Study of Lipolysis of Visceral Reserve Fat Using Tecar Therapy.
NCT06377358 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 20
Last updated 2025-07-17
Summary
The Scope of this study is to assess the visceral and subcutaneous fat loss in patients having Tecar (Radiofrequency) Therapy and its effects on other anthropometric variables, adipokines and inflammation.
20 obese patients will be treated with Tecar Therapy (Radiofrequency). Each patient will have 4 active, automatic plates placed on the abdomen (200 cm2 per plate), two on the right side of the midline and two on the left side. Energy will be applied for 50 minutes, controlling the temperature. Subsequently, 15 minutes of Capacitive and Resistive manual electrodes will be applied to the abdomen, simultaneously, 20 minutes of Lymphatic Drainage placing one active plate in the foot and the other in the lumbo-dorsal area. Patients will be informed that they will only feel comfortable warmth. Five sessions will be applied from Monday to Friday resting Saturday and Sunday, for 2 weeks. Total 10 sessions.
Subcutaneous and visceral fat will be measured by MRI. Anthropometric variables (Body Mass Index, Waist to Hip ratio and skinfold) will be also measured.
Metabolic and inflammatory effects of the RF treatment will be evaluated measuring adipokines (Leptin, adiponectin and resistin) as well as citokines (IL-6, TNF-a and C reactive Protein).
Results will be analyzed using the SPSS statistics package. A Kolmogorov-Smirnov test will be applied, if the data behaves normally, parametric tests will be applied. If not, non-parametric tests will be performed. The differences between proportions will be analyzed using Fischer's exact test. The differences between the medians will be assessed using the Student's t-test for paired samples and independent samples.
Conditions
- Obesity, Visceral
- Obesity; Endocrine
Interventions
- DEVICE
-
Tecar Therapy
Tecar Therapy at 1Mhz radiofrequency by the use of a C-400 device. The duration of the treatment will be 5 weeks, where 10 sessions will be carried out, 2 per week
Sponsors & Collaborators
-
University of Malaga
collaborator OTHER -
Alfonso X El Sabio University
collaborator OTHER -
CAPENERGY MEDICAL, SL
lead INDUSTRY
Principal Investigators
-
Jesús Rodríguez Lastra, PhD, MD · Alfonso X El Sabio University
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 20 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2022-05-09
- Primary Completion
- 2022-07-25
- Completion
- 2023-06-22
Countries
- Spain
Study Locations
More Related Trials
-
Cryolipolisis for Abdomen and Flank Fat Reduction
NCT03033004 ·Status: COMPLETED ·Phase: NA
-
Clinical Evaluation of the Safety and Efficacy of a 1060nm Diode Laser (Abdomen)
NCT03756350 ·Status: COMPLETED ·Phase: NA
-
Clinical Evaluation of a 1060 nm Diode Laser, PEMF and Vacuum Assisted MP RF for Non-invasive Fat Reduction
NCT04012814 ·Status: COMPLETED ·Phase: NA
-
Fat Reduction Induced by Magnetic Device - Waist Circumference Evaluation
NCT03547934 ·Status: WITHDRAWN ·Phase: NA
-
Changes in Abdominal Tissues Induced by Magnetic Device - CT Evaluation
NCT03545646 ·Status: WITHDRAWN ·Phase: NA
-
The Trusculpt (Radio Frequency) Device For Thigh Circumference Reduction
NCT01665118 ·Status: COMPLETED ·Phase: NA
-
Multi-Center Traditional Feasibility Study of Radiofrequency Device
NCT04584099 ·Status: TERMINATED ·Phase: NA
-
Performance Evaluation of the truSculpt Radiofrequency Device for Lipolysis of Abdominal Fat
NCT03433417 ·Status: COMPLETED ·Phase: NA
-
Fat Reduction Induced by Magnetic Device - Ultrasonographic Evaluation
NCT03537716 ·Status: WITHDRAWN ·Phase: NA
-
RF and PEMF Following Liposuction
NCT03588702 ·Status: COMPLETED ·Phase: NA
-
Effect of BTL-899 Device for Non-invasive Lipolysis on Human Flanks
NCT05260164 ·Status: COMPLETED ·Phase: NA
-
Pivotal Study of the truSculpt Radiofrequency Device for Circumferential Reduction
NCT02873104 ·Status: COMPLETED ·Phase: NA
-
Effects of Radiofrequency on Located Adiposity
NCT02546778 ·Status: COMPLETED ·Phase: NA
-
Subject Evaluation of a 1064nm Diode Laser/RF
NCT04090853 ·Status: WITHDRAWN ·Phase: NA
-
XP1000 RF Therapy on Waist Circumference Reduction
NCT02271672 ·Status: COMPLETED ·Phase: NA
-
Shock Waves for Treatment of Gynoid Lipodystrophy and Localized Fat
NCT03275259 ·Status: COMPLETED ·Phase: NA
-
Percutaneous Electroneurostimulation of Dermatome T6 for Appetite Reduction and Weight Loss in Morbidly Obese Patients
NCT01792947 ·Status: COMPLETED ·Phase: NA
-
Radio Frequency (RF) Device for Reduction in Size of Localized Areas of the Body
NCT00953160 ·Status: TERMINATED ·Phase: NA
-
mTORC1 and Autophagy in Human Brown Adipocytes
NCT04206124 ·Status: COMPLETED ·Phase: NA
-
Comparison of the Effects of Electric Current With Needles and Surface Electrodes on the Abdominal Contour of Women
NCT05973526 ·Status: UNKNOWN ·Phase: NA
-
Effect of the BTL-899 Therapy for Non-invasive Lipolysis and Circumference Reduction of Abdomen
NCT03270150 ·Status: COMPLETED ·Phase: NA
-
LED Device for Non-Invasive Lipolysis
NCT03171051 ·Status: TERMINATED ·Phase: NA
-
Effect of the XP1100RF Therapy on Thighs Circumference Reduction
NCT02527369 ·Status: COMPLETED ·Phase: NA
-
Fat Layer Reduction in the Lateral Thighs Using CoolSculpting
NCT02324816 ·Status: COMPLETED ·Phase: NA
-
Non-Invasive Reduction of Abdominal Fat Utilizing the CoolFlex and eZ App 6.3 Applicators
NCT01377740 ·Status: COMPLETED ·Phase: NA