ABL90 FLEX PLUS Clinical Precision Study for 15 Parameters in Adult Whole Blood
NCT05804487 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 100
Last updated 2023-09-15
Summary
Conducting the ABL90 FLEX PLUS Clinical Precision Study for 15 Parameters in Adult Whole Blood is to validate performance claims for precision in heparinized whole blood for 15 parameters: pH, pCO2, pO2, cCa2+, cCl-, cK+, cNa+, cGlu, cLac, ctHb, sO2, FO2Hb, FMetHb, FCOHb, and FHHb, while being influenced by testing environment that is representative of intended use environment, site variability, and operator variability in a point-of-care (POC) setting.
The investigational device is the ABL90 FLEX PLUS (Figure 1) incl. consumables, running SW3.5 MR2, manufactured by Radiometer Medical ApS The study is being conducted in Denmark and in total, a minimum of 105 subjects are to be enrolled to provide successful measurement values from 3 different sites.
Conditions
- Diagnostic Test
Interventions
- DEVICE
-
ABL90 FLEX PLUS analyser running SW3.5 MR2.
The ABL90 FLEX PLUS analyzer is a portable, automated analyzer that measures pH, blood gases, electrolytes, metabolites, and oximetry in whole blood - utilizing 3 measuring modes (syringe, short probe, and capillary mode) to measure samples from a syringe, test tube or a capillary tube. The analyzer provides results for 17 parameters in 35 seconds using 65 μL heparinized whole blood.
Sponsors & Collaborators
-
Radiometer Medical ApS
lead INDUSTRY
Principal Investigators
-
Tejs Jansen · External Coordinating Principal Investigator
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2023-03-14
- Primary Completion
- 2023-08-31
- Completion
- 2023-08-31
- FDA Device
- Yes
Countries
- Denmark
Study Locations
More Related Trials
-
Evaluation of the New Acceleromyograph TOF 3D
NCT05005676 ·Status: UNKNOWN ·Phase: NA
-
AQT90 FLEX NTproBNP2 Test Kit Matrix Comparison and Sample Stability Verification Study
NCT06905392 ·Status: COMPLETED
-
DxFLEX 10C Clinical Study
NCT05467449 ·Status: COMPLETED
-
A Trial to Evaluate the Precision and Accuracy of the NBM-200 Series When Used in a Continuous Prospective Mode
NCT01917487 ·Status: UNKNOWN
-
Evaluate the Accuracy of the NBM200 for Noninvasive Hemoglobin Measurements on Obstetric/Gynecological Patients
NCT01917851 ·Status: UNKNOWN
-
Clinical Evaluation of the iMOST-X1 Hematology Analyzer - Matrix Study
NCT04778553 ·Status: COMPLETED
-
Electromagnetic Tracking of Devices During Interventional Procedures
NCT01279148 ·Status: WITHDRAWN
-
Comparison of Performance of a Conventional Blood Gas Analyser With the Proxima System
NCT01921023 ·Status: COMPLETED
-
Swab Sample Collection for the Detection of Bacterial Proteases
NCT01881815 ·Status: COMPLETED
-
Use of Rotational Thromboelastometry (ROTEM) to Characterize Coagulation Abnormalities in Burn Patients
NCT02388776 ·Status: TERMINATED ·Phase: NA
-
Autonomous Blood Drawing Optimization and Performance Testing
NCT05878483 ·Status: RECRUITING ·Phase: NA
-
Evaluation of the Clinical Performance of the Quantra System With the Quantra Surgical Cartridge
NCT03152461 ·Status: COMPLETED
-
A Normal Donor Sample Collection Study in Healthy Adults
NCT01318863 ·Status: COMPLETED
-
Clinical Evaluation of e- Ab Sensor - Based Real-time Diagnosis of Serum Procalcitonin Level
NCT01388114 ·Status: COMPLETED ·Phase: NA
-
Controlled Acute Hypoxia Study - Abbreviated Sensor Line
NCT02216344 ·Status: COMPLETED
-
Clinical Evaluation of i-STAT Analyzer Glucose, Hematocrit and Sodium for Capillary Samples
NCT02897154 ·Status: COMPLETED
-
Clinical Performance Evaluation of Native Whole Blood Samples of Patients on DOACs With the Perosphere ClotChek™
NCT07012291 ·Status: RECRUITING
-
Safety and Performance of Short- and Long-term Baseplates for Attaching the UNEEG Episight Recorder - Part I
NCT05111847 ·Status: COMPLETED ·Phase: NA
-
Comparison of Acceleromyography (AMG) and Mechanomyography (MMG) for Establishing Potency of Neuromuscular Blocking Agents
NCT00660413 ·Status: COMPLETED ·Phase: PHASE4
-
Utilizing Novel Blood RNA Biomarkers as a Diagnostic Tool in the Identification of Long COVID-19
NCT06311435 ·Status: RECRUITING ·Phase: NA
-
Dried Blood Spots for SARS-CoV-2 Serology (COVID-19).
NCT04880122 ·Status: COMPLETED ·Phase: NA
-
Noninvasive Hemoglobin Testing, Prospective Blood Donors
NCT04450381 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the LumiraDx Point of Care D-Dimer and CRP Tests
NCT04375982 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Evaluation of the Accuracy of the Hemochron Signature Elite Point of Care Device Compared With Laboratory Assay
NCT02255214 ·Status: COMPLETED
-
StatStrip Lactate, Hemoglobin, and Hematocrit Meter in Whole Blood
NCT05118048 ·Status: TERMINATED