Stent Implantation of Polyurethane Expandable Valve, by Catheter, in Patients With Pulmonary Valve Dysfunction
NCT05289622 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 5
Last updated 2022-04-01
Summary
Prospective Study, Single Arm to evaluate the safety and efficacy of polyurethane expandable valve implantation in the pulmonary position, in 5 patients over 18 years of age, with pulmonary valve dysfunction and moderate to severe impairment of Right Ventricular function. During throughout the study, safety parameters related to valve operation will be evaluated (patient's Functional Class), in addition to the occurrence of Serious Adverse Events. After the procedure, the patient must be hospitalized in the Intensive Care Unit until the complete hemodynamic stabilization and normalization of lung function and in good general condition (2 to 3 days of stay) and then transferred to the ward (2 to 3 days and stay) before hospital discharge. A formal Statistical Analysis Plan (SAP) will be developed and finalized before closing the database. Full details of data presentations and analysis will be provided in SAP.
Additional statistical analyses, other than those described in this section, may be performed if deemed appropriate and included in SAP. Any deviations from the final analysis plan or what is presented in the protocol will be discussed in the final study report. No formal inferential statistics will be applied to the data collected in the study.
Conditions
- Valvulopathy
Interventions
- DEVICE
-
Polyurethane expandable valve stent implant
The baseline assessment of patients will include the admission of patients and the performance of preoperative exams (cardiological imaging for the correct selection). An estimated surgery time of 5 hours. During the entire procedure, patients will be under general anesthesia and controlled mechanical ventilation. The material collected in the laboratory will be processed, the result released and discarded. After the patient enters the operating room, hemodynamic monitoring, ECG, arterial saturation, with peripheral sensor, central venous access with double lumen catheter will be carried out; blood pressure monitoring by radial artery puncture, bladder catheter and thermometer in the nasopharynx and rectum. After preoperative preparation, patients will undergo a surgical approach by median thoracotomy and installation of the Cardiopulmonary bypass (ECC) circuit, by placing a cannula in the ascending aorta, Superior Vena Cava (SVC) and Inferior Vena Cava (IVC).
Sponsors & Collaborators
-
SYNTHETIC HEART TECHNOLOGY
collaborator UNKNOWN -
Dr. Miguel Angel Maluf
lead OTHER
Principal Investigators
-
Miguel Angel Maluf · Hospital Alemão Oswaldo Cruz
Study Design
- Allocation
- NA
- Purpose
- DEVICE_FEASIBILITY
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2022-10-31
- Primary Completion
- 2022-12-31
- Completion
- 2023-02-28
- FDA Device
- Yes
Countries
- Brazil
Study Locations
More Related Trials
-
Aortic Root Enlargement in Aortic Valve Replacement
NCT03603483 ·Status: UNKNOWN ·Phase: NA
-
Evaluating the Safety and Efficacy of Prosthetic Polymer Heart Valves for the Treatment of Aortic Valve Disease
NCT06518681 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Swartz Sheath With Angioplasty Guidewire-Assisted Technique for Patent Foramen Ovale Closure (STAGE-PFO)
NCT06793969 ·Status: RECRUITING ·Phase: NA
-
5 Year Observation of Patients With PORTICO Valves
NCT01802788 ·Status: COMPLETED
-
Portico TAVI Implant With Transfemoral Delivery System
NCT01493284 ·Status: COMPLETED ·Phase: NA
-
Perioperative Hemodynamic and Microcirculatory Physiological Study During TAVI
NCT06154642 ·Status: COMPLETED
-
Evaluation of the Strategy of "One-stop" Endovascular Treatment for Concomitant Coronary Artery Disease and Aortic Atherosclerotic Disease
NCT03563768 ·Status: UNKNOWN ·Phase: PHASE4
-
Transcatheter Implantation of Aortic Bioprosthesis Without the Use of Iodinated Contrast in Patients With Chronic Kidney Disease
NCT04581694 ·Status: UNKNOWN ·Phase: NA
-
Performance of Currently Available traNscaTHEter Aortic Valve Platforms in Inoperable Patients With Pure Aortic regurgitatiON of a Native Valve. The PANTHEON International Project.
NCT05319171 ·Status: UNKNOWN
-
Evaluate Safety and Effectiveness of XenoSure Biological Patch in the Application of Cardiac Repair
NCT03176225 ·Status: COMPLETED ·Phase: NA
-
PERFECT - Portuguese Evolut Registry Studying the Outcomes of Medtronic Evolut™ FX+ TAVI System by Evaluating an Optimal Care Pathway for TAVI
NCT07343674 ·Status: RECRUITING
-
Prizvalve® Transcatheter Valve-in-Valve Implantation Exploratory Study
NCT05652062 ·Status: RECRUITING ·Phase: NA
-
Short-term Clinical Follow-up of the Vascular Closure Device MANTATM in Minimally Invasive Cardiac Surgery
NCT04802200 ·Status: COMPLETED
-
The CONFORMAL Early Feasibility Study
NCT03616028 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
CryoValve SG Pulmonary Human Heart Valve Post Clearance Study
NCT01092442 ·Status: COMPLETED
-
Evaluation of Endothelial Dysfunction During Aortic Valvular Replacement by Bioprosthesis With and Without Extracorporeal Circulation
NCT03135496 ·Status: COMPLETED
-
PERCEVAL S Valve Clinical Study for Chinese Registration
NCT03481387 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Investigation of a Transcatheter Tricuspid Valved Stent Graft in Patients With Carcinoid Heart Disease
NCT05064514 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Comparison of Sutureless Vs. Standard Biological Prostheses for Surgical Aortic Valve Replacement
NCT03965065 ·Status: UNKNOWN ·Phase: NA
-
Safety and Feasibility of the Transcatheter Tricuspid Valve Repair System (Trialign)
NCT04936802 ·Status: UNKNOWN ·Phase: NA
-
Prizvalve Pro™ Transcatheter Aortic Valve Replacement Study
NCT05864456 ·Status: RECRUITING ·Phase: NA
-
A Study to Evaluate the Safety and Performance of LuX-Valve Plus System for Tricuspid Replacement
NCT05436028 ·Status: COMPLETED ·Phase: NA
-
Cingularbio® Heart Valve Clincial Study
NCT02755220 ·Status: COMPLETED ·Phase: NA
-
Prospective Evaluation of Prognosis of Pci Patients Using Network Data in SHengjing Hospital
NCT02667548 ·Status: UNKNOWN
-
Prizvalve Transcatheter Aortic Valve in Failing Bioprosthetic Valves
NCT07122050 ·Status: NOT_YET_RECRUITING ·Phase: NA