Respiration Validation for CPM Device
NCT05445492 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 41
Last updated 2024-06-12
Summary
This study is designed to be a clinical validation study to ready the CPM System for FDA 510(k) submission. This study will be conducted as a prospective non-randomized. The study is non-significant risk since the CPM Device is noninterventional and noninvasive. The study is primarily designed to validate the accuracy of the respiration rate and the changes in relative tidal volume. All participants will be fitted with both the CPM Device as well as reference devices (capnography and ECG). Participants will be randomized between 4 procedures (A-D) which will determine the order of 10 exercises. Each exercise has about 2 minutes of device recording and two minutes of rest. Each exercise contains two positions: sitting up for one minute and lying down for one minute. For some exercises, the participant will be instructed to breathe at a certain rate (assisted by a metronome). For other exercises, the participants will breathe at a normal rate but change how deep the are breathing. For the last, all capnography reference devices will be removed, and an ECG reference device will be placed. After exercise 18, the participant will have all devices removed and the study visit will terminate. The participant will receive a safety follow-up call about 1 week after their visit.
Conditions
- Cardiopulmonary Disease
Interventions
- DEVICE
-
CPM Device
The CPM device and reference device are used simultaneous to validate the CPM device.
Sponsors & Collaborators
-
Clayton Sleep Insititute
collaborator INDUSTRY -
Analog Device, Inc.
lead OTHER
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2022-06-22
- Primary Completion
- 2022-08-04
- Completion
- 2022-08-11
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Randomized Study of the pdSTIM™ System in Failure to Wean Mechanically Ventilated Patients
NCT05998018 ·Status: TERMINATED ·Phase: NA
-
Real World Assessment of Resistance Breathing Device
NCT07187349 ·Status: COMPLETED
-
Effect of Early Extracorporeal Diaphragm Pacing Combined With Tilt Table in Ventilated Patients.
NCT05953649 ·Status: UNKNOWN ·Phase: NA
-
Automatic Detection of Dyspnea in Mechanically Ventilated, Critically Ill Patients
NCT07205952 ·Status: RECRUITING
-
Non-invasive Ventilation in Severe Chronic Obstructive Pulmonary Disease(COPD)
NCT00710541 ·Status: TERMINATED ·Phase: NA
-
Cross-over Comparison of the V60 System to Other Bi-Level Noninvasive Ventilators
NCT00817297 ·Status: COMPLETED ·Phase: NA
-
Physiological Effects of Continuous Negative External Pressure for Acute Hypoxemic Respiratory Failure
NCT05675345 ·Status: RECRUITING ·Phase: NA
-
Multisystem and Autonomic Complications of NMD on Long-term NIV
NCT04100993 ·Status: COMPLETED
-
Assessment of Volume-targeted Ventilation in Patients With Neuromuscular Disease
NCT06339580 ·Status: RECRUITING ·Phase: PHASE2
-
Ability of Caregivers to Provide Ventilation With the SAVe Resuscitator in a Model
NCT01477710 ·Status: COMPLETED ·Phase: NA
-
Deventilation Dyspnea in COPD Patients Using NIV
NCT03503123 ·Status: COMPLETED
-
Non-invasive Respiratory Monitoring During SBT
NCT05295186 ·Status: COMPLETED
-
Evaluation of Prolonged Apnea Supported by High Frequency Non-invasive Ventilation.
NCT02712190 ·Status: UNKNOWN ·Phase: NA
-
Predictors of Upper Airway Function and Sleep-disordered Breathing in the Critically Ill
NCT02112604 ·Status: UNKNOWN
-
Efficacy and Safety of Dexmedetomidine During Non-Invasive Positive Pressure Ventilation
NCT00871624 ·Status: COMPLETED ·Phase: PHASE2
-
Diaphragm Protective Ventilation in the Intensive Care Unit
NCT03527797 ·Status: COMPLETED ·Phase: NA
-
Unloading Respiratory Muscles During NIV: Comparison of a Spontaneous and Auto-adjusting Controlled Mode
NCT00366912 ·Status: TERMINATED ·Phase: NA
-
Peripheral Nerve Stimulation to Reduce Hypoxic Events
NCT02554110 ·Status: COMPLETED ·Phase: NA
-
Non-invasive Ventilation Versus Sham Ventilation in Chronic Obstructive Pulmonary Disease (COPD)
NCT00429156 ·Status: COMPLETED ·Phase: PHASE3
-
Impact of PAV Versus NAVA on Patient-Ventilator Synchrony and Respiratory Muscle Unloading
NCT01810510 ·Status: WITHDRAWN ·Phase: NA
-
Patient-Ventilator Interactions in Chronic Obstructive Pulmonary Diseases (COPD) Under Non-Invasive Ventilation
NCT01180439 ·Status: COMPLETED ·Phase: NA
-
Measuring Sedation in the Intensive Care Unit Using Wireless Accelerometers
NCT02529696 ·Status: TERMINATED
-
Perminova Respiratory Effort Accuracy Validation 09-12-2013-Rev 2
NCT02048436 ·Status: COMPLETED
-
Patient-ventilator Interactions in Long Term Non-invasive Ventilation: Influence of Back-up Frequency
NCT01130090 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Oxygen Consumption and Energy Expenditure During Spontaneous Breathing Trial.
NCT01757093 ·Status: COMPLETED ·Phase: NA