Prospective National Multi-center Registry of Obstructive Sleep Apnea Syndrome in Hypertensive Patients in China
NCT05735444 · Status: RECRUITING · Type: OBSERVATIONAL · Enrollment: 633
Last updated 2023-02-21
Summary
Study name: Screening, Diagnosis and Treatment of Obstructive Sleep Apnea Syndrome in Hypertensive Patients in China: A Prospective National Multi-center Registry.
Rationale: Obstructive sleep apnoea syndrome (OSAS) is a common secondary cause of hypertension and significantly correlated with the risk of cardiovascular and cerebrovascular diseases. However, continuous positive airway pressure (CPAP) only shows modest blood pressure lowering effect, although it is effective in the relieve of daytime sleepiness and other symptoms of OSAS. One of the possible reasons for the low antihypertensive efficacy might be the low adherence to CPAP therapy. Nonetheless, few studies systematically investigated CPAP adherence with regard to its prediction and clinical relevance for cardiovascular protection and prevention.
Objective: 1) To evaluate short- and long-term CPAP adherence in patients with hypertension and obstructive sleep apnea syndrome; 2) To investigate the predictors of short- and long-term CPAP adherence; 3) To explore the correlation between the CPAP adherence and blood pressure, target organ damage and the incidence of cardiovascular and cerebrovascular events.
Study design: Prospective, multi-center, observational study.
Study population: Patients with hypertension who are suspected to have obstructive sleep apnea syndrome due to snoring, daytime sleepiness and other related symptoms are considered eligible and should meet the following criterias: 1) Agree to participate in the study and sign the informed consent; 2) At least 18 years old; 3) STOP-Bang questionnaire, score ≥3 points; 4) Complete polysomnography in hospital; 5) Currently on CPAP therapy.
Follow up: 3, 6 and 12 months after registry.
Sample size estimation: At least 633 patients.
Timeline: Start of subjects' enrollment: Jan 2023; End of subjects' enrollment: December 2026; End of study: December 2026.
Organization: The Centre for Epidemiological Studies and Clinical Trials, Ruijin Hospital, Shanghai, China.
Conditions
Interventions
- DEVICE
-
Continuous positive airway pressure
Continuous positive airway pressure (CPAP) is one of the standard medical treatments for patients with OSAS. The mechanism of CPAP probably involves maintenance of a positive pharyngeal transmural pressure so that the intraluminal pressure exceeds the surrounding pressure. CPAP also increases end-expiratory lung volume, which stabilises the upper airway through caudal traction.
Sponsors & Collaborators
-
Shanghai Jiao Tong University School of Medicine
lead OTHER
Principal Investigators
-
Jiguang Wang, MD, PhD · Shanghai Institite of Hypertension, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2023-01-01
- Primary Completion
- 2026-12-31
- Completion
- 2026-12-31
Countries
- China
Study Locations
More Related Trials
-
Effect of Continuous Positive Airway Pressure (CPAP) on Systemic Blood Pressure, Coagulability and Carotid Intima-media Thickness in Patients With Sleep Apnea
NCT00300599 ·Status: COMPLETED ·Phase: NA
-
A Cross-sectional Study of the Occurrence and Effect of Obstructive Sleep Apnea in Subjects With Resistant Hypertension
NCT00843583 ·Status: COMPLETED
-
New Perspective on Exploring the Post-apneic BP Surge in Patients With OSA
NCT06172998 ·Status: RECRUITING ·Phase: EARLY_PHASE1
-
Effect of Nasal Continuous Positive Airway Pressure (CPAP) Blood Pressure and Vascular Endothelial Growth Factor in Obstructive Sleep Apnea Syndrome
NCT00300872 ·Status: COMPLETED ·Phase: NA
-
Efficacy of CPAP Treatment on Blood Pressure of Resistant Hypertension Patients With Obstructive Sleep Apnea Syndrome
NCT01508754 ·Status: COMPLETED ·Phase: PHASE4
-
Comprehensive Care of Sleep Disordered Breathing
NCT07339371 ·Status: NOT_YET_RECRUITING
-
Continuous Monitoring Nocturnal Beat-to-beat Blood Pressure Fluctuation in OSA With or Without Hypertension
NCT02876471 ·Status: COMPLETED ·Phase: NA
-
Study of Anatomo-functional Correlation of the Upper Airways
NCT05774522 ·Status: UNKNOWN ·Phase: NA
-
Screening of Obstructive Sleep Apnea Syndrome in Patients With Resistant Systemic Arterial Hypertension: Pilot Study
NCT03257488 ·Status: UNKNOWN ·Phase: NA
-
Comprehensive Respiratory Training Exercise Program in Obstructive Sleep Apnea
NCT05739617 ·Status: RECRUITING ·Phase: NA
-
The Impact of Sleep Apnea Treatment on Physiology Traits in Chinese Patients With Obstructive Sleep Apnea
NCT02696629 ·Status: UNKNOWN
-
Antihypertensive Effect of Continuous Positive Airway Pressure in Resistant Hypertensive Patients With Sleep Apnea
NCT00929175 ·Status: COMPLETED ·Phase: PHASE4
-
Precision OSA Therapy Based on Phenotypes and Endotypes
NCT06825923 ·Status: NOT_YET_RECRUITING
-
Autonomic Function in Obstructive Sleep Apnea
NCT00681161 ·Status: COMPLETED ·Phase: NA
-
Relationship Between Vascular Endothelial Dysfunction and Beat-to-beat Blood Pressure Variability in Patients With OSAS
NCT05548569 ·Status: RECRUITING
-
Acoustic Pharyngometry in Obstructive Sleep Apnea Syndrome Patients, With Indication of Continuous Positive Air Pressure
NCT01210703 ·Status: UNKNOWN
-
Effect of Upper Airway Stimulation on Vascular Function in Obstructive Sleep Apnea
NCT03051165 ·Status: TERMINATED ·Phase: NA
-
Validation of Five Seasons Sleep Tracking Mat for the Diagnosis of Obstructive Sleep Apnea
NCT06875479 ·Status: RECRUITING
-
Long-term Effect of High Flow Nasal Canula Therapy on Obstructive Sleep Apnea
NCT05549310 ·Status: UNKNOWN ·Phase: NA
-
Obstructive Sleep Apnea in the Absence of Metabolic Syndrome
NCT01635010 ·Status: COMPLETED ·Phase: PHASE4
-
Efficacy of Simple Continuous Positive Airway Pressure on Patients With Obstructive Sleep Apnea
NCT03782844 ·Status: COMPLETED ·Phase: NA
-
Clinical Efficacy of High-flow Nasal Cannula Oxygen Therapy in Patients With Obstructive Sleep Apnea
NCT05549245 ·Status: UNKNOWN ·Phase: NA
-
Prevalence of OSAS in Chinese Elderly and Its CPAP Compliance
NCT02085720 ·Status: COMPLETED ·Phase: NA
-
Risk Prediction of Difficult Tracheal Intubation in OSAHS Patient
NCT04506346 ·Status: UNKNOWN
-
Home Nasal Pressure for Sleep Apnea Management in Primary Case
NCT02141165 ·Status: COMPLETED ·Phase: NA