Endothelial Cell Loss in Pseudophakic Patients Receiving a Paul Glaucoma Drainage Device With Its Tube Inserted in the Anterior Versus Posterior Chamber: a Randomized Controlled Trial
NCT05500469 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 200
Last updated 2022-12-13
Summary
Rationale: Glaucoma is a group of diseases characterized by progressive neuropathy of the optic nerve associated with visual field loss. Current glaucoma management aims to preserve visual function throughout life by reducing the intraocular pressure. This can be achieved by medical therapy or by surgical procedures such as implantation of a glaucoma drainage device (GDD). Conventionally, the tube of such a device is positioned in the anterior chamber (AC). Unfortunately, the presence of the tube in the AC may have a significant negative impact on the number of endothelial cells of the cornea and may even lead to corneal decompensation. Alternatively, the tube can be positioned in the posterior chamber (i.e. behind the iris). In this study, both procedures will be compared.
Objective: Primary: to determine the loss of corneal endothelial cells after implantation of a Paul GDD with its tube either anterior or posterior of the iris. Secondary: to compare efficacy and safety of both procedures.
Study design: Prospective, randomised, treatment controlled clinical trial. Study population: Pseudophakic patients with glaucoma who need a GDD. Intervention: Implantation of a Paul GDD with its tube anterior/posterior of the iris. Main study parameters/endpoints: Endothelial cell loss of the cornea.
Nature and extent of the burden and risks associated with participation, benefit and group relatedness: At present potential benefits and drawbacks of positioning the Paul tube behind the iris are insufficiently known, successful positioning of the tube may require slightly more surgery time and the risk of hyphaema may be higher. It is expected, that in the long run damage to the corneal endothelium is less. Risks of study-related assessments are negligible, burden is low, extra time is about 35+15+35+35 minutes (total 2h).
Conditions
Interventions
- DEVICE
-
Paul glaucoma drainage device (GDD)
Implantation of the GDD
Sponsors & Collaborators
-
Oogziekenhuis Rotterdam
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 100 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2022-10-20
- Primary Completion
- 2026-08-31
- Completion
- 2026-08-31
Countries
- Netherlands
Study Locations
More Related Trials
-
Treatment Outcomes of a Novel Glaucoma Tube Shunt Implant for Intraocular Pressure Control in Eyes With Refractory Glaucoma
NCT04297930 ·Status: COMPLETED
-
Efficacy and Safety of Posterior Chamber Glaucoma Drainage Device
NCT07003685 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Evaluation of the iStent Versus Two Ocular Hypotensive Agents in Patients With Primary Open-angle Glaucoma (POAG)
NCT00913029 ·Status: COMPLETED ·Phase: PHASE4
-
5 Years Long Term Results After Standalone CyPass-Implantation
NCT03114059 ·Status: COMPLETED
-
Phacoemulsification vs SLT as Initial Treatment for Pseudoexfoliation Glaucoma
NCT04416724 ·Status: RECRUITING ·Phase: NA
-
Direct Selective Laser Trabeculoplasty (DSLT) for Reducing Eye Pressure in Non-Caucasian Patients With Open Angle Glaucoma
NCT07147647 ·Status: RECRUITING ·Phase: NA
-
Advanced Glaucoma Progression Study
NCT01742819 ·Status: ACTIVE_NOT_RECRUITING
-
Pilot Clinical Trial on a New Adjustable Glaucoma Drainage Device
NCT02554214 ·Status: UNKNOWN ·Phase: NA
-
A Comparison of Two Ab Interno Procedures in the Treatment of Glaucoma in Patients Undergoing Cataract Extraction
NCT02784249 ·Status: COMPLETED ·Phase: NA
-
Alcon® Ex-PRESS® Glaucoma Filtration Device in Japanese Patients
NCT02246777 ·Status: COMPLETED ·Phase: NA
-
Efficacy of Selective Laser Trabeculoplasty in Pseudophakic Patients
NCT01467388 ·Status: UNKNOWN
-
Changes of the Peripapillary Retinal Nerve Fiber Layer After Filtration Surgery in Glaucoma Patients
NCT01422525 ·Status: TERMINATED
-
Changes in Ocular Rigidity After Trabeculectomy in Patients With POAG
NCT02544646 ·Status: COMPLETED ·Phase: NA
-
Different Glaucoma Treatments Effect on Intraocular Pressure Fluctuation With Postural Change in Eyes With Open-angle Glaucoma
NCT02868502 ·Status: UNKNOWN
-
Study Comparing the Kinetics of Endothelial Cell Loss Associated With the XEN® Implant Versus Traditional Filtering Surgery for Glaucoma
NCT04781283 ·Status: WITHDRAWN ·Phase: NA
-
Efficacy of Selective Laser Trabeculoplasty in Patients Under Treatment With Topical Prostaglandines
NCT01467440 ·Status: UNKNOWN
-
Prophylactic Peripheral Iridectomy Prevents Aphakic Angle-closure Glaucoma
NCT03610295 ·Status: COMPLETED ·Phase: NA
-
Multicenter Glaucoma Study Investigating Standalone Canaloplasty
NCT05786196 ·Status: RECRUITING ·Phase: NA
-
Minimally Invasive Suprachoroidal Drainage for the Treatment of Neovascular Glaucoma
NCT07201415 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Are There Changes in the Nerve Fiber Layer (NFL) After Lowering of Eye Pressure?
NCT02600403 ·Status: COMPLETED
-
The Effect of Body Posture on Intraocular Pressure in Progressive Glaucoma
NCT01351779 ·Status: UNKNOWN
-
Novel Drug Delivery Technique Via Retroject Device
NCT02051946 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
Reliability and Reproducibility of the Eye Check Tonometer
NCT04639947 ·Status: TERMINATED ·Phase: NA
-
The Effect of Trabeculectomy & Ex-PRESS Glaucoma Drainage Implant on the Corneal Biomechanical Properties
NCT04648943 ·Status: COMPLETED ·Phase: NA
-
Comparative Study, Safety and Efficacy, Ahmed Glaucoma Drainage Device, Model M4 Model S2 in Neovascular Glaucoma
NCT02260219 ·Status: TERMINATED ·Phase: NA