Heart Rate Variability of Premature Newborn

NCT06217133 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 65

Last updated 2024-01-22

No results posted yet for this study

Summary

To analyze the effects of two CPAP methods on the HRV of PTNBs during their routine routine in the HCUFU neonatal ICU. This is a randomized clinical trial, with controlled groups and cross over with healthy term newborns (RNT) as a control group admitted to the HC-UFU rooming-in and premature newborns (PTRN), between 28 and 32 weeks pregnant women with nasal CPAP group admitted to the neonatal ICU of the same hospital. The HRV recorded by the POLAR® RS800cx cardiac monitor will be analyzed, with a sampling rate of 1000 Hz.

The main question\[s\] it aims to answer are:

* Is there a difference in heart rate variability between newborns using conventional nasal CPAP and nasal bubble CPAP?
* Is it possible to conclude that one of the methods has a greater sympathetic or parasympathetic tone compared to the other?

Premature participants will be in the incubators in a supine position with 30 minutes rest after the last handling. Each data collection will last 60 minutes and will be carried out three times a day in the morning, afternoon and night shifts, for each 1-hour collection, HRV will be analyzed in 12 5-minute intervals, establishing an average for each variable of the data. HRV during a 1-hour period.

The researchers will compare the conventional CPAP and bubble CPAP group according to randomization.

* In the control group, data collection will be carried out in the Rooming Room in a single reference collection lasting 20 minutes, and analyzed in 4 5-minute intervals.
* The participant selected for conventional CPAP will receive conventional CPAP for 24 hours, then receive bubble CPAP for 24 hours the following day. The opposite will be done for the participant drawn for CPAP bubbles.

The comparison between the conventional CPAP and bubble CPAP groups will occur to find out whether it is possible to identify the type of non-invasive ventilation that allows an increase in HRV and parasympathetic tone variables, as well as a reduction in sympathetic tone variables and the stress index of premature babies.

Conditions

  • Autonomic Nervous System Imbalance

Interventions

DEVICE

CPAP

Conventional CPAP will be administered according to the unit's routine on ventilators of different brands and models according to service availability. Binary prongs, from brands available in the service, will be used as an interface without touching the nasal septum with the size recommended by the manufacturer and in accordance with the protocol established in the unit. TThe CPAP bubbles will be administered using the CPAP NEONATAL BABYPAP® MODEL 1150 S equipment, which is an electromedical device for non-invasive ventilatory assistance for newborns that generates continuous pressure in the airways (CPAP) controlled by means of a column of water that bubbles, through a flow of heated and humidified medical gas mixture supplied by a breathing circuit to the patient's nasal passage.

Sponsors & Collaborators

  • Adriano de Oliveira Andrade

    collaborator UNKNOWN
  • Federal University of Uberlandia

    lead OTHER

Principal Investigators

  • Lilian Rodrigues de Abreu Macedo, 3 · Federal University of Uberlandia

Study Design

Allocation
RANDOMIZED
Purpose
HEALTH_SERVICES_RESEARCH
Masking
NONE
Model
CROSSOVER

Eligibility

Min Age
28 Weeks
Max Age
32 Weeks
Sex
ALL
Healthy Volunteers
Yes

Timeline & Regulatory

Start
2024-06-01
Primary Completion
2025-05-31
Completion
2025-06-01

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT06217133 on ClinicalTrials.gov