Extracorporeal CO2 Removal in Acute Exacerbation of COPD Not Responding to Non-Invasive Ventilation

NCT04882410 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 56

Last updated 2021-05-12

No results posted yet for this study

Summary

Background: Acute exacerbation of chronic obstructive pulmonary disease (ae-COPD) has a gold standard treatment: non-invasive ventilation (NIV). However, this treatment sometime fails, and an invasive mechanical ventilation (IMV) is required. The extracorporeal CO₂ removal (ECCO₂R) device can be an alternative to intubation. The aim of the study is to evaluate ECCO₂R efficiency and safety and enlighten ECCO₂R benefit/risk compared to IMV.

Methods: Successive ae-COPD patients for whom NIV failed were retrospectively analyzed during two periods: before and after the ECCO₂R device implementation in our ICU in 2015. We considered the before period as standard of care and patients were treated with IMV. The ECCO₂R device was a pump-driven veno-venous system (Xenios AG).

Conditions

  • COPD Exacerbation Acute

Sponsors & Collaborators

  • Centre Hospitalier de Saint-Denis

    lead OTHER

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2010-01-31
Primary Completion
2020-02-29
Completion
2020-02-29