A Comparison Between Lumen-apposing Metal Stent and Double-pigtail Plastic Stents for Treatment of Walled-off Necrosis
NCT04876235 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 50
Last updated 2023-02-21
Summary
Walled-off necrosis (WON) is defined as an encapsulated collection of solid and liquid necrotic material that is usually formed 4 weeks after an episode of acute necrotizing pancreatitis. As the advances in endoscopic techniques and accessories, Endoscopic ultrasound (EUS)-guided transluminal drainage has evolved to become the treatment of choice for symptomatic pancreatic walled-off necrosis (WON). This article aims to compare the efficacy and safety of a double mushroom head metal stent and a double pigtail plastic stent in the treatment of encapsulated necrosis of the pancreas.
Conditions
- Walled-off Necrosis
Interventions
- PROCEDURE
-
endoscopic ultrasound
All patients were implanted with stents(DPPS or LAMS)under the EUS
- DEVICE
-
lumen-apposing metal stent
In the LAMS group, patients were stented with LAMS
- DEVICE
-
double-pigtail plastic stents
In the DPPS group, patients were stented with DPPS
Sponsors & Collaborators
-
First People's Hospital of Hangzhou
lead OTHER
Principal Investigators
-
Xiaofeng Zhang, M.S · First People's Hospital of Hangzhou
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2021-05-01
- Primary Completion
- 2022-12-31
- Completion
- 2022-12-31
Countries
- China
Study Locations
More Related Trials
-
A Prospective Randomized Multi-center Study for Efficacy of Metallic Biliary Stent Compared to Plastic Stent in Patients Receiving Neoadjuvant Chemotherapy for Resectable Pancreatic Cancer
NCT04911647 ·Status: UNKNOWN ·Phase: NA
-
Long-Term Outcomes of Different Stents for Benign Biliary Strictures Caused by Chronic Pancreatitis
NCT06981975 ·Status: COMPLETED
-
Study of Gastroduodenal Metallic Stent vs Gastrojejunostomy
NCT02784470 ·Status: UNKNOWN ·Phase: PHASE3
-
Novel Stent Placement Technique for Intestinal Stenosis Assisted by an Ultrafine Endoscope
NCT04494919 ·Status: COMPLETED
-
Comparison of Duodenal Stenting vs Transpyloric and Duodenal Stenting for Malignant Obstruction
NCT03125148 ·Status: COMPLETED ·Phase: NA
-
WallFlex Biliary Fully Covered (FC) Chronic Pancreatitis Study
NCT01543256 ·Status: COMPLETED ·Phase: NA
-
Comparison Between Transpapillary and Suprapapillary Metal Stent
NCT04503291 ·Status: UNKNOWN ·Phase: NA
-
WallFlex Pancreatic Metal Stent for Pancreatic Duct Strictures
NCT02802020 ·Status: COMPLETED ·Phase: NA
-
Covered Metallic Stent and Benign Colonic Strictures
NCT01570114 ·Status: COMPLETED
-
RCT Steel (Wallstent®) vs Nitinol (Wallflex®) Bile Duct Stent for Palliation of Malignant Obstruction
NCT00980889 ·Status: COMPLETED ·Phase: PHASE4
-
Outcome Study of Double Bare Stent for Malignant Gastric Outlet Obstruction
NCT02156505 ·Status: UNKNOWN ·Phase: PHASE4
-
Double Pig Tail Stent-assisted Fixation of Fully Covered Metal Stents for the Treatment of Benign Duodenal Strictures
NCT06736301 ·Status: RECRUITING ·Phase: NA
-
A Comparison of a Fully Covered Self-expandable Metal Stent With an External Anchoring Plastic Stent and Uncovered Stent
NCT05220475 ·Status: UNKNOWN ·Phase: NA
-
Winged Perimeter Versus Traditional Plastic Biliary Stent for Malignant Bile Duct Obstruction
NCT01514214 ·Status: COMPLETED ·Phase: NA
-
Suspended Overlength Biliary Stents Preventing Duodenobiliary Reflux in Patients With Biliary Stricture
NCT03310554 ·Status: UNKNOWN ·Phase: NA
-
Covered Self-expandable Metallic Stents Insertion Using Clips and Suture Materials for Preventing Migration
NCT02193789 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Use of Metal Stents as Part of the Treatment of Benign Biliary Strictures
NCT01238900 ·Status: COMPLETED
-
Partially Covered Metal Stents Efficacy in Biliary Drainage of Malignant Extra-hepatic Biliary Obstruction
NCT04431427 ·Status: UNKNOWN ·Phase: NA
-
Single Versus Multiple Plastic Stents in Malignant Distal Bile Duct Obstruction
NCT03849859 ·Status: TERMINATED ·Phase: NA
-
Comparing Covered Self-expandable Metallic Stent (SEMS) Above/Across the Sphincter of Oddi
NCT01041612 ·Status: COMPLETED ·Phase: PHASE4
-
Comparison of a Plastic Stent Without Central Lumen With Self Expandable Metal Stents in Patients With Malignant Distal Biliary Obstruction
NCT01063634 ·Status: UNKNOWN
-
Plastic Stenting Versus Retrievable Metallic Stenting for Biliary Anastomotic Stricture After Liver Transplantation
NCT04144504 ·Status: UNKNOWN ·Phase: NA
-
Covered Metal Stent for Benign Biliary Stricture Caused by Chronic Pancreatitis
NCT01929538 ·Status: UNKNOWN ·Phase: NA
-
Radiation Stent Versus Self-expanding Metallic Stents (SEMS) for Palliative Treatment of Malignant Biliary Stricture
NCT01320241 ·Status: COMPLETED ·Phase: PHASE2
-
Endoscopic Scissors Cutting Nasobiliary Duct VS Bilateral Plastic Stent
NCT06106750 ·Status: RECRUITING ·Phase: NA