Accuracy of CADx System for White Light Colonic Polyp Characterization
NCT05492656 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 500
Last updated 2024-03-26
Summary
The endoscopist performances in the optical diagnosis (OD) of colonic polyps with the available technologies vary widely across centers and across endoscopists. The OD process is strictly related to the operator training and expertise. Most of the available studies in optical characterization have been carried out by expert endoscopist in tertiary high volume centers, and weren't replied on large unselected populations. For these reasons, at the moment the optical characterization of polypoid lesions can't replace, in the everyday clinical practice, the histopathological evaluation of resected polyps. Artificial intelligence (AI)-based systems have the potential to make optical characterization process of colonic polyps easier and more reliable, thus supporting the endoscopist in the application of leave-in-situ and of resect-and-discard strategies. The implementation of such strategies would lead to a significant economic saving and a decrease of risks and complications related to unnecessary polypectomy. GI-Genius System (Medtronic Inc, Minneaopolis, USA) is a CNN-based algorithm allowing an automatic OD of colonic polyps. This system does not require dedicated light setting for polyp evaluation as it works with white light high definition images, which are the actual standard in every endoscopic unit. During colonoscopy, when a polyp is framed within the screen, a green detection box surrounds the polyp and the system automatically provides (whenever possible) the optical diagnosis labeling the polyp as "adenoma or non-adenoma". When the automatic polyp charaterization is unfeasible the label "no prediction" appears. Nowadays only few data about the feasibility and performances of this system in clinical practice are available. In addition published studies are mostly focused on technical rather thann clinical issues. The present prospective observational trial is primarily aimed at evaluating the diagnostic accuracy of optical characterization of colonic polyps \<= 1 cm using GI-Genius System in daily clinical practice, having histopathology examination as reference standard.
Conditions
- Colonic Polyp
- Adenoma Colon
Sponsors & Collaborators
-
Valduce Hospital
lead OTHER
Eligibility
- Min Age
- 18 Years
- Max Age
- 85 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2022-08-05
- Primary Completion
- 2022-11-05
- Completion
- 2022-11-05
Countries
- Italy
Study Locations
More Related Trials
-
Role of Computer-Aided Detection Colonoscopy in Polyp Detection Rate
NCT07171333 ·Status: COMPLETED ·Phase: NA
-
Optical Polyp Testing for In Vivo Classification
NCT03139942 ·Status: COMPLETED ·Phase: NA
-
The COMBO CAD Study
NCT05141409 ·Status: COMPLETED
-
Computer Assisted Optical Assessment of Small Colorectal Polyps
NCT02522702 ·Status: UNKNOWN
-
Computer-based Classification of Colorectal Polyps Using Narrow-band Imaging
NCT01262248 ·Status: COMPLETED
-
White Light vs Narrow Band Imagingin the Diagnosis of Right Sided Colonic Polyps in Asymptomatic Subjects Undergoing Screening Colonoscopy
NCT05935124 ·Status: RECRUITING ·Phase: NA
-
Discard:Characterisation of Colonic Polyps in Vivo
NCT00888771 ·Status: COMPLETED
-
Impact of Automatic Polyp Detection System on Adenoma Detection Rate
NCT03967756 ·Status: UNKNOWN ·Phase: NA
-
Accuracy in Resection of Non-pedunculated Colonic Lesions 5-20 mm With/Without Using NBI
NCT02641509 ·Status: TERMINATED ·Phase: NA
-
Detection and Classification of Colon Polyps
NCT00825292 ·Status: COMPLETED ·Phase: PHASE2
-
Endoscopic Size Assessment of Advanced Adenomatous Polyps
NCT02193646 ·Status: COMPLETED
-
Computer Assisted Measurement of Colorectal Polyps
NCT02970760 ·Status: UNKNOWN
-
Narrow Band Imaging in the Prediction of Surveillance Intervals After Polypectomy in Community Practice: Ready for (a European) Prime Time
NCT02196402 ·Status: COMPLETED
-
Computer Aided Diagnosis of Colorectal Neoplasms During Colonoscopic Examination
NCT03069833 ·Status: UNKNOWN ·Phase: NA
-
Colorectal Polyp Discrimination Using High-Definition Narrow Band Imaging
NCT01354873 ·Status: COMPLETED
-
TXI for the Recognition of Adenomas in Colonoscopy
NCT04892966 ·Status: COMPLETED ·Phase: NA
-
Assessing the Additional Neoplasia Yield of Computer-aided Colonoscopy in Follow-up Patients in a Screening Setting
NCT06160466 ·Status: COMPLETED ·Phase: NA
-
Acetic Acid for Optical Characterization of Colonic Polyps
NCT02760381 ·Status: UNKNOWN ·Phase: NA
-
Accuracy of Endoscopists in Predicting Polyp Pathology
NCT03477318 ·Status: COMPLETED
-
Impact of Computer-Aided Detection (CAD) as Second Reader in CT Colonography
NCT01399710 ·Status: COMPLETED ·Phase: PHASE3
-
Impact of Diverticular Disease on the Detection of Colon Adenomas
NCT02057562 ·Status: UNKNOWN
-
Precision of Optical Diagnosis in Polyps Between 5-15 mm and Its Implications on Surveillance. A Prospective, Multicenter Study.
NCT04232176 ·Status: COMPLETED
-
Blue Light Imaging (BLI) for Optical Diagnosis of Colorectal Polyps
NCT03746171 ·Status: COMPLETED
-
Practice-Based Learning to Predict Polyp Histology at Colonoscopy
NCT01638091 ·Status: COMPLETED ·Phase: NA
-
The Characterization of Small and Diminutive Colonic Polyps in LCI
NCT03351257 ·Status: UNKNOWN