Validation of Donor Oocytes Semi-automated Vitrification

NCT06238570 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 50

Last updated 2026-04-30

No results posted yet for this study

Summary

Oocyte vitrification is an effective method of freezing which has been authorized in France since 2011. The arrival of this technique has led to real improvements in the survival rate of oocytes after warming compared to that observed after slow freezing, a method previously applied. Oocytes reheated after vitrification show excellent results in terms of vitality and recovery of cellular functionality. Indeed, the fertilization rates observed after using warmed and fertilized oocytes in Assisted Reproduction Technology (ART) by intracytoplasmic sperm injection (ICSI) are similar to those obtained with fresh oocytes.

However, the manual vitrification techniques used until now involve a learning curve and a potential variability of the completion time depending on the operator and the number of oocytes to be vitrified.

Oocyte vitrification is a key step to optimize the chances of pregnancy in ART after using these oocytes. However, manual vitrification requires a learning curve, is technician-dependent and requires significant technical time.

A semi-automatic vitrification device (GAVI®, Merck), which recently appeared on the market, has demonstrated its effectiveness in terms of speed of production and reproducibility of vitrification of embryos obtained in ART. To our knowledge, no study has analyzed the effectiveness of semi-automatic vitrification (GAVI®, Merck) on survival and oocyte quality after warming. It would therefore be interesting to evaluate the effectiveness of this automaton on oocyte vitrification in the context of oocyte donation and to determine the impact of semi-automatic vitrification on oocytes compared to manual vitrification.

The main objective of this study is to demonstrate the non-inferiority of vitrification semi-automated device (Gavi) of oocytes with regard to the oocyte survival rate, compared to the manual technique used in ART.

The investigator will compare the effectiveness of semi-automated vitrification device with the manual technique, in terms of ART results by comparing the fertilization rates, the number and quality of embryos obtained as well as the implantation rates in oocyte recipient patients. This study will then allow clinical application of the most efficient protocol for oocyte vitrification in the context of oocyte donation. A cost/effectiveness study will be carried out.

Conditions

  • Vitrification
  • Egg Donor
  • Fertility
  • Assisted Reproductive Technology

Interventions

DEVICE

Gavi, Merck® (automated vitrification instrument)

This instrument recently appeared on the market and demonstrated a high effectiveness in terms of processing time and reproducibility for embryo vitrification. To date, no study has analyzed the efficiency of this automated vitrification instrument on oocyte vitrification. The oocytes will be stored in closed cassettes in liquid nitrogen

DEVICE

Vitrolife system

The oocytes vitrification will be carried out by an authorized technician according to the manual protocol validated and used routinely.

Sponsors & Collaborators

  • University Hospital, Clermont-Ferrand

    lead OTHER

Study Design

Allocation
NON_RANDOMIZED
Purpose
OTHER
Masking
NONE
Model
PARALLEL

Eligibility

Min Age
18 Years
Max Age
38 Years
Sex
FEMALE
Healthy Volunteers
No

Timeline & Regulatory

Start
2024-01-23
Primary Completion
2026-09-30
Completion
2026-12-31

Countries

  • France

Study Locations

More Related Trials

Entities

Diseases

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT06238570 on ClinicalTrials.gov