Role of Computer-Aided Detection Colonoscopy in Polyp Detection Rate
NCT07171333 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 421
Last updated 2025-09-12
Summary
High-definition (HD) colonoscopy is the gold standard for early diagnosis and treatment of lower gastrointestinal neoplasms, with the adenoma detection rate (ADR) serving as a key quality indicator due to its inverse correlation with colorectal cancer incidence. ADR is influenced by operator expertise, fatigue, and human error, which may be mitigated by advanced imaging technologies such as computer-aided detection (CADe). CADe systems provide real-time visual and auditory alerts for suspected polyps and have been shown to increase ADR, though their effectiveness under different operator conditions (high- vs. low-volume, fatigue-related performance, impact on polyp detection rate \[PDR\] and withdrawal time) remains unclear. This multicenter, prospective, national, open-label randomized trial (6 Italian centers) will compare HD-Iscan colonoscopy with and without CADe assistance (1:1 allocation), with primary endpoint ADR and secondary endpoints including PDR, withdrawal time, and performance stratified by operator fatigue. Eligible patients (aged 40-80, undergoing screening, surveillance, or diagnostic colonoscopy) will be recruited consecutively, with exclusions for prior colonic resection, recent diverticulitis, inflammatory bowel disease, familial polyposis, inadequate bowel preparation, complete colonoscopy within 5 years, inability to consent, or unsafe ongoing antithrombotic therapy. Colonoscopies will follow ESGE guidelines with standard split-dose PEG preparation; all polyps will be resected and documented. Operator allocation to high- (≥200 colonoscopies/year) or low-volume (\<200/year) groups will follow routine clinical scheduling, with stratified analyses performed. The trial involves no investigational drugs or additional invasive procedures, and no adverse events are anticipated beyond those inherent to colonoscopy.
Conditions
- Colorectal Polyps
Interventions
- DEVICE
-
Colonoscopy with CADe system
Patients in the CADe+ arm underwent colonoscopy with CADe DISCOVERY™ (PENTAX Medical, Tokyo, Japan), an AI-driven tool highlighting suspected lesions in real-time, through a light-blue box. The final lesion characterization remained the endoscopist's responsibility.
Sponsors & Collaborators
-
Pentax Medical
collaborator INDUSTRY -
Gian Eugenio Tontini
lead OTHER
Principal Investigators
-
Gian Eugenio Tontini, MD, PhD · Fondazione IRCCS Ca' Granda, Ospedale Maggiore Policlinico
Study Design
- Allocation
- RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 40 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2023-08-01
- Primary Completion
- 2024-09-30
- Completion
- 2024-09-30
Countries
- Italy
Study Locations
More Related Trials
-
Efficacy of CAD in Screening Colonoscopy to Reduce the Risk of Advanced Adenoma at 3 Years.
NCT07299071 ·Status: RECRUITING ·Phase: NA
-
Adenoma Detection Rate of 3D Colonoscopy
NCT05153746 ·Status: COMPLETED ·Phase: NA
-
Detection and Classification of Colon Polyps
NCT00825292 ·Status: COMPLETED ·Phase: PHASE2
-
Inspection of the Colon Using a Retrograde Viewing Device for Detection of Colorectal Polyps
NCT04107376 ·Status: UNKNOWN ·Phase: NA
-
Synergistic Effect of G-Eye Balloon for Behind the Folds Visualization With CADe (Discovery System) on Adenoma Detection Rate.
NCT05220345 ·Status: COMPLETED ·Phase: NA
-
Assessing the Additional Neoplasia Yield of Computer-aided Colonoscopy in Follow-up Patients in a Screening Setting
NCT06160466 ·Status: COMPLETED ·Phase: NA
-
Computer Assisted Measurement of Colorectal Polyps
NCT02970760 ·Status: UNKNOWN
-
Comparison of the Performance Between Conventional Colonoscopy and 3D Colonoscopy in Positive Fecal Immunochemical Test Group
NCT06678477 ·Status: RECRUITING ·Phase: NA
-
Panoramic Screening by Complete Colonoscopy in the Management of Colorectal Adenomas
NCT03961893 ·Status: COMPLETED ·Phase: NA
-
Optical Polyp Testing for In Vivo Classification
NCT03139942 ·Status: COMPLETED ·Phase: NA
-
Adenoma Detection Rate With Endocuff-Assisted Colonoscopy - an Italian Trial
NCT03612674 ·Status: UNKNOWN ·Phase: NA
-
High Definition Endoscopy With i-Scan for Small Colonic Polyp Evaluation: The HiScope Study
NCT01761279 ·Status: COMPLETED
-
High Definition Endoscopy and Virtual Chromoendoscopy Versus Standard Resolution Endoscopy in Detection of Colon Polyps
NCT03243669 ·Status: COMPLETED ·Phase: NA
-
Computer-aided Detection During Screening Colonoscopy
NCT05734820 ·Status: UNKNOWN ·Phase: NA
-
Endocuff Vision Assisted vs. Standard Polyp Resection in the Colorectum
NCT03117114 ·Status: COMPLETED ·Phase: NA
-
Computer Aided Diagnosis of Colorectal Polyps
NCT04510545 ·Status: COMPLETED
-
Computer Aided Diagnosis (CADx) for Colorectal Polyps Resect-and-Discard Strategy
NCT06062095 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Endoscopic Assessment of Polyp Histology
NCT01297712 ·Status: TERMINATED ·Phase: NA
-
Endocuff Adenoma Detection Rate Pilot Study
NCT01761097 ·Status: UNKNOWN ·Phase: NA
-
Computer Aided Detection, Tandem Colonoscopy Study
NCT04074577 ·Status: COMPLETED ·Phase: NA
-
Assessing the Additional Neoplasia Yield of Computer-aided Colonoscopy in a Screening Setting
NCT04441580 ·Status: COMPLETED ·Phase: NA
-
Japanese National Computed Tomographic (CT) Colonography Trial
NCT00997802 ·Status: COMPLETED ·Phase: NA
-
Retroview Colonoscope for the Evaluation of Colon Mucosa Study
NCT02352233 ·Status: COMPLETED
-
Can Pan-Colonic Chromoendoscopy (PCC) Improve Adenoma Detection Rate in FIT-Positive-Patients: A Randomized Study
NCT04512612 ·Status: UNKNOWN ·Phase: NA
-
Impact of Automatic Polyp Detection System on Adenoma Detection Rate
NCT03967756 ·Status: UNKNOWN ·Phase: NA