Comparison of Detection Rates Between Two Commonly Used Bone Density Measurement Methods
NCT06299865 · Status: NOT_YET_RECRUITING · Type: OBSERVATIONAL · Enrollment: 72
Last updated 2024-03-08
Summary
72 adult patients who underwent lumbar spine anteroposterior DXA and QCT examinations at Qianfoshan Hospital in Shandong Province from January 2019 to December 2022 were selected, with an interval of no more than 3 months between the two examinations for the same patient.
1. Record the patient's age, gender, height, and weight; Review the patient's past medical history (especially whether there is a history of brittle fractures, whether there is a history of using drugs that affect bone metabolism, etc.).
2. Retrieve the bone density values of the anterior lumbar vertebrae 1 to 4 measured by GE Healthcare Lunar Prodigy dual energy X-ray absorptiometry from the database, and take the average (DXA bone density value). According to the diagnostic criteria of the Diagnosis and Treatment Guidelines for Primary Osteoporosis (2022), determine whether the patient has normal bone mass, decreased bone mass, or osteoporosis.
3. Identify the lumbar spine bone density values (QCT bone density values) measured by the GE Gemstone CTHD750 CT instrument from the database. According to the diagnostic criteria of the Chinese Quantitative CT (QCT) Diagnosis Guidelines for Osteoporosis (2018), determine whether the patient has normal bone mass, decreased bone mass, or osteoporosis.
4. Statistical analysis was conducted on the normal bone density, bone loss, and number of osteoporosis diagnosed by DXA and QCT respectively, in order to explore the differences in the detection rates of osteoporosis between these two monitoring methods. The data was analyzed and processed using SPSS 21.0 statistical software, and the count data was expressed as a rate (%) χ 2-test, P\<0.05 indicates statistically significant difference; Explore whether the difference in detection rates between the two is related to factors such as weight; Calculate the detection rates of osteoporosis using two detection methods in patients who have experienced brittle fractures, and preliminarily determine which detection method is more accurate in determining osteoporosis.
Conditions
- Osteoporosis
- Diagnosis
- Dual Energy X-ray Absorptiometry
- Quantitative Computed Tomography
Interventions
- OTHER
-
Ungrouped
Ungrouped
Sponsors & Collaborators
-
Xiaoqian Zhang
lead OTHER
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2024-03-01
- Primary Completion
- 2024-12-31
- Completion
- 2024-12-31
Countries
- China
Study Locations
More Related Trials
-
Comparison of Xtreme CT and DXA Bone Densitometry
NCT01199991 ·Status: TERMINATED
-
Automated Bone Age Estimation From Noncontrast Abdominal CT Using Deep Learning
NCT07162168 ·Status: RECRUITING
-
Does Gender Play a Role in Bone-mineral Density Measurement Precision?
NCT01324713 ·Status: COMPLETED
-
CT-Based Deep Learning for Differentiating Acute and Chronic Osteoporotic Vertebral Compression Fractures
NCT07306858 ·Status: NOT_YET_RECRUITING
-
Texture Analysis for Postmenopausal Osteoporosis
NCT00145977 ·Status: COMPLETED ·Phase: NA
-
Diagnostic Performances of Mandibular CBCT in Osteoporosis
NCT05721118 ·Status: UNKNOWN
-
Multicenter Cohort Study on Osteoporosis
NCT02958020 ·Status: RECRUITING
-
Fracture and Fall Prevention in Elderly With Osteoporosis
NCT01844154 ·Status: UNKNOWN
-
Relationships Among Body Mass Index, Body Balance and Bone Mineral Density in Postmenopausal Women
NCT03280693 ·Status: COMPLETED
-
Radiological Biological Genetic and Micro-architectural Bone Determinants of Fractures in Men With Low Bone Mineral Density
NCT01250314 ·Status: COMPLETED ·Phase: NA
-
Analysis of Bone Micro-Architecture as a Clinical Biomarker for Image-Based Fracture Risk Estimation.
NCT03463850 ·Status: COMPLETED ·Phase: NA
-
Anthropometric And Body Composition Measurements Related To Osteoporosis In Geriatric Population
NCT04255173 ·Status: COMPLETED ·Phase: NA
-
AI Model for Bone Mineral Density Prediction From X-Ray Images
NCT06652061 ·Status: RECRUITING
-
What is the Best Policy to Prevent Osteoporotic Fracture?
NCT00173693 ·Status: WITHDRAWN ·Phase: NA
-
Associations Analysis Between Lifestyle and Osteoporosis
NCT02451397 ·Status: COMPLETED
-
Assessment of Cortical Bone Mechanics Technology (CBMT) Fracture Discrimination Capability
NCT05721898 ·Status: COMPLETED
-
Osteoporosis and Fall Prevention and Posture Correction Interventions in the Metropolitan Area
NCT02803190 ·Status: COMPLETED ·Phase: NA
-
Osteoporosis and Fall Prevention With Multiple Interventions in the Metropolitan Area
NCT02483286 ·Status: COMPLETED ·Phase: NA
-
Osteoporotic Precisely Screening Using Chest Radiograph and Artificial Neural Network (OPSCAN)
NCT05721157 ·Status: COMPLETED ·Phase: NA
-
Fracture and Fall Prevention in Elderly With Osteoporosis
NCT01733303 ·Status: UNKNOWN ·Phase: NA
-
Efficacy of Cone Beam Computed Tomography in Diagnosing Osteoporosis
NCT04365504 ·Status: UNKNOWN
-
A 5-Year Follow-up Study Investigating Factors Associated With Osteoporotic Fracture in Chinese Postmenopausal Women
NCT02247011 ·Status: COMPLETED ·Phase: NA
-
Association Between Dermatoporosis and Fractural Risk
NCT03998228 ·Status: COMPLETED
-
A Tiered Management System of Osteoporosis in China
NCT03916289 ·Status: UNKNOWN
-
Bone Mineral Density Agreement Study Between EOSedge™ Versus Traditional DXA
NCT06659055 ·Status: RECRUITING ·Phase: NA