Non-Invasive Cardiac Output Monitor (NICOM) for Goal-directed Fluid Resuscitation for Inpatients With Hypotension and/or Septic Shock
NCT05630716 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 251
Last updated 2025-08-27
Summary
The Non-Invasive Cardiac Output Monitor (NICOM) is a non-invasive monitor capable of measuring cardiac output (CO) and cardiac index (CI), and stroke volume (SV) and stroke volume index (SVI) based on heart rate. Conceptually NICOM is a technology that utilizes a dynamic response characteristic in assessing the need for fluid administration, whereby SVI is measured before and after a fluid challenge with more fluid given only if SVI increases significantly with administered fluid. Dynamic response technologies are intended to replace older, "static" measures such as central venous pressure (CVP) and pulmonary capillary wedge pressures (PCWP) which are single point measurements utilized to assess the need to administer fluid.
The aim is to pilot and evaluate the effectiveness of using The Non-Invasive Cardiac Output Monitor (NICOM) technology for goal-directed fluid resuscitation in adult inpatients with sepsis associated acute hypotension and/or evidence of septic shock (Lactate \>= 4.0).
Conditions
- Sepsis
- Hypotension
- Septic Shock
Interventions
- DEVICE
-
NICOM
non-invasive monitor capable of measuring cardiac output (CO) and cardiac index (CI), and stroke volume (SV) and stroke volume index (SVI) based on heart rate. The NICOM technology will be implemented by the Rapid Response Team providers (Advanced Practice Providers) and ICU nurses at FSH, most of whom are already trained and familiar with its use.
Sponsors & Collaborators
- lead OTHER
Principal Investigators
-
Jeffrey Dichter, MD · University of Minnesota
Study Design
- Allocation
- NA
- Purpose
- SUPPORTIVE_CARE
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2023-07-31
- Primary Completion
- 2025-05-31
- Completion
- 2025-05-31
Countries
- United States
Study Locations
More Related Trials
-
Cardiac Output Monitoring in Burn Patients
NCT02404597 ·Status: WITHDRAWN ·Phase: NA
-
The Use of the Fluid IV Alert Monitor to Decrease the Incidence of Undetected Empty IV Bag in Dimmed Operating Rooms
NCT02666027 ·Status: COMPLETED ·Phase: NA
-
Measuring Cardiac Output and Stroke Volume Using the Physioflow Impedance Device in Pregnant Patients
NCT00573274 ·Status: COMPLETED
-
Assessment of Stroke Volume and Cardiac Output in Response to Varying Heart Rates
NCT03446326 ·Status: RECRUITING ·Phase: NA
-
Noninvasive Intracranial Pressure and Hydrocephalus Patients
NCT02404740 ·Status: COMPLETED
-
Effects of Blood Flow of Venoarterial Extracorporeal Membrane Oxygenation Life Support on Microcirculation
NCT03210818 ·Status: COMPLETED
-
Left Ventricular Outflow Tract Mean Velocity in Children: a Strong Alternative to Cardiac Index in Pediatric Intensive Care Unit
NCT06837727 ·Status: COMPLETED
-
Measurement of Cardiac Output and Intravascular Volume Status in Children Using COstatus (SH)
NCT01613859 ·Status: COMPLETED
-
Microcirculation in Venoarterial Extracorporeal Membrane Oxygenation Life Support
NCT02393274 ·Status: COMPLETED
-
Non-invasive Technology for Early Signal Detection of Hypoxemia With ORI During Intubation
NCT03600181 ·Status: COMPLETED
-
Mechanical Cardiopulmonary Resuscitation During Treatment of Acute Respiratory Failure Through Extracorporeal Membrane Oxygenation.
NCT05342363 ·Status: COMPLETED
-
Hemoperfusion in Extracorporeal Membrane Oxygenation (ECMO) Patients
NCT03729765 ·Status: RECRUITING ·Phase: NA
-
Role of HVNI in Severe Chest Trauma
NCT05692076 ·Status: UNKNOWN ·Phase: NA
-
Recirculation, Oxygenator Blood Volume and Cardiac Output Measurements During Extracorporeal Membrane Oxygenation
NCT00920569 ·Status: TERMINATED
-
Non Invasive Neuromonitoring After Cardiac Arrest
NCT02575196 ·Status: COMPLETED
-
PRECISION-CPR: PRecision-Controlled Ventilation in CPR
NCT07088120 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Waveform Capnography Compared to Colorimetric Carbon Dioxide Detection During Tracheal Intubation of Critically Ill Adults
NCT06934876 ·Status: RECRUITING
-
The Impact of Real Time Ventilation Feedback on Ventilation Rate and Tidal Volume During Cardiac Arrest.
NCT06528704 ·Status: RECRUITING ·Phase: NA
-
Servo Controlled Oxygen Targeting (SCO2T) Study: Masimo vs. Nellcor
NCT04866342 ·Status: COMPLETED ·Phase: NA
-
Study of Non-Invasive Regional Oxygen Saturations in Pediatric Patients Undergoing Cardiac Catheterization
NCT00939224 ·Status: COMPLETED
-
FIO2 Influences Accuracy of Fick-based Cardiac Output
NCT03970980 ·Status: COMPLETED ·Phase: NA
-
Correlation Between Changes in End-Tidal Carbon Dioxide and Stroke Volume Variation Detected by Electrical Cardiometry as A Predictor of Fluid Volume Responsiveness in Hemodynamically Unstable Patients in the Intensive Care
NCT03932617 ·Status: COMPLETED
-
PDA Occlusion Using NIRS
NCT06359522 ·Status: RECRUITING ·Phase: NA
-
Cerebral Oximetry in Single Lung Ventilation Thoracic Surgery
NCT01866657 ·Status: TERMINATED ·Phase: NA
-
Oxygen Saturation Alarms in the Neonatal Intensive Care Unit
NCT01085539 ·Status: COMPLETED