® EXCLUDER® Thoracoabdominal Branch Endoprosthesis in the Treatment of Thoracoabdominal and Pararenal Aortic Aneurysms
NCT03728985 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Prospective, Multicenter Study of the Second Generation Antimicrobial Graft in the Abdominal Position
NCT00824109 ·Status: UNKNOWN ·Phase: PHASE4
-
Ruptured Aorta-iliac Aneurysms: Endo vs. Surgery
NCT00577616 ·Status: COMPLETED ·Phase: NA
-
Virtual Simulation for Woven EndoBridge Device Sizing
NCT04621552 ·Status: COMPLETED