The Use of Lung Ultrasonography in the Delivery Room in Neonates
NCT06314789 · Status: ENROLLING_BY_INVITATION · Phase: NA · Type: INTERVENTIONAL · Enrollment: 112
Last updated 2024-03-18
Summary
Lung ultrasonography has become frequently used in neonatal intensive care units because it is a diagnostic, useful, harmless, radiation-free, bedside, reproducible and practical method. (1, 2) In our clinic, lung ultrasonography imaging is performed in infants hospitalized with respiratory distress.
Lung ultrasonography is widely used especially in conditions that mainly cause respiratory distress such as respiratory distress syndrome (RDS), pneumonia, neonatal transient tachypnea (NTRT), congenital pneumonia, meconium aspiration syndrome and pneumothorax. (1, 2) The reliability and specificity of AUS imaging especially in the diagnosis of NTRT have been proven in many studies.
AUS imaging has become an objective value by scoring today. Images will be obtained using the linear probe of the device to be used for lung ultrasound and transferred to a cell phone, both lungs will be evaluated as three areas on the right and left (anterior upper, anterior lower and lateral) and scored separately. Anteriorly, the region between the anterior axillary line and the parasternal line is divided into two by the line passing through the nipple. Above is considered as the upper anterior region and below as the lower anterior region. The area in the middle of the anterior and posterior axillary line is evaluated as the lateral region. Each area is scored from 0 to 3 points. If A lines are present, 0 points are given, if there are more than 3 B lines in an area, 1 point is given, if B lines are very dense and there are no A lines, it is considered as white lung and 2 points are given. If there is a consolidation image on AUS, 3 points were given. The maximum total score was 18 (8,9) (Figure 1).
In this study, both AUS imaging and scoring will be performed in the delivery room within the first 30 minutes and AUS score evaluation will be performed at postnatal 2nd, 6th and 24th hours in the intensive care unit for inpatients and in the maternal ward for maternal patients. The hypothesis of this study is that newborns with high AUS scores will have high rates of respiratory morbidities and respiratory support in the neonatal unit. The primary aim of the study was to determine the role and importance of AUS scores measured in the delivery room in predicting respiratory morbidities of infants. The secondary aim was to investigate the value of the course of AUS scores at postnatal 2, 6 and 24 hours in predicting the respiratory prognosis of the newborn infant.
Conditions
- Suspected Damage to Fetus From Other Disease in the Mother, Affecting Management of Mother, With Delivery
- Patient Death or Serious Disability Associated With A Haemolytic Reaction Due to the Administration of ABO-Incompatible Blood or Blood Products
Interventions
- DIAGNOSTIC_TEST
-
doing lung ultrasonography
In the study, both LUS imaging and scoring will be performed in the delivery room within the first 30 minutes and LUS score evaluation will be performed at postnatal 2nd, 6th and 24th hours in the intensive care unit for inpatients and in the maternal ward for maternal patients.
Sponsors & Collaborators
-
Kırıkkale University
lead OTHER
Principal Investigators
-
Umit Ayse Tandircioglu · Kırıkkale University
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 1 Minute
- Max Age
- 1 Month
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2024-03-01
- Primary Completion
- 2025-03-01
- Completion
- 2025-03-01
Countries
- Turkey (Türkiye)
Study Locations
More Related Trials
-
LUNG ULTRASONOGRAPHY DECREASES RADIATION EXPOSURE
NCT04722016 ·Status: COMPLETED
-
Lung Ultrasound as a Predictor of Mechanical Ventilation in Neonates Older Than 32 Weeks
NCT02449863 ·Status: COMPLETED
-
Lung Sonar in Neonatal Respiratory Disorders
NCT06292338 ·Status: NOT_YET_RECRUITING
-
LUS AT BIRTH IN INFANTS BORN BEFORE 26 WEEKS
NCT06394583 ·Status: NOT_YET_RECRUITING
-
Lung Ultrasound to Diagnose Transient Tachypnea of the Newborn (TTN) Versus Respiratory Distress Syndrome (RDS) in Neonates
NCT01517958 ·Status: COMPLETED
-
Evaluation of Nasal Non Invasive Ventilation in Management of Neonates With Respiratory Distress Using Lung Ultrasound
NCT06550219 ·Status: RECRUITING ·Phase: NA
-
Bedside Ultrasound to Monitor Lung Function and Blood Flow in Newborns Treated With Surfactant
NCT07070167 ·Status: NOT_YET_RECRUITING
-
Corticosteroid Use in Premature Babies and Lung Ultrasonografi Use in the Progression to Bronchopulmonary Dysplasia
NCT05621785 ·Status: UNKNOWN
-
The Relationship of Fetal Lung Elastography Values With the Development of Respiratory Distress in Cases of Preterm Labor
NCT06168149 ·Status: COMPLETED
-
Heterogeneity Index in Neonatologist-performed Lung Ultrasound in Neonates Receiving Respiratory Support - a Pilot Study
NCT07117513 ·Status: NOT_YET_RECRUITING
-
Lung UltrasouNd Guided Surfactant Therapy in Preterm Infants (LUNG Study)
NCT05198375 ·Status: TERMINATED ·Phase: NA
-
Predictive Value of Lung Ultrasound for Respiratory Decompensation in Late Preterm Neonates
NCT07216053 ·Status: RECRUITING
-
Open Lung Strategy During Non-Invasive Respiratory Support of Very Preterm Infants in the Delivery Room
NCT05031650 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Serial Lung Ultrasound Data After Surfactant Treatments Applied With Different Methods in Preterm Babies
NCT06880016 ·Status: RECRUITING ·Phase: NA
-
Neonatologist-performed Lung Ultrasound (NPLUS) to Guide Respiratory Therapy to Prevent Extubation Failure
NCT06469580 ·Status: RECRUITING ·Phase: NA
-
Predictive Value of PS Application in Premature Infants With RDS
NCT05772247 ·Status: UNKNOWN
-
The Predictive Value of Amniotic Fluid pH and Electrolytes on Neonatal Respiratory Disorders
NCT02813954 ·Status: COMPLETED
-
Role Of Transthoracic Ultrasound in Predicting Post-extubation Distress During Successful Weaning
NCT06030401 ·Status: NOT_YET_RECRUITING
-
Performance of Lung Ultrasonography for Endotracheal Tube Positioning in Neonates
NCT03818139 ·Status: COMPLETED
-
Nasal High Frequency in Preterm Neonates
NCT06687083 ·Status: COMPLETED ·Phase: NA
-
Lung Ultrasound-Guided Positioning Strategy for the Prevention of Ventilator-Associated Pneumonia in Neonates
NCT07254507 ·Status: COMPLETED ·Phase: NA
-
Surfactant Replacement Guided by Early Lung Ultrasound Score in Preterm Newborns With Respiratory Distress Syndrome
NCT04775459 ·Status: COMPLETED
-
Utility of Lung Ultrasonography As a Predictor of Fast Track Extubation
NCT05317897 ·Status: COMPLETED
-
Combined Lung Ultrasounds and Transthoracic Electrical Bioimpedance in Preterm Infants With Respiratory Distress.
NCT04359134 ·Status: UNKNOWN
-
Lung Ultrasound - Prospective Study
NCT06140615 ·Status: COMPLETED ·Phase: NA