Dreaming During Anesthesia and Anesthetic Depth in Elective Surgery Patients Under General Anesthesia
NCT05357872 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 100
Last updated 2022-05-03
Summary
Dreaming is a common, enduring, and fascinating part of the anesthetic experience, but its cause and timing remain elusive. Patients typically report that they were dreaming during anesthesia, but the actual timing of anesthetic dreaming is unknown. The following evidence supports the hypothesis that dreaming occurs intraoperatively and is related to light or inadequate anesthesia: (1) The incidence of dreaming has decreased as anesthetic techniques have improved; (2) dreamers exhibit more clinical signs of light anesthesia or report more awareness than non dreamers; (3) dreamers may receive lower doses of anesthetic drugs than non dreamers and emerge more rapidly from anesthesia; (4) the content of dreams may involve surgical topics or events occurring during anesthesia; and (5) in one study, the incidence of dreaming was lower in Bispectral Index (BIS)-monitored patients. Alternatively, dreaming may occur during emergence from anesthesia, when the brain is still affected by sedative concentrations of anesthetic drugs and the patient enters a sleep state. Few studies have assessed the relation between dreaming and depth of anesthesia, and their results were inconclusive.Most recently, in the B-Aware Trial, no differences in depth of anesthesia, as measured by BIS, were detected between dreamers and non dreamers. However, the patients were at high risk of awareness, and BIS data were collected manually and were only recorded in the BIS group and during maintenance. No studies investigating the relation between dreaming and depth of anesthesia during recovery were identified. Why is the investigation of dreaming during anesthesia important? Dreaming is one of the most common side effects of anesthesia but remains puzzling and requires explanation. Dreaming is sometimes distressing to patients and may decrease satisfaction with care. Some patients who report dreaming fear that their anesthetic was inadequate and that their experience was, in fact, awareness. Indeed, in a minority of cases, dreaming may truly represent near-miss awareness. The investigators therefore tested the hypothesis that dreaming during anesthesia is associated with light or inadequate anesthesia, as evidenced by higher median BIS values during maintenance of anesthesia. The investigators also explored the depth of anesthesia until emergence, the form and content of dreams, the predictors of dreaming during anesthesia, and the effect of dreaming on quality of recovery and satisfaction with anesthetic care
Conditions
- Dreaming
- General Anesthesia
Interventions
- DEVICE
-
deep anesthesia depth
The anesthesiologist adjusted the intravenous speed of remifentanil and propofol to maintain the bispectral index (BIS, BIS monitor; Aspect Medical System, Newton, MA) between 40-50 and 50-60 during the operation.
- DEVICE
-
light anesthesia depth
The anesthesiologist adjusted the intravenous speed of remifentanil and propofol to maintain the bispectral index (BIS, BIS monitor; Aspect Medical System, Newton, MA) between 40-50 and 50-60 during the operation.
Sponsors & Collaborators
-
Shengjing Hospital
lead OTHER
Principal Investigators
-
junchao zhu · Shengjing Hospital
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- QUADRUPLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 70 Years
- Sex
- FEMALE
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2021-12-01
- Primary Completion
- 2022-06-30
- Completion
- 2022-07-31
Countries
- China
Study Locations
More Related Trials
-
Preoperative Anxiety on Postoperative Outcome and Sleep Quality in Patients Undergoing Laparoscopic Hysterectomy
NCT04619979 ·Status: COMPLETED
-
Effect of Depth of Total Intravenous Anesthesia Using Propofol on Postoperative Cognitive Dysfunction
NCT01708837 ·Status: UNKNOWN ·Phase: PHASE4
-
Preoperative Anxiety Level, Premedications and General Anaesthetic Proceedings
NCT03603873 ·Status: COMPLETED
-
Influence of Different Anesthetic Procedures on Sleep Disorder Breathing
NCT03499132 ·Status: COMPLETED
-
The Effect of General Anesthesia with Remimazolam and Propofol on Rhythmic State and Cognitive Function
NCT06775366 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Consciousness-specific Brain Network Connection of Propofol Sedation and Prolonged Disorders of Consciousness
NCT05823454 ·Status: RECRUITING
-
An Observer Rating Scale of Facial Expression Can Predict Dreaming in Propofol Anesthesia
NCT04235894 ·Status: COMPLETED
-
Dreaming and EEG Changes During Anaesthesia Maintained With Propofol or Desflurane
NCT00446212 ·Status: COMPLETED ·Phase: PHASE4
-
Effect of Propofol on Postoperative Sleep Quality in Elderly Patients With Sleep Disorders
NCT05325762 ·Status: UNKNOWN ·Phase: PHASE4
-
Analysis of Autonomic Function During Anesthesia Using Response Surface Model
NCT03072069 ·Status: COMPLETED
-
Depth of Anesthesia on Implicit Memory
NCT00584324 ·Status: COMPLETED ·Phase: NA
-
Electro-acupuncture and Flumazenil's Effect on Sedation
NCT02690389 ·Status: COMPLETED ·Phase: NA
-
Brain Network Analysis of Anesthesia Characteristics in Patients With pDoC Based on PSG
NCT06157008 ·Status: RECRUITING
-
Effects of Volatile Anaesthetics on Incidence of Postoperative Depression and Anxiety in Elderly Patients
NCT06307717 ·Status: COMPLETED
-
Postoperative Sleep Quality in Patients Undergoing Thoracic Surgery With Different Types of Anesthesia Management
NCT01725607 ·Status: COMPLETED ·Phase: PHASE4
-
A Study of the Correlation Between the Debilitating State of the Elderly and Propofol Sensitivity
NCT06870357 ·Status: COMPLETED ·Phase: EARLY_PHASE1
-
The Effect of a Reduced Noise Environment on the Response Time of the Anesthesia Provider
NCT03507855 ·Status: COMPLETED ·Phase: NA
-
Using Preoperative Anxiety Score to Determine the Precise Dose of Butorphanol for Sedation
NCT03429179 ·Status: COMPLETED ·Phase: PHASE2
-
Characterizing the Electroencephalogram Signature of Fentanyl During Induction of General Anesthesia
NCT03866278 ·Status: COMPLETED
-
Study on the Influencing Factors of Electroencephalogram Parameters Under Anesthesia
NCT04760028 ·Status: COMPLETED ·Phase: PHASE4
-
Cognitive Effects of Inhalational Versus Intravenous General Anesthesia in the Elderly
NCT00788008 ·Status: COMPLETED ·Phase: NA
-
Anesthetic Management of Patients With Chronic Sleep Disorders
NCT04827329 ·Status: COMPLETED
-
The Effects of Two Induction Means on Emergence After General Anesthesia
NCT02974712 ·Status: UNKNOWN ·Phase: NA
-
Changes in Cerebral Oxygenation During Deliberate Hypotensive Anesthesia
NCT00207987 ·Status: UNKNOWN
-
Memory During Anesthesia: the Role of Stress Hormones
NCT01146405 ·Status: UNKNOWN