Small-diameter Closed Thoracic Drainage Tube Fixation Method

NCT05601076 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 139

Last updated 2022-11-01

No results posted yet for this study

Summary

Objective: To explore the design feasibility and application effect of triple-buffer-system-fixed small-diameter (18 F) thoracic closed drainage tubes following lung wedge resection. Methods: A total of 136 patients with indwelling thoracic drainage tubes following pulmonary wedge resection were recruited, with 70 patients allocated to the control group and 66 to the experimental group. The drainage tube in the experimental group was fixed with the triple-buffer system, while that in the control group was fixed using the conventional lifting platform method. The incidence of unplanned extubation, the indwelling time of the drainage tube and the time and material costs, as well as information regarding any subcutaneous emphysema and skin tension blisters, were recorded following the operation. The pain and degree of comfort were assessed using a chi-square test and a rank sum t-test to compare the differences between the two groups.

Conditions

  • Pulmonary Wedge Resection

Interventions

PROCEDURE

fixed with the triple-buffer system

The steps were as follows: i) elastic cotton tape (3M 2733-25 Japan Ltd., Tokyo, Japan) was used at the proximal 15 cm from the incision, with 5 × 2.5 cm pieces glued to the skin and fixed with the drainage tube using surgical knots; ii) the distal end of the ligation was fixed using the same method, while the ligation position was higher than the first; iii) the ligature point was fixed next to the elastic soft cotton tape (5 × 5 cm), using the high-platform method to fix the drainage tube, with the drainage tube curved; and iv) the drainage tube between the two fixed points was inserted with a specific radian.

PROCEDURE

fixed using the conventional lifting platform method

In terms of the control group, two lines of flexible cotton tape (3M 2733-25 Japan Ltd., Tokyo, Japan) measuring 10 × 2.5 cm were used, and the drainage tube was fixed parallel to the long axis and glued to the middle-position 360° winding tube once the drainage tube was 0.5 cm higher than the surrounding skin. Next, the drainage tube was fixed at both ends to the patient's skin using adhesive tape. Then, the tube and the adhesive plaster were overlapped vertically and horizontally, the tube was inserted, the adhesive plaster was added, and then the chest tube was fixed on the adhesive plaster by knotting the interspersed cotton rope, which was equal to indirectly fixing the tube on the patient's skin

Sponsors & Collaborators

  • Taizhou Hospital of Zhejiang Province affiliated to Wenzhou Medical University

    lead OTHER

Principal Investigators

  • Caifang Yang, Dr. · Taizhou Hospital of Zhejiang Province affiliated to Wenzhou Medical University

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Model
PARALLEL

Eligibility

Sex
ALL
Healthy Volunteers
Yes

Timeline & Regulatory

Start
2019-02-02
Primary Completion
2021-08-30
Completion
2022-07-30

Countries

  • China

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT05601076 on ClinicalTrials.gov