Management Of Patellar Fractures By Craniofacial Mesh Plate Osteosynthesis Augmented by Screws
NCT06205914 · Status: RECRUITING · Phase: PHASE1 · Type: INTERVENTIONAL · Enrollment: 30
Last updated 2024-01-16
Summary
Patellar fractures are challenging orthopedic injuries. Fractures that result in disruption of the extensor mechanism led to significant functional deficits. The goals of treatment for patella fractures include restoration of articular congruity, painless full range of motion of the knee, and recovery of extensor mechanism function.
The biomechanical construct chosen to fix patellar fractures is very important because of the subcutaneous location of the patella and the high level of force transmission that occurs through the patella during flexion and extension of the knee. Some studies have shown that during specific actions like walking or climbing downhill, the patella can see forces as high as 3200 N, equaling four to five times the standard body weight of a person. Achieving biomechanical stability during patellar fracture fixation is imperative as the stability of fixation is tested thousands of times as the knee is put through numerous cycles of flexion and extension during the recovery period. While tension band wiring with or without -K- wire, screw, or cerclage wire augmentation the most widely accepted form of treatment for patellar fractures, plate osteosynthesis is gaining popularity for certain fracture patterns. We present below a novel form of patellar fracture fixation using MatrixNEURO Contourable Mesh plates (Synthes®). Made of titanium with an incredibly low profile, these plates were initially designed for use in midface and craniofacial skeletal trauma.
However, we found that using these plates in treatment of patellar fractures has allowed stable fixation of complex, severely comminuted injuries The benefit of plate is adequate and stable reduction and maintenance of this reduction
Conditions
- Patella Fracture
Interventions
- PROCEDURE
-
fixation of patella fractures by craniofacial mesh plate osteosynthesis augmented by screws
patellar fracture fixation using MatrixNEURO Contourable Mesh plates (Synthes®). Made of titanium with an incredibly low profile
Sponsors & Collaborators
-
Sohag University
lead OTHER
Study Design
- Allocation
- NA
- Purpose
- OTHER
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 16 Years
- Max Age
- 60 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2024-01-01
- Primary Completion
- 2024-08-31
- Completion
- 2024-08-31
Countries
- Egypt
Study Locations
More Related Trials
-
Outcomes of Hemiarthroplasty Versus Cephalo-medullary Fixation to Treat Unstable Intertrochanteric Femoral Fractures
NCT05134805 ·Status: UNKNOWN ·Phase: NA
-
Morphological Characteristics of Inferior Pole Patellar Fractures and a Finite Element Analysis Combined with a Retrospective Clinical Study of Anchor Suture and Titanium Cable Cerclage Treatment
NCT06736639 ·Status: COMPLETED
-
New Bone Fixation Plate for the Repair of Tibial Avulsion Fracture of Posterior Cruciate Ligament of the Knee
NCT03059368 ·Status: COMPLETED ·Phase: NA
-
Two-stage ORIF Vs Ex. Fix. in Complex Pilon Fractures
NCT05141227 ·Status: COMPLETED ·Phase: NA
-
Femoral Neck Locking Plate Vs Multiple Cannulated Cancellous Screws in Treatment of Femoral Neck Fractures in Young Adults: Randomized Controlled Clinical Trial Study
NCT06162637 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Percutaneous Kirschner Wires With Mutual Linking Technique in the Management of Proximal Humeral Fracture
NCT06659107 ·Status: COMPLETED ·Phase: NA
-
Intertrochanteric Femur Fracture Patients Who Receive Metformin With a Placebo
NCT07179042 ·Status: ENROLLING_BY_INVITATION ·Phase: EARLY_PHASE1
-
Primary Dynamization Versus Standard Interlocking Intramedullary Nail in Treatment of Tibial Shaft Fractures in Adults
NCT06147219 ·Status: RECRUITING ·Phase: NA
-
Plate Fixation of Distal Femur Fractures: A Protocol for a Study of Two Plate Options
NCT00644397 ·Status: COMPLETED
-
Safety and Effectiveness of Proximal Femoral Nail Antirotation for the Treatment of Intertrochanteric Femoral Fracture
NCT02880501 ·Status: UNKNOWN ·Phase: NA
-
Hemiepiphysiodesis by Eight Plate Versus Osteotomy in the Management of Pediatric Coronal Knee Deformities
NCT06630975 ·Status: RECRUITING ·Phase: NA
-
New Prosthesis for Comminuted Fracture of Lateral Half of Clavicle
NCT03577678 ·Status: COMPLETED ·Phase: NA
-
Platelet-rich Plasma Combined With Conventional Surgery in the Treatment of Atrophic Nonunion of Femoral Shaft Fractures
NCT03129971 ·Status: UNKNOWN ·Phase: NA
-
Length of the Femoral Stem in Arthroplasty Done for Patients With Proximal Femoral Metastatic Lesion
NCT04660591 ·Status: COMPLETED ·Phase: NA
-
Is There a Role for Hip Arthroscopy in Patients With Femoral Head Fractures?
NCT06491420 ·Status: RECRUITING ·Phase: NA
-
Evaluation of Direct Infrapectineal Plating in Quadrilateral Plate Acetabular Fractures
NCT07170280 ·Status: COMPLETED ·Phase: PHASE4
-
Comparison of Tibial Plateau Fractures Outcomes Treated With Non-locking and Locking Plate
NCT02035917 ·Status: UNKNOWN ·Phase: NA
-
Patient Satisfaction Vertical Ramus Osteotomy Patient Specificosteosynthesis Fixation Versus MMFmandibular Prognanthism
NCT03855072 ·Status: UNKNOWN ·Phase: NA
-
Posterior Plating Versus Anterior to Posterior Screws in Fixation of Posterior Column in Pilon Fractures
NCT05303389 ·Status: COMPLETED ·Phase: NA
-
Radiological and Functional Outcomes of Internal Fixation Methods for Ipsilateral Femoral Neck and Shaft Fractures in Young Adult Patients
NCT06826521 ·Status: NOT_YET_RECRUITING
-
Interlocking Polyetheretherketone Implants for Orbital Floor Reconstruction
NCT06661785 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Evaluation of Clinical and Radiological Outcomes in Patients Undergoing Fixation of Osteochondral Fragments With Reasorbable Screws in the Knee Joint
NCT06462040 ·Status: RECRUITING
-
High-Strength Suture vs. Traditional Tension Band for Patellar Fractures
NCT07248982 ·Status: RECRUITING
-
Miniplate Versus k Wires in Management of Metacarpal Fracture
NCT04605341 ·Status: UNKNOWN ·Phase: NA
-
The Use of a Minimally Invasive Internal Fixation Device for Treatment of Unstable Pelvic Ring Fractures
NCT05871866 ·Status: UNKNOWN ·Phase: NA