EXCOR Active Driving System for the EXCOR Pediatric VAD IDE Study
NCT05610787 · Status: ENROLLING_BY_INVITATION · Phase: NA · Type: INTERVENTIONAL · Enrollment: 40
Last updated 2026-03-04
Summary
The purpose of this study is to evaluate the device performance and monitor the safety and effectiveness of the Berlin Heart EXCOR Active Driving System while being used with the approved EXCOR Pediatric Ventricular Assist Device.
EXCOR Active Driving System is intended for use with the approved EXCOR Pediatric VAD.
The EXCOR Pediatric VAD is intended to provide mechanical circulatory support as a bridge to cardiac transplantation for pediatric patients. Pediatric candidates with severe isolated left ventricular or biventricular dysfunction who are candidates for cardiac transplant and require circulatory support may be treated using the EXCOR Pediatric.
EXCOR Active is intended for use in a clinical setting. EXCOR Active can be used in any kind of hospital unit (e.g. OR, ICU, intermediate care unit or general care unit). The driving unit may be moved between clinical units using the caddy or baby buggy; however, a patient must always be accompanied by a person trained in the use of the manual pump and emergency procedures during transport in the event of an emergency.
The driving unit can be transported during operation.
Conditions
- Heart Failure
- Transplant; Failure, Heart
- Congenital Heart Disease
Interventions
- DEVICE
-
EXCOR Active Driving System for Pediatric VAD
The EXCOR Active Driving System - will be used with the EXCOR Pediatric VAD.
Sponsors & Collaborators
-
Berlin Heart, Inc
lead INDUSTRY
Study Design
- Allocation
- NON_RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Max Age
- 21 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2022-11-14
- Primary Completion
- 2023-11-10
- Completion
- 2027-01-31
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
VentrAssistTM LVAD for the Treatment of Advanced Heart Failure - Destination Therapy
NCT00490321 ·Status: UNKNOWN ·Phase: PHASE3
-
CorMatrix Cor TRICUSPID ECM Valve Replacement Study
NCT02397668 ·Status: RECRUITING ·Phase: NA
-
DuoCor 2 DOMINATE Study
NCT07233876 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Evaluation of the HeartWare Left Ventricular Assist Device for the Treatment of Advanced Heart Failure
NCT00751972 ·Status: COMPLETED ·Phase: NA
-
A Feasibility Study of the CroíValve DUO System for Tricuspid Regurgitation
NCT05296148 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
PCORI-1310-06998 Trial of a Decision Support Intervention for Patients and Caregivers Offered Destination Therapy Heart Assist Device
NCT02344576 ·Status: COMPLETED ·Phase: NA
-
Veno-arterial Extracorporeal Membrane Oxygenation Prior to Left Ventricular Assist Device Implantation.
NCT03583970 ·Status: UNKNOWN
-
VentrAssistTM LVAD as a Bridge to Cardiac Transplantation - Feasibility Trial
NCT00490347 ·Status: COMPLETED ·Phase: PHASE2
-
Early Versus Emergency Left Ventricular Assist Device Implantation in Patients Awaiting Cardiac Transplantation
NCT02387112 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Corheart 6 LVAS Study
NCT05876000 ·Status: RECRUITING ·Phase: NA
-
Clinical Safety and Efficacy of the VDyne Transcatheter Tricuspid Valve Replacement System for the Treatment of Tricuspid Regurgitation
NCT05797519 ·Status: RECRUITING ·Phase: NA
-
Cardiac Resynchronization Therapy in Congenital Heart Diseases With Systemic Right Ventricle
NCT04842851 ·Status: COMPLETED
-
Evaluate the Safety and Performance of the AccuCinch® Ventricular Repair System - The CorCinch-EU Study
NCT03183895 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
CorMatrix Cor TRICUSPID ECM Valve Replacement - Pivotal Study
NCT05742906 ·Status: RECRUITING ·Phase: NA
-
Prospective Study of the BioVentrix PliCath HF™ System for the Treatment of Ischemic Cardiomyopathy
NCT01568138 ·Status: COMPLETED ·Phase: NA
-
Safety and Efficacy Study of the BioVentrix PliCath HF System
NCT01568164 ·Status: COMPLETED ·Phase: NA
-
HOPE at Heart (HOPE) of Donor Hearts After Circulatory Death (DCD) Using the XVIVO Heart Assist Transport System.
NCT06485596 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Clinical Trial to Evaluate the the ReliantHeart HeartAssist 5® VAD System in Patients Awaiting Heart Transplantation
NCT02205411 ·Status: TERMINATED ·Phase: NA
-
Levacor™ Ventricular Assist Device (VAD) Bridge to Transplant Study
NCT01001793 ·Status: TERMINATED ·Phase: NA
-
Registry for Cardiogenic Shock: Utility and Efficacy of Device Therapy
NCT02790242 ·Status: TERMINATED
-
Evaluating Edge-to-edge Transcatheter Tricuspid Valve Repair in Patients With Severe Symptomatic Tricuspid Regurgitation
NCT05628779 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Early Feasibility Evaluation of the AccuCinch® Ventricular Restoration System in Patients With Heart Failure and Reduced Ejection Fraction
NCT03533517 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
EFS of the DUO System for Tricuspid Regurgitation
NCT05913908 ·Status: RECRUITING ·Phase: NA
-
Clinical Trial of Ventiflow LP Supporting High-risk Percutaneous Coronary Intervention(PCI)
NCT06754839 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
REDUCE LAP-HF III Corvia Protocol 1701
NCT03191656 ·Status: ACTIVE_NOT_RECRUITING