ALN OATF Vena Cava Filter
NCT05785676 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 50
Last updated 2026-04-09
Summary
Migration of a thrombus in the pulmonary circulation is the leading cause of pulmonary embolism (PE). It can be prevented mechanically by implanting a vena cava filter (VCF) in the inferior vena cava. The implation of a VCF is indicated for patients with acute PE and a contraindication to anticoagulation, with an acute deep vein thrombosis (DVT) without PE and a contraindication to anticoagulation or with acute venous thromboembolism (less than 3 months) in whom an interventional gesture at hemorrhagic and thromboembolic risk contraindicates anticoagulation.
The purpose of this study is to describe the rates of implantation, removal and complications associated with the use of the optional ALN OATF VCF in current practice.
Conditions
Interventions
- DEVICE
-
Filter implantation
Implantation of OATF ALN vena cava filter
Sponsors & Collaborators
-
Aln2b SARL
collaborator UNKNOWN -
Assistance Publique - Hôpitaux de Paris
lead OTHER
Principal Investigators
-
Olivier PELLERIN, MD - PhD · Assistance Publique - Hôpitaux de Paris
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2023-02-14
- Primary Completion
- 2024-07-31
- Completion
- 2025-07-31
Countries
- France
Study Locations
More Related Trials
-
Crux Biomedical Evaluation of the Crux Inferior Vena Cava Filter System 3 ("RETRIEVE 3")
NCT01120522 ·Status: COMPLETED ·Phase: PHASE3
-
Crux Biomedical Evaluation of the Crux Inferior Vena Cava Filter 4
NCT01120535 ·Status: COMPLETED ·Phase: PHASE3
-
ODEN Trial: Option vs. Denali IVC Filters
NCT02201277 ·Status: TERMINATED ·Phase: NA
-
Safety and Initial Performance of the MediSieve Magnetic Haemofiltration System
NCT03786536 ·Status: WITHDRAWN ·Phase: NA
-
Filter Initial & Long Term Evaluation After Placement and Retrieval Registry
NCT01158482 ·Status: RECRUITING
-
Study of IVC Filter Retrieval With the Günther Tulip Vena Cava Filter
NCT00196118 ·Status: COMPLETED ·Phase: PHASE4
-
Predictors of Attempted Inferior Vena Cava Filters Retrieval.
NCT04846725 ·Status: COMPLETED
-
Evaluation of the Technical Success of IVUS Guided VCF Placement Using the LUMIFI™ With Crux® VCF System
NCT02394912 ·Status: TERMINATED ·Phase: NA
-
Assessment of Distal Protection Device in Patients at High Risk for Distal Embolism in Acute Coronary Syndrome (ACS)
NCT01460966 ·Status: COMPLETED ·Phase: NA
-
Retrievability and Incidence of Complex Retrieval in Celect Versus Denali Filter
NCT03987321 ·Status: UNKNOWN ·Phase: NA
-
RexMedical- Option* Vena Cava Filter IDE Study
NCT00488865 ·Status: COMPLETED ·Phase: NA
-
VenaTech Convertible Vena Cava Filter U.S. Multi-Center Clinical Trial
NCT01112917 ·Status: COMPLETED ·Phase: NA
-
Cook IVC Filter Study
NCT02046096 ·Status: COMPLETED ·Phase: NA
-
RECANA OUS - Recana Thrombectomy Catheter System for Venous Obstruction and Occlusion Study (RECANA-OUS-UK)
NCT07219758 ·Status: RECRUITING ·Phase: NA
-
Use of In-Line Filtration in Critically Ill Children
NCT00209768 ·Status: COMPLETED ·Phase: PHASE4
-
Using a Novel Algorithm to Improve the Retrieval Rate of Inferior Vena Cava Filters (iRetrieve Study)
NCT02160964 ·Status: UNKNOWN
-
Real World Use and Outcomes of VASCADE Closure Device Versus Manual Compression in Patients With CFA Disease
NCT04745624 ·Status: COMPLETED
-
Midline Catheter and Its Impact on Central Lines Removal in ICU
NCT03675711 ·Status: TERMINATED ·Phase: NA
-
Crux Biomedical IVC Filter - Evaluation of the Crux Inferior Vena Cava Filter System (Retrieve)
NCT00605332 ·Status: COMPLETED ·Phase: PHASE2
-
Trial of a Novel Fibrinolytic (Alfimeprase) to Clear Thrombosed Vascular Access Devices
NCT00073515 ·Status: COMPLETED ·Phase: PHASE2
-
The AbsorbaSeal Vascular Closure Device Trial
NCT03730571 ·Status: TERMINATED ·Phase: NA
-
Novel Strategy to Encourage Early Removal of Central Venous Catheters
NCT04136561 ·Status: WITHDRAWN ·Phase: NA
-
RIPT Feasibility Trial
NCT03070834 ·Status: COMPLETED ·Phase: NA
-
A PMCF Study Confirm the Performance and Safety of the TufTex Over-the-Wire (OTW) Embolectomy Catheters
NCT05386342 ·Status: RECRUITING ·Phase: NA
-
Clinical Investigation of Filter Improvement for New Filter to Ostomy Bags
NCT01272869 ·Status: COMPLETED ·Phase: NA