Exploration of Optical Coherence Tomography-Guided Transbronchial Biopsy in Peripheral Pulmonary Lesions
NCT06419114 · Status: RECRUITING · Type: OBSERVATIONAL · Enrollment: 150
Last updated 2024-05-20
Summary
In this prospective analysis, investigators collected and evaluated data from patients who underwent TBB at the Respiratory Endoscopy Center of Sichuan Provincial People's Hospital. The procedures utilized a novel approach combining OCT with R-EBUS for guidance. Eligibility for participation was determined based on established guidelines for the application of diagnostic flexible bronchoscopy in adults.
The admission criteria of this study were as followed: (1) voluntary participation and written informed consent signed, (2) age ≥ 18 years old, (3) the platelets count and PT, APTT tests were normal, (4) normal ECG, (5) found PPL's by chest computed tomography (CT) within 2 weeks and (6) could not detect the lesions through routine diagnostic bronchoscopy. The exclusion criteria of this study were as followed: (1) patients with contraindication of bronchoscopy (such as respiratory failure and acute cardio-cerebrovascular events), (2) patients who refuse biopsy because of physical reasons or personal wishes, (3) patients with the objective reasons (such as abundant blood supply around the lesion) who could not complete the biopsy, (4) patients who are participating in other clinical studies, (5) patients with poor compliance who are believed by the researchers to be unable to cooperate for the completion of the examination and follow-up, and (6) women who were pregnant.
R-EBUS and OCT In this study, all procedures were conducted using a standardized flexible bronchoscopy (Olympus, Japan) featuring an outer diameter of 4.2mm. R-EBUS system (Olympus, Japan) incorporated an ultra-thin radial ultrasonic probe (Olympus UM-S20-17S), which measures merely 1.4mm in diameter. The OCT (Yongshida Medical Technology, Guangdong, China) probe is a cylindrical catheter, 1.7mm in diameter and 150cm in length. Placing the probe through the working channel of bronchoscope for real time dynamic scanning of lesions.
Research Process In this study, the entirety of the procedures was performed by the same respiratory physician with 5 years of experience in respiratory endoscopic diagnosis and treatment, including preoperative evaluation, preparation, lesion localization and biopsy. The respiratory physician had examined the bilateral airways with flexible bronchoscopy after the completion of preoperative anesthesia and found no lesions. The subsequent step involved the precise placement of the OCT probe, guided by prior CT scan results. This stage was critical for marking the lesion, determining its nature (benign or malignant), and, in cases of malignancy, identifying its pathological classification. In instances where the OCT failed to identify any lesion, the R-EBUS was employed to facilitate lesion localization and biopsy. Conversely, when PPLs was detected via OCT, R-EBUS was additionally utilized to corroborate the PPLs localization and to assist in completing the biopsy procedure. For cases where OCT localization failed, R-EBUS would be used. After successful confirmation with R-EBUS, an attempt was made again to insert the OCT probe and completed biopsy. Rapid On-Site Evaluation (ROSE) was employed for the assessment of biopsy specimens. A total of five specimens were collected from each lesion and subjected to ROSE. In scenarios where ROSE provided a definitive diagnosis, no additional biopsies were deemed necessary. Conversely, in instances where ROSE yielded non-definitive results, further biopsy samples were obtained. All biopsy specimens were preserved in 10% formalin, preparing them for detailed histopathological analysis. The ultimate pathological diagnoses were determined based on the reports issued by the pathology department.
In this study, the demographics of all patients were documented, including age, gender, and smoking history. Additionally, detailed clinical parameters, such as the location and size of the lesions, airway grades (ranging from 0 to 24) that the PPLs located, location time of OCT and the number of specimens, were systematically recorded. investigators also conducted extensive follow-up to track histopathological outcomes, whether from surgical biopsies, CT-guided percutaneous transthoracic needle biopsies, or other diagnostic avenues, including chest CT performed two months post-procedure. All the patients were followed up by telephone or outpatient service on the 1st and 3rd day after the procedure, and adverse events were recorded. All individuals underwent general anesthesia and were fitted with a laryngeal mask.
Conditions
- Lung Neoplasm
Interventions
- DEVICE
-
Optical Coherence Tomography
Comparing the localization ability of OCT and R-EBUS in Peripheral Pulmonary Lesions and the predictive ability of lung cancer pathological classification
Sponsors & Collaborators
-
Sichuan Provincial People's Hospital
lead OTHER
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2024-03-01
- Primary Completion
- 2024-12-31
- Completion
- 2024-12-31
Countries
- China
Study Locations
More Related Trials
-
Narrow Band Imaging (NBI) Under Electronic Bronchoscope in Lung Cancer
NCT04676815 ·Status: UNKNOWN
-
The Effectiveness and Safety of Electromagnetic Navigation Real-time Guided Percutaneous Lung Biopsy
NCT05799014 ·Status: UNKNOWN ·Phase: NA
-
Diagnostic Yeld of Ultrathin Bronchoscopy in Peripheral Pulmonary Lesions
NCT05526573 ·Status: RECRUITING
-
Bronchoscopic Navigation Robot-guided Dye Marking-assisted Thoracoscopic Pulmonary Nodule Resection
NCT06821451 ·Status: RECRUITING ·Phase: NA
-
A Retrospective Study of Transbronchial Cryobiopsy in the Diagnosis of Progressive Pulmonary Fibrosis
NCT06275295 ·Status: NOT_YET_RECRUITING
-
UTB-VBN-EBUS With or Without Fluoroscopy for the Diagnosis of PPLs
NCT02664259 ·Status: COMPLETED ·Phase: NA
-
A Real-World Case Study Evaluating the Efficacy and Safety of RBS Cryobiopsy
NCT06832930 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Comparative Performance of Robotic, Electromagnetic Navigation and Fluoroscopy Drives Optimal Diagnostic Strategy for Peripheral Pulmonary Lesions
NCT06701448 ·Status: COMPLETED ·Phase: NA
-
The Feasibility of Low Dose Chest CT for Virtual Bronchoscopy Navigation - Human Study.
NCT04230317 ·Status: UNKNOWN ·Phase: NA
-
The Efficacy and Safety of TBCB vs TBFB in Diagnosis of GGO
NCT04727190 ·Status: UNKNOWN ·Phase: NA
-
A Comparison Between EBUS-GS and CT-guided Lung Biopsy in Diagnosis of Peripheral Pulmonary Lesions.
NCT02740400 ·Status: UNKNOWN ·Phase: NA
-
CBCT in Guiding Bronchoscopy in Patients With Lung Lesions
NCT02978170 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Effectiveness of Predicting the Integrity of Interlobar Fissures Based on Chest Image AI Technology
NCT05774730 ·Status: UNKNOWN
-
Electromagnetic Navigation for Peripheral Pulmonary Lesions
NCT02582944 ·Status: COMPLETED ·Phase: PHASE1
-
Feasibility of Mobile-CT-Assisted Bronchoscopy for the Diagnosis of Lung Lesion
NCT04995172 ·Status: COMPLETED
-
Spectrum Analysis in Ex-vivo Human Lungs
NCT03356743 ·Status: COMPLETED ·Phase: NA
-
Ultrathin Bronchoscope and Radial Endobronchial Ultrasound (R-EBUS) With Fluoroscopy Versus Standard Fiberoptic Bronchoscopy (FB) (P00029233 )
NCT02146131 ·Status: COMPLETED ·Phase: NA
-
VBN-EBUS-GS-TBLB With or Without Fluoroscopy for the Diagnosis of PPLs
NCT02484066 ·Status: COMPLETED ·Phase: NA
-
Application of Transbronchial Cryobiopsy in the Diagnosis of Progressive Pulmonary Fibrosis
NCT06251687 ·Status: RECRUITING ·Phase: NA
-
The Diagnostic Yield and Safety of Transbronchial Cryobiopsy in Diffuse Parenchymal Lung Diseases
NCT03704233 ·Status: UNKNOWN
-
mCBCT in Combination With ENB for the Diagnosis of PPNs
NCT05518669 ·Status: UNKNOWN
-
RAB Versus Ultrathin Bronchoscopy With VBN in the Diagnosis of PPNs
NCT06962436 ·Status: RECRUITING ·Phase: NA
-
Thin and Ultrathin Bronchoscopy With Transbronchial Needle Aspiration and Radial Probe Endobronchial Ultrasound for Peripheral Pulmonary Lesions
NCT04331587 ·Status: COMPLETED
-
The Diagnostic Yield and Safety of Transbronchial Cryobiopsy in The Pulmonary Periphral Nodule
NCT04661956 ·Status: UNKNOWN ·Phase: NA
-
Assess the Use of rEBUS With a Guide Sheath to Increase Transbronchial Lung Biopsy Yield Rate
NCT04056273 ·Status: UNKNOWN ·Phase: NA