High-definition Transcranial Electrical Stimulation for Upper Extremity Rehabilitation

NCT06409143 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 152

Last updated 2024-08-16

No results posted yet for this study

Summary

Upper limb hemiparesis is the most common sequelae in patients, severely impacting their independence and quality of life. Transcranial electrical stimulation (tCES) is a non-invasive and safe treatment, which uses a low direct current or alternating current to change the excitability of the cerebral cortex. It can induces long-term potentiation-like or long-term depression-like effects, thereby modulating the cortical excitability. In recent years, researchers have developed high-definition (HD) devices, which integrate high definition ring electrode configurations and incorporate direct current with theta burst stimulation waveforms. Diverging from traditional transcranial direct current stimulation (tDCS), which applies weak currents (0.5-2 mA) through two large sponge electrodes (25\~35 cm\^2) externally to the scalp for widespread non-specific cortical stimulation, HD-tES employs an array of small-area electrodes (1 cm\^2) to control current distribution over localized cortical regions, thereby enhancing spatial accuracy. However, there is a lack of studies validating the optimal waveform for HD-tES, as well as clinical evidence in subacute stroke populations. The optimal unilateral versus bilateral stimulation modes and their neurological mechanisms for stroke rehabilitation also remain uncertain.

Conditions

Interventions

DEVICE

HD-tES

The intensity of HD-tES is set at 2 mA, the current intensity ramps up to 2 mA within 5 seconds, remains at 2 mA for 10 minutes, and then ramps down to zero within 5 seconds. For the sham stimulation, the current intensity ramps up and down at the first and last 10 seconds, with the remaining 10 minutes set at 0 mA. The inhibitory and excitatory waveform will be selected based on results of sub-project 1.

DEVICE

Sham HD-tES

The intensity of HD-tES is set at 2 mA, the current intensity ramps up to 2 mA within 5 seconds, remains at 2 mA for 10 minutes, and then ramps down to zero within 5 seconds. For the sham stimulation, the current intensity ramps up and down at the first and last 10 seconds, with the remaining 10 minutes set at 0 mA. The inhibitory and excitatory waveform will be selected based on results of sub-project 1.

OTHER

UE rehabilitation

Upper extremity rehabilitation programs will be selected and graded in accordance with each patient's upper extremity function and specific aims of activities of daily living. Upper extremity rehabilitation will be provided for 60 minutes each time, 5 times a week, lasting for 3 weeks.

DEVICE

HD-tES (Bilateral)

The intensity of HD-tES is set at 2 mA, the current intensity ramps up to 2 mA within 5 seconds, remains at 2 mA for 10 minutes, and then ramps down to zero within 5 seconds.

Sponsors & Collaborators

  • National Taiwan University Hospital

    lead OTHER

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
TRIPLE
Model
PARALLEL

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
Yes

Timeline & Regulatory

Start
2024-08-15
Primary Completion
2026-08-31
Completion
2026-11-30

Countries

  • Taiwan

Study Locations

More Related Trials

Entities

Diseases

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.