User Satisfaction of Customised 3D Printed Ankle-Foot Orthosis in Comparison to Thermoformed Ankle-Foot Orthosis for Patients With Neurological Conditions: A Preliminary Study
NCT05122949 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 5
Last updated 2021-11-17
Summary
Study Design and Subject Recruitment: This was a cross-sectional study in a single centre outpatient setting at the Foot Care and Limb Design Centre, Tan Tock Seng Hospital. As this was a proof-of-concept clinical trial for the introduction of 3D printed AFOs as a patient service, only 5 subjects were recruited based on consecutive sampling.
Interventions: Thermoformed AFOs moulded over the subject's lower limb plaster model served as the control intervention. The plaster models were rectified by an orthotist with over 20 years of experience and the AFO design was determined according to the subject's clinical presentation and needs. The AFOs were manufactured from 4 - 5mm thick homopolymer polypropylene. 3D printed AFOs served as the treatment intervention. It was fabricated through 3D scanning with an Artec Eva 3D scanner (Artec 3D, Luxembourg, Luxembourg) and an adjustable Perspex glass foot plate, CAD modelling with the OrtenShape software (Proteor, Saint-Apollinaire, France), and printed using fused deposition modelling with the Fortus 450mc (Stratasys, Minnesota, United States). The 3D printed AFO is printed of Polyamide Nylon-12 material in the same thickness as the thermoformed AFO. There were no blinding procedures as both interventions were distinctly different and it is not possible to blind subjects with daily use of the AFOs.
Trial Schedule: A thermoformed and a 3D printed AFO were fitted to each subject in a single session. The QUEST survey was administered post-fitting. Subjects brought home both AFOs and were instructed to wear them during ambulation, alternating between the AFOs daily. Subjects returned for follow-up at 3 weeks and 6 weeks post-fitting for necessary adjustments and the administration of the QUEST surveys was repeated for each AFO.
Conditions
- Stroke
- Spinal Cord Injuries
- Nerve Palsy
Interventions
- DEVICE
-
3D Printed Ankle-Foot Orthosis
3D Printed (Fused Deposition Modelling) Ankle-Foot Orthosis with Polyamide Nylon-12 material
- DEVICE
-
Thermoformed Ankle-Foot Orthosis
Thermoformed Ankle-Foot Orthosis with homopolymer polypropylene
Sponsors & Collaborators
-
Tan Tock Seng Hospital
lead OTHER
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 21 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2017-11-03
- Primary Completion
- 2018-08-22
- Completion
- 2018-08-22
Countries
- Singapore
Study Locations
More Related Trials
-
Effectiveness of Specifically Optimized Off-the-counter Foot Orthosis for the Subtle Cavus Foot
NCT04941469 ·Status: COMPLETED ·Phase: NA
-
Comparison of 3D Printed Foot Orthoses With Prefabricated Foot Orthoses
NCT05896917 ·Status: COMPLETED ·Phase: NA
-
Comparing Active and Passive Ankle-foot Prostheses
NCT01684501 ·Status: COMPLETED
-
Contribution of an Off-the-shelf Carbon Ankle Foot Orthosis (AFO) in the Management of Walking Functional Impairment
NCT05131399 ·Status: RECRUITING ·Phase: NA
-
Evaluating User Satisfaction and Feasibility of a Remote Model for 3d Scanned and Printed Transtibial Prosthetic Sockets
NCT06361966 ·Status: COMPLETED ·Phase: NA
-
Ankle-foot Orthoses for Peripheral Artery Disease
NCT02280200 ·Status: COMPLETED ·Phase: NA
-
Smart Ankle-Foot Orthosis to Improve Stroke Outcomes: Smart AFO
NCT05619484 ·Status: RECRUITING ·Phase: PHASE2
-
AFO Prescription to Optimize Post-Stroke Function
NCT06692686 ·Status: RECRUITING ·Phase: NA
-
Comparison of Various Prosthetic Foot-Ankle Mechanisms
NCT05964855 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Evaluation of Foot Mechanical Information on Static Task and Locomotion
NCT05170750 ·Status: COMPLETED ·Phase: NA
-
The Effect of Customized Insoles on Biomechanics and Pain in Patients With Functional Flatfoot
NCT04381039 ·Status: COMPLETED ·Phase: NA
-
Comparison of the Functional Walking Outcomes of Two Settings of a Commercially Available AFO in Adult Stroke Patients
NCT02122783 ·Status: COMPLETED ·Phase: NA
-
The Effect of Sensorimotor Insoles on Gait Parameters in Adults With Flexible Flatfoot
NCT04125407 ·Status: UNKNOWN ·Phase: NA
-
3D Printed Guide in Ankle Arthrodesis
NCT03626935 ·Status: UNKNOWN ·Phase: NA
-
Comparing Digitally and Traditionally Made Ankle Foot Orthoses
NCT06828653 ·Status: RECRUITING ·Phase: NA
-
Improving Mobility in Peripheral Artery Disease Using an Ankle Foot Orthosis
NCT02902211 ·Status: COMPLETED ·Phase: NA
-
Study on a Prosthetic Foot With Adjustable Heel Height
NCT07214493 ·Status: RECRUITING ·Phase: NA
-
Effects of Fatigue and Foot Orthoses on Lower Extremity EMG and Biomechanics for Individuals With Flat Foot
NCT03842241 ·Status: COMPLETED
-
3D-Printed Personalized Metal Implant in Surgical Treatment of Ankle Bone Defects
NCT03185286 ·Status: UNKNOWN ·Phase: NA
-
Multi-layer Insoles for a Patient-specific Approach to Shear and Pressure Reduction in Diabetes-related Foot Ulcer
NCT01844479 ·Status: COMPLETED ·Phase: NA
-
Product Information Analysis and Clinical Verification - Clinical Verification of New Smart Health Medical Shoes/Insoles
NCT07298629 ·Status: RECRUITING ·Phase: NA
-
Effectiveness of Frontal Plane Adaptability in a Novel Foot Prosthesis
NCT06214026 ·Status: RECRUITING ·Phase: NA
-
Identifying the Optimal Dynamic Ankle-Foot Orthosis Bending Stiffness for Individuals Post-Stroke
NCT06304519 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Effect of an Ankle Foot Orthoses for Ambulatory Function
NCT01336517 ·Status: COMPLETED
-
Use of Plantar Flexion Resistant Ankle-Foot Orthosis in Stroke Patients With Genurecurvatum Gait
NCT06394635 ·Status: COMPLETED